• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ZXBM5210 Description Pin Assignments
ZXBM5210 Description Pin Assignments

... motor mechanical and coil design parameters and not limited by the output capability of the device. If voltage at VDD is lower than the nominal motor voltage, both start-up PWM duty and minimum running PWM duty required will be higher. ...
Generation and Load Interconnection Standard
Generation and Load Interconnection Standard

... Figure 3-2: Generator Frequency Trip Setting ...................................................... 16 ...
11. DC/AC Inverters (optional) - CleanEnergy Solutions International
11. DC/AC Inverters (optional) - CleanEnergy Solutions International

... The solar (PV) system referred to in this document is perceived to be the dominant type of system in the local market in the next decade or so. Typically called the solar home system (SHS), it operates at a nominal voltage of 12 V DC. An SHS intends to provide the user with a convenient means of sup ...
Electronically Coupled Distributed Generation Modeling and Control
Electronically Coupled Distributed Generation Modeling and Control

... maintain unity power factor, and an outer loop to control reference DC voltage so as to remain at a voltage that extracts maximum power from the PV. The inverter switching technique is pulse width modulation (PWM),the switches operate at constant frequency which ...
722-4017-E00 MOP Analog Input Modules MOP-XXAI-X
722-4017-E00 MOP Analog Input Modules MOP-XXAI-X

... eliminate over/under tightening of cables ...
Xilinx DS108-1: XA9500XL Automotive CPLD Product Family
Xilinx DS108-1: XA9500XL Automotive CPLD Product Family

... The XA9500XL 3.3V CPLD Automotive XA product family is targeted for leading-edge, high-performance automotive applications that require either automotive industrial (–40°C to +85°C ambient) or extended (–40°C to +105°C ambient) temperature reconfigurable devices. ...
VME600(8) -1- (5,50)(-5,6)(12,12)(-12,2)(3.3,26) (
VME600(8) -1- (5,50)(-5,6)(12,12)(-12,2)(3.3,26) (

... P/N 94028-3 Behlman’s VME600 COTS power supply is a dual redundant rugged, low cost, highly reliable, switch mode unit built for high-end industrial and military applications to power work stations and VME card racks. The VME600 can accept a wide range of AC inputs and can supply a variety of DC out ...
Aatmesh_alicia_finalProject
Aatmesh_alicia_finalProject

1_Power_parts
1_Power_parts

unit 8 - WordPress.com
unit 8 - WordPress.com

Air Cooled Condensers
Air Cooled Condensers

... may become loose during shipment. Tightening of wire connections is the responsibility of the installing contractor. 2.5 Phase The air cooled condenser may be ordered as three phase but the individual fan motors are single phase and will only run in one direction. Check operation by placing a moment ...
AN-5052 Implementing the Physical Layer in a USB 2.0 Compliant System AN-
AN-5052 Implementing the Physical Layer in a USB 2.0 Compliant System AN-

... voltage USB controllers. Many USB controllers are no longer independent devices or even part of the transceiver but have been integrated into small line width ASICs. Many of these ASICs operate at very low voltages in the range of 1.8V which causes a potential problem when trying to communicate with ...
Laboratory 2: PV Module Current-Voltage Measurements Current (A)
Laboratory 2: PV Module Current-Voltage Measurements Current (A)

... hour of solar noon, and with the plane of array perpendicular to the sun’s rays. Cell temperature should be allowed to stabilize before being measured. During the test, the I-V curve data points should be taken as quickly as practical to minimize the effect of a change in irradiance level or a chang ...
Photologic - OPTEK Technology
Photologic - OPTEK Technology

... output options for the buffer designs (high logic level with light sensed and low logic level with no light sensed) and the inverter designs (low logic level with light sensed and high logic level with no light sensed. In addition there is a totem-pole output and open collector output configurations ...
A Proposed Broadband Power Line Communication System
A Proposed Broadband Power Line Communication System

... feeders, cap banks, switches, transformers and other elements can be viewed in their natural operating state. Baseline metrics are established, and performance deterioration identified and prioritized “way before the point of failure”. This can be used to determine a faulty insulator or a pending t ...
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

... The voltage monitoring relays CM-ESS.2 are designed for use in single-phase AC and/or DC systems for over- or undervoltage monitoring as well as detection of phase loss. The devices are available with different supply voltage ranges, provide an adjustable tripping delay and work according to the ope ...
electronic-components-easy-guide
electronic-components-easy-guide

... Remote operation of TV is based on Infrared transmission and reception. Infrared is a form invisible light with a wavelength of 950 nano meters. Human eye cannot sense this wavelength so that infrared rays cannot be detected visually. The remote handset is used to emit modulated infrared light using ...
Chapter 6: Single Phase Transformer
Chapter 6: Single Phase Transformer

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

MAX9159 Dual LVDS Line Receiver General Description Features
MAX9159 Dual LVDS Line Receiver General Description Features

Linear Type (Exclusively Used to Detect the Angle of Vehicle
Linear Type (Exclusively Used to Detect the Angle of Vehicle

... 1. When using an infrared reflow oven, solder may not always be applied as intended. Be sure to use a hot air reflow oven or a type that uses infrared rays in combination with hot air. 2. The temperatures given above are the maximum temperatures at the terminals of the sensor when employing a hot ai ...
Automation control units
Automation control units

Super Duty Instructions.pm
Super Duty Instructions.pm

Voltage Regulator Placement - WindMil
Voltage Regulator Placement - WindMil

... terminals, the real goal is to maintain good voltage for the customers •  Frequently, we have to locate our regulators away from the areas where we want to adjust and correct voltages •  If one can calculate the electrical distance (Z) between the regulator’s terminals and the load center we wish to ...
< 1 ... 759 760 761 762 763 764 765 766 767 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report