• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Transmission Solar PV Plant Data Request
Transmission Solar PV Plant Data Request

CMD235C4 - Custom MMIC
CMD235C4 - Custom MMIC

... ► Low loss broadband performance ► High isolation ► Non-reflective design ► Integrated 3:8 TTL decoder ► Pb-free RoHs compliant 4x4 SMT package ...
40VIN /40VOUT 5A Constant-Current, Constant
40VIN /40VOUT 5A Constant-Current, Constant

results of the optinos project – deficits and unsureness in test
results of the optinos project – deficits and unsureness in test

... disturbance source of the inverter can deliver its short circuit current which can be measured alternatively with a current probe on a single inverter line or as voltage drop above the network impedance using the RF output port of the AMN. The network has quite low impedances even at 50Hz or 60Hz be ...
Panasonic B Series AC Servo Motor Driver Manual
Panasonic B Series AC Servo Motor Driver Manual

... ♦ Capacity of power rectifying circuit capacitor decreases due to secular change. To prevent secondary damage caused by failure, it is recommended to replace the capacitor every five years. For replacement, contact us or our authorized dealer. ♦ To prevent electric shock, install cover onto the LED ...
Aalborg Universitet
Aalborg Universitet

automated smart sowing machine for port trays (agri robot)
automated smart sowing machine for port trays (agri robot)

Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current
Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current

... Be sure to connect the positive lead from the power supply to the positive terminal of the ammeter. To connect multiple resistors (loads), use alligator clips to fasten them together in series. Your final connection should be to the negative terminal of the power supply. IF YOU SEE OR SMELL SMOKE, ( ...
Si3402-C - Silicon Labs
Si3402-C - Silicon Labs

FSDH0265RN, FSDM0265RN
FSDH0265RN, FSDM0265RN

... mode PWM feedback, these are not enough to protect the FPS when a secondary side diode short or a transformer pin short occurs. In addition to start-up, soft-start is also activated at each restart attempt during auto-restart and when restarting after latch mode is activated. The FPS has an internal ...
Assembly instruction - Inter-Lux
Assembly instruction - Inter-Lux

Transistors - The Common Base Amplifier 1430 Experiment 7
Transistors - The Common Base Amplifier 1430 Experiment 7

... This means divide the output current by the input current. b) Use the values you recorded in steps 10 and 11 and calculate the current gain. c) Record this calculation in your experiment/lab book. ...
fuzzy control of shoot through time of single stage
fuzzy control of shoot through time of single stage

Active Harmonic Filtering Solutions Catalogue
Active Harmonic Filtering Solutions Catalogue

Linearity Improvement Analysis for PAs at mm- Wave Frequencies Joe Valliarampath Graduate
Linearity Improvement Analysis for PAs at mm- Wave Frequencies Joe Valliarampath Graduate

DESCRIPTION OF SUPER SWITCH OPERATION The Super switch
DESCRIPTION OF SUPER SWITCH OPERATION The Super switch

... limits.If the preferred source falls outside the acceptable limits, the Superswitch is designed to transfer the output load to the other “alternate” input source, as long as the alternate source is within acceptable voltage limits and is synchronized with the preferred source within the selected pha ...
Power-monitoring units Power Meter Series 700
Power-monitoring units Power Meter Series 700

... With its large display, you can monitor all three phases and neutral at the same time. The anti-glare display features large 11 mm high characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. The Power Meter Series 700 is available in four versio ...
TPS61175 SEPIC Design Application Report ...................................................................................... Design Example
TPS61175 SEPIC Design Application Report ...................................................................................... Design Example

... Note if L1a and L1b are closely coupled, the ripple current is divided between them and the required inductance is halved. In account for inductor tolerance, the designer selected the next closest standard value, which is 15 mH. When selecting an inductor, the two additional specifications are its D ...
PSPICE计算机仿真
PSPICE计算机仿真

... The initial voltage is positive at the left-most terminal of the capacitor, or bottom terminal if the part is rotated once. The initial current enters the left-most terminal of the inductor, or terminal of the inductor, or bottom terminal if the part is rotated once. ...
Assessment to Study of Voltage Unbalance Effects about Efficiency
Assessment to Study of Voltage Unbalance Effects about Efficiency

... system can be specified using two commonly used definitions. The first definition is widely used in European standards and is based on the Theory of Symmetrical Components. The second definition is used in USA and avoids the use of complex algebra. 2.1.1 IEC Definition The definition of voltage unba ...
DC-DC Converter Application Guidelines
DC-DC Converter Application Guidelines

Low Power Pulse Width Modulator
Low Power Pulse Width Modulator

... where VFWD is line voltage scaled by R1 and R2. Therefore, a changing line voltage will accomplish an immediate proportionate pulse width change without any action from the feedback amplifier. This will result in constant volt-second drive to the power transformer providing both international voltag ...
Principle of Boost Chopper Modes of operation of Boost chopper
Principle of Boost Chopper Modes of operation of Boost chopper

NCP1532GEVB NCP1532 Dual Output Step-down Converter Evaluation Board User's
NCP1532GEVB NCP1532 Dual Output Step-down Converter Evaluation Board User's

... This is the test point of the Power On Reset. This is an open drain output. This output is shutting down when each output voltages are less than 90% of their nominal values and goes high after 120 ms when active outputs are within regulation. ...
High Average Power, High Current Pulsed Accelerator
High Average Power, High Current Pulsed Accelerator

... square centimeters per pulse, without beam scanning, depending on the energy per unit volume required by the target to achieve the desired internal effects. The required beam accelerating potential, for any of the above systems, is set by the desired energy penetration in the target material. The be ...
< 1 ... 871 872 873 874 875 876 877 878 879 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report