SGM9127 4-Channel, 5th-Order, Standard Definition Video Filter
... signals, this device is ideal for a wide range of television and set-top box applications. SGM9127 offers 6dB gain rail-to-rail output driver and 5th-order output reconstruction filter on all four channels. It has 8MHz -3dB bandwidth and 35V/µs slew rate. SGM9127 provides improved image quality comp ...
... signals, this device is ideal for a wide range of television and set-top box applications. SGM9127 offers 6dB gain rail-to-rail output driver and 5th-order output reconstruction filter on all four channels. It has 8MHz -3dB bandwidth and 35V/µs slew rate. SGM9127 provides improved image quality comp ...
1 - gtbit
... c. DC dynamic braking d. All of above 37. The speed of an IM can be varied by variable frequency supply from a static power converter. A simultaneous voltage variation is also effected in order to a. To avoid saturation and provide optimum torque capability b. To decrease the torque pulsations c. To ...
... c. DC dynamic braking d. All of above 37. The speed of an IM can be varied by variable frequency supply from a static power converter. A simultaneous voltage variation is also effected in order to a. To avoid saturation and provide optimum torque capability b. To decrease the torque pulsations c. To ...
Input Offset Voltage
... Voltage clipping is the distortion in the op-amp output caused by the limiting of the maximum output voltage of the op-amp. Apply a 1kHz signal to the input of the circuit above. Set the difference values of the supply voltage, adjust the magnitude of the input signal that we have a maximum swing in ...
... Voltage clipping is the distortion in the op-amp output caused by the limiting of the maximum output voltage of the op-amp. Apply a 1kHz signal to the input of the circuit above. Set the difference values of the supply voltage, adjust the magnitude of the input signal that we have a maximum swing in ...
330R 1/8 DIN Process Monitor and Indicator
... • Square root linearization results in accurate measurement from flow transmitters with nonlinear outputs, saving the expense of a separate square root extractor. • User-definable 15-point linearization allows customized linearization of the input signal for highly accurate measurements in engineeri ...
... • Square root linearization results in accurate measurement from flow transmitters with nonlinear outputs, saving the expense of a separate square root extractor. • User-definable 15-point linearization allows customized linearization of the input signal for highly accurate measurements in engineeri ...
Xonar Essence One
... Even brighter than the above combination, and more detailed with less but tighter bottom sound ...
... Even brighter than the above combination, and more detailed with less but tighter bottom sound ...
UM1470
... blocking voltage is selected to increase robustness against input surge pulse. The EMI filter is based on a π filter (C10, C2, L1) and the possibility to place an input foil capacitor may also be an option. This capacitor is not mandatory in order to satisfy EMI limits (see Figure 9), but it can be ...
... blocking voltage is selected to increase robustness against input surge pulse. The EMI filter is based on a π filter (C10, C2, L1) and the possibility to place an input foil capacitor may also be an option. This capacitor is not mandatory in order to satisfy EMI limits (see Figure 9), but it can be ...
Presentation 3 File
... Good practice start up with coarse grid and • progressively refine it as your design need. Refinement should be made in ...
... Good practice start up with coarse grid and • progressively refine it as your design need. Refinement should be made in ...
LT1116 - 12ns, Single Supply Ground-Sensing Comparator
... between the input and the negative rail, speeds up recovery from negative overdrive by preventing the substrate diode from turning on. The zero crossing detector in Figure 1 demonstrates the use of a fast clamp diode. Recovery, from 500mV overdrive below V –, for this circuit is approximately 18ns. ...
... between the input and the negative rail, speeds up recovery from negative overdrive by preventing the substrate diode from turning on. The zero crossing detector in Figure 1 demonstrates the use of a fast clamp diode. Recovery, from 500mV overdrive below V –, for this circuit is approximately 18ns. ...
A Soft-Switching DC/DC Converter with High Voltage Gain
... converter reduces switching loss of active power switches and raises the conversion efficiency by using zero voltage switching (zvs) and zero current switching (zcs) techniques. This paper provides the effective solution for reverse recovery problem of the output rectifier by controlling the rate of ...
... converter reduces switching loss of active power switches and raises the conversion efficiency by using zero voltage switching (zvs) and zero current switching (zcs) techniques. This paper provides the effective solution for reverse recovery problem of the output rectifier by controlling the rate of ...
ENEE 244 - Ece.umd.edu
... 8. The outputs of a 3-to-8 decoder are connected in order to the inputs of an 8-to-1 MUX. The inputs of the decoder are a,b and c; the select inputs of the MUX are d,e and f. What function does the 1-bit output of the MUX implement in terms of a,b,c,d,e and f? A decoder turns its ith output high if ...
