• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Real Time Implementation of PI and PID Controlled Cascaded H
Real Time Implementation of PI and PID Controlled Cascaded H

... (+Vdc,+2Vdc,+3Vdc,+4Vdc), and negative(−Vdc,-2Vdc,3Vdc,-4Vdc) supply dc voltage (assuming that Vdc is the supply voltage). By using the carrier frequency and switching functions, the harmonic components of the output voltage are determined. Therefore, their reduction of harmonics is just restricted ...
geo direct pwm amplifier
geo direct pwm amplifier

... control-style equivalent of the Power Block. In other uses, the GEO Drive can be controlled in torque, velocity or even position modes. It can accept several styles of position feedback, including single or dual quadrature encoders, sinusoidal with built-in interpolation (x1024) in the GEO, resolver ...
Solar Car Data Collection System
Solar Car Data Collection System

Aalborg Universitet Phase Standalone DG System
Aalborg Universitet Phase Standalone DG System

... multi-loop control strategy for three-phase inverter-based islanded DG systems under unbalanced and/or nonlinear load conditions. The proposed control methodology utilizes the parallel virtual resistance (PVR)-based active damping (AD) method for the islanded DG system using an extra feedback capaci ...
PDF
PDF

... control of the BLDC motor by controlling the dc link voltage of the voltage source inverter (VSI) is used with a single voltage sensor. This facilitates the operation of VSI at fundamental frequency switching by using the electronic commutation of the BLDC motor which offers reduced switching losses ...
Power Distribution
Power Distribution

... For transmitting large power over large distances through transmission lines voltage level is increased for less power losses. All transmission and distribution system are 3-phase system. Transmission lines and feeders are 3 phase 3 wire circuit while distribution lines are 3 phase 4 wire circuit. T ...
Critical load protection from the world`s largest three phase UPS
Critical load protection from the world`s largest three phase UPS

... topology (the only recognized true “on-line” topology for use in high reliability applications) uses the rectifier & inverter to isolate devices on the UPS output from the dangers of raw utility power. Other conversion topologies allow poor power conditions, such as low voltage surges, to travel thr ...
The proposed switched-coupled-inductor converter is a
The proposed switched-coupled-inductor converter is a

DMM
DMM

Sizing a rectifier-based power supply
Sizing a rectifier-based power supply

... value. This is where the capacitor, C, and the LM78XX voltage regulator of Figure 1 become important. A typical voltage regulator requires that the voltage on the input pin maintain a certain margin above the regulated output voltage. This is typically in the range of 2.5 to 3 V and for the LM7805, ...
CM6901
CM6901

SG1577A Dual Synchronous DC/DC Controller SG1577A — Dual Sync
SG1577A Dual Synchronous DC/DC Controller SG1577A — Dual Sync

... Place the PWM power stage components first. Mount all the power components and connections in the top layer with wide copper areas. The MOSFETs of buck, inductor, and output capacitor should be as close to each other as possible to reduce the radiation of EMI due to the high-frequency current loop. ...
TJ49150 1.5A Very Low Input / Output Voltage Ultra Low Dropout
TJ49150 1.5A Very Low Input / Output Voltage Ultra Low Dropout

Evaluates: MAX1692 MAX1692 Evaluation Kit General Description Features
Evaluates: MAX1692 MAX1692 Evaluation Kit General Description Features

File
File

... wire being ‘installed.’ ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

User`s Guide Model DVA30
User`s Guide Model DVA30

Safety Messages Hazardous High Voltage
Safety Messages Hazardous High Voltage

Connector Amplifier For Proportional Valves
Connector Amplifier For Proportional Valves

... The Economy Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20 mA). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. Maximum ...
RLP-‐1048 Heavy Duty AC to DC Power Supply
RLP-‐1048 Heavy Duty AC to DC Power Supply

Lecture 7 Overview - University of Delaware
Lecture 7 Overview - University of Delaware

产品摘要
产品摘要

... orientation, activity, and wake-up algorithms. Kionix’s XAC sensor provides outstanding stability with a market-leading combination of improved shock, reflow, and thermal performance. The KX022 also offers accelerometer outputs with 16-bit resolution for greater precision. Userselectable parameters ...
Fluke DP120 Differential Probe Instruction PDF
Fluke DP120 Differential Probe Instruction PDF

... floating high voltage measurements. The probe can be used on electronic high-power converters, motor speed controls, switch mode power supplies, and other high voltage circuits. ...
CKX150 Specifications
CKX150 Specifications

POWER PROTECTION
POWER PROTECTION

< 1 ... 938 939 940 941 942 943 944 945 946 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report