Technical Teaching Equipment
... Nominal power: 370 W. Nominal voltage: 3x 230/400 VAC Δ/Y. Frequency: 50/60 Hz. Number of poles: 2. RPM: 2730 r.p.m. Nominal current: 1,67/ 0,97 A. • All necessary cables to realize the practical exercises are included. Cables and accessories, for normal operation. Manuals: This unit is supplied wit ...
... Nominal power: 370 W. Nominal voltage: 3x 230/400 VAC Δ/Y. Frequency: 50/60 Hz. Number of poles: 2. RPM: 2730 r.p.m. Nominal current: 1,67/ 0,97 A. • All necessary cables to realize the practical exercises are included. Cables and accessories, for normal operation. Manuals: This unit is supplied wit ...
IXAN0068 - IXYS Corporation
... cannot be used when computing its thermal limitations in linear applications. For this case, one must use its SOA rating of 240W at VDS = 800V, ID = 0.3A and TC = 90oC. Assuming a 20% safety margin, this reduces its allowable power dissipation to 192W. The maximum output power for the power supply i ...
... cannot be used when computing its thermal limitations in linear applications. For this case, one must use its SOA rating of 240W at VDS = 800V, ID = 0.3A and TC = 90oC. Assuming a 20% safety margin, this reduces its allowable power dissipation to 192W. The maximum output power for the power supply i ...
Power Quality issues and its improvement in wind
... be of large capacity, up to 2 MW, feeding into distribution network with high source impedance, particularly with customers connected in close proximity [1]. In case of fixedspeed wind turbine operation, all the fluctuation in the wind speed are transmitted as fluctuations in the mechanical torque, ...
... be of large capacity, up to 2 MW, feeding into distribution network with high source impedance, particularly with customers connected in close proximity [1]. In case of fixedspeed wind turbine operation, all the fluctuation in the wind speed are transmitted as fluctuations in the mechanical torque, ...
Test systems for -compliance
... Because of their technology, switched power sources are highly efficient, more compact and even cheaper than linear power sources. Therefore they are quite often being used in compliance test systems for harmonics and flicker. They can supply the maximum current even under reactive loads with low or ...
... Because of their technology, switched power sources are highly efficient, more compact and even cheaper than linear power sources. Therefore they are quite often being used in compliance test systems for harmonics and flicker. They can supply the maximum current even under reactive loads with low or ...
References - Lighting Fixture Design
... • If LED system works at more than 60V, protection will be required to prevent user contact – check by measuring touch current if apprpriate • Test the electrical strength of all safety barriers • Above 60V dc (25V ac rms), the LED assembly will need a minimum of basic insulation • Series connected ...
... • If LED system works at more than 60V, protection will be required to prevent user contact – check by measuring touch current if apprpriate • Test the electrical strength of all safety barriers • Above 60V dc (25V ac rms), the LED assembly will need a minimum of basic insulation • Series connected ...
Electrical Installations Level 3 - Pearson Schools and FE Colleges
... of the power system. The wound-rotor motor is also appropriate for high-inertia loads having a long acceleration time. This is because you can control the speed, torque and resulting heating of the wound-rotor motor. This control can be automatic or manual. It is also effective with high-slip loads ...
... of the power system. The wound-rotor motor is also appropriate for high-inertia loads having a long acceleration time. This is because you can control the speed, torque and resulting heating of the wound-rotor motor. This control can be automatic or manual. It is also effective with high-slip loads ...
EE-36 - International Journal of Advance Research and Innovation
... the rated values. The simulation results are shown in Figure 6. According to the simulation results, when amplitude of voltage drop is smaller, the DVR can be used to compensate the voltage drop, and load side voltage can be stabilize to the rated value. But when amplitude of voltage drops seriously ...
... the rated values. The simulation results are shown in Figure 6. According to the simulation results, when amplitude of voltage drop is smaller, the DVR can be used to compensate the voltage drop, and load side voltage can be stabilize to the rated value. But when amplitude of voltage drops seriously ...