... 8. The outputs of a 3-to-8 decoder are connected in order to the inputs of an 8-to-1 MUX. The inputs of the decoder are a,b and c; the select inputs of the MUX are d,e and f. What function does the 1-bit output of the MUX implement in terms of a,b,c,d,e and f? A decoder turns its ith output high if ...
Test Procedure for the NCL30051LEDGEVB Evaluation Board
... power source is able to measure these parameters accurately and is calibrated, the analyzer can be omitted. 3. Digital volt/amp meters to measure output current and voltage to the electronic load (internal meters in electronic load are acceptable if calibration is correct). 4. An electronic load cap ...
... power source is able to measure these parameters accurately and is calibrated, the analyzer can be omitted. 3. Digital volt/amp meters to measure output current and voltage to the electronic load (internal meters in electronic load are acceptable if calibration is correct). 4. An electronic load cap ...
Current Sourcing ZCS Magnetron Driver for Low Input Voltage
... For every practical design one needs to select the optimal combination of the resonant inductor, capacitor, and transformer ratio. One possible goal of the optimization may be keeping the losses as low as possible. To compare the losses at various operating conditions, the ratio of the output averag ...
... For every practical design one needs to select the optimal combination of the resonant inductor, capacitor, and transformer ratio. One possible goal of the optimization may be keeping the losses as low as possible. To compare the losses at various operating conditions, the ratio of the output averag ...
Designing Flyback Converters Using Peak-Current-Mode
... 22kΩ (typical values), to use the full range of available COMP voltage. U3 is a low-voltage adjustable shunt regulator with a 1.24V reference voltage. Calculate R LED using Equation 48, based on output voltage VOUT . R LED = 400 × CTR × (VOUT - 2.7)Ω ...
... 22kΩ (typical values), to use the full range of available COMP voltage. U3 is a low-voltage adjustable shunt regulator with a 1.24V reference voltage. Calculate R LED using Equation 48, based on output voltage VOUT . R LED = 400 × CTR × (VOUT - 2.7)Ω ...
DM32711716
... The modulator switches the valves ON and OFF, following a pre-established template. Particularly, this template could be a sinusoidal waveform of voltage (voltage source, current controlled PWM rectifier) or current (voltage source, current controlled PWM rectifier). For example, for a voltage contr ...
... The modulator switches the valves ON and OFF, following a pre-established template. Particularly, this template could be a sinusoidal waveform of voltage (voltage source, current controlled PWM rectifier) or current (voltage source, current controlled PWM rectifier). For example, for a voltage contr ...
Action PAK® AP4003
... 2. Rotate the pot fully CW or to the desired maximum point and observe that the Green LED is on or flashing. Push the CAL button and hold for more than 4 seconds. The Yellow and Red LEDs should be on. Push the CAL button momentarily and the Yellow and Green LEDs will be on. (From this point on, you ...
... 2. Rotate the pot fully CW or to the desired maximum point and observe that the Green LED is on or flashing. Push the CAL button and hold for more than 4 seconds. The Yellow and Red LEDs should be on. Push the CAL button momentarily and the Yellow and Green LEDs will be on. (From this point on, you ...
H-Bridge inverter circuit class notes
... EE462L, Spring 2014 H-Bridge Inverter (partially pre-fall 2009 version) ...
... EE462L, Spring 2014 H-Bridge Inverter (partially pre-fall 2009 version) ...
Objectives PHY 252 Spring 2011 Practical Lab #1 Ohm’s Law
... V = voltage applied across the circuit and has SI units of volts (V) I = current flowing through the circuit and has SI units of amperes (A) R = resistance of the circuit and has SI units of ohms (Ω) ...
... V = voltage applied across the circuit and has SI units of volts (V) I = current flowing through the circuit and has SI units of amperes (A) R = resistance of the circuit and has SI units of ohms (Ω) ...
AMS5105 数据手册DataSheet 下载
... Dropout Voltage: The input-output voltage differential at which the circuit stops to regulate against further reduction in input voltage. Measured when the output voltage has dropped 100mV from the nominal voltage obtained at 1V input, dropout voltage is dependent upon load current and junction temp ...
... Dropout Voltage: The input-output voltage differential at which the circuit stops to regulate against further reduction in input voltage. Measured when the output voltage has dropped 100mV from the nominal voltage obtained at 1V input, dropout voltage is dependent upon load current and junction temp ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.