STN0214
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Sliding Mode Control and Stability Analysis of a DC
... penalizes the second-stage DC-DC converter [1]. This DC-DC converter not only has to meet the characteristics demanded by the load, but also must process energy with high efficiency, high reliability, high power density and low cost [2]. In its simplest terms, the operation of a DC-DC converter can ...
... penalizes the second-stage DC-DC converter [1]. This DC-DC converter not only has to meet the characteristics demanded by the load, but also must process energy with high efficiency, high reliability, high power density and low cost [2]. In its simplest terms, the operation of a DC-DC converter can ...
Digital Multimeter
... meter offers nine different measurement functions plus features that are usually found in much more expensive and larger meters. The digital display is oversized with large digits and unit icons in the display. In spite of its size, this meter is fully safety rated to CAT III 300 V, CAT II 600 V and ...
... meter offers nine different measurement functions plus features that are usually found in much more expensive and larger meters. The digital display is oversized with large digits and unit icons in the display. In spite of its size, this meter is fully safety rated to CAT III 300 V, CAT II 600 V and ...
M4300-PM - Panamax!
... Total Outlets...............................................................................................................9 outlets Always-On Outlets.....................................................................................................0 outlets Switched Outlets...................... ...
... Total Outlets...............................................................................................................9 outlets Always-On Outlets.....................................................................................................0 outlets Switched Outlets...................... ...
Slide 1
... Thyristor Converters: Inverter Mode (Vd is negative) • Average value of vd is negative for 90o90o • Inverter mode of operation is possible bec ...
... Thyristor Converters: Inverter Mode (Vd is negative) • Average value of vd is negative for 90o90o • Inverter mode of operation is possible bec ...
GD3310901094
... located to reduce active power losses and as well as improvement of voltage profile in normal, over load and contingency conditions using Partial Swarm Optimization Technique. The simulations are performed on an IEEE 30-bus system and results are presented. ...
... located to reduce active power losses and as well as improvement of voltage profile in normal, over load and contingency conditions using Partial Swarm Optimization Technique. The simulations are performed on an IEEE 30-bus system and results are presented. ...
S8VE (60/90/120/180/240-W Models)
... increase the long-term reliability of the Product. Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. • When cutting out holes for mounting, make sure that cuttings do not enter th ...
... increase the long-term reliability of the Product. Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. • When cutting out holes for mounting, make sure that cuttings do not enter th ...
International Journal of Computer Science and Intelligent
... capacitors are installed in Vicinity of large inductive load e.g. Induction motors and transformers etc., and improve the load circuit power factor to improve the system or devises efficiency. Power Factor improvement by static capacitor phase advancer and synchronous-condenser 3. Phase advancer Pha ...
... capacitors are installed in Vicinity of large inductive load e.g. Induction motors and transformers etc., and improve the load circuit power factor to improve the system or devises efficiency. Power Factor improvement by static capacitor phase advancer and synchronous-condenser 3. Phase advancer Pha ...
Time Electronics
... In source mode the range can be user programmed to any value between 0mA and 50mA, or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set giving a span of 40mA. Measure mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ...
... In source mode the range can be user programmed to any value between 0mA and 50mA, or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set giving a span of 40mA. Measure mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ...
CAP200DG CAPZero-2 - Mouser Electronics
... discharged. As such CAP200DG can be safely used at low input voltages such as the common industrial 18 VAC and 24 VAC supply rails while retaining X capacitor discharge when the AC source is disconnected. ...
... discharged. As such CAP200DG can be safely used at low input voltages such as the common industrial 18 VAC and 24 VAC supply rails while retaining X capacitor discharge when the AC source is disconnected. ...
PDF
... In this paper a high efficient photovoltaic system is proposed for onboard ship applications which convert the lower voltage obtained from solar modules to higher voltage required by the ship service loads. In a typical photovoltaic system only step-up /boost converter is used due to which the conve ...
... In this paper a high efficient photovoltaic system is proposed for onboard ship applications which convert the lower voltage obtained from solar modules to higher voltage required by the ship service loads. In a typical photovoltaic system only step-up /boost converter is used due to which the conve ...
Variable-frequency drive
A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.