substation monitoring and control
... Nowadays there are various electronic equipment available for remote operation of grid control. However, the main disadvantage of these systems is that they can be operated only from short ranges and also less reliable. Thus, to overcome the above drawbacks, we are using one of the wireless communic ...
... Nowadays there are various electronic equipment available for remote operation of grid control. However, the main disadvantage of these systems is that they can be operated only from short ranges and also less reliable. Thus, to overcome the above drawbacks, we are using one of the wireless communic ...
MAX2673EVKIT.pdf
... Figure 1 is the schematic for the EV kit as shipped. The output matching components (L1, L2, C4, and C5) are optimized for an output frequency of 900MHz. Capacitor C1 is a DC-blocking capacitor for the LO input port. To reduce the possibility of noise pickup, resistor R2 and capacitor C9 form a lowp ...
... Figure 1 is the schematic for the EV kit as shipped. The output matching components (L1, L2, C4, and C5) are optimized for an output frequency of 900MHz. Capacitor C1 is a DC-blocking capacitor for the LO input port. To reduce the possibility of noise pickup, resistor R2 and capacitor C9 form a lowp ...
Instruction Manual
... higher current output (maximum 24A for this power supply). Figure 9 shows the parallel connection between two 6303D power supplies at parallel tracking. One unit is set at 30V/5A (MASTER setting is 30V/2.5A) while the other is at 20V/6A (MASTER setting is 20V/3A). Figure 10 shows the parallel connec ...
... higher current output (maximum 24A for this power supply). Figure 9 shows the parallel connection between two 6303D power supplies at parallel tracking. One unit is set at 30V/5A (MASTER setting is 30V/2.5A) while the other is at 20V/6A (MASTER setting is 20V/3A). Figure 10 shows the parallel connec ...
Sub-1.0 pF Quad ESD Array
... protected line exceeds the reference voltage (Vf or VCC + Vf). The diodes will force the transient current to bypass the sensitive circuit. Data lines are connected at pins 1, 3, 4 and 6. The negative reference is connected at pin 2. This pin must be connected directly to ground by using a ground pl ...
... protected line exceeds the reference voltage (Vf or VCC + Vf). The diodes will force the transient current to bypass the sensitive circuit. Data lines are connected at pins 1, 3, 4 and 6. The negative reference is connected at pin 2. This pin must be connected directly to ground by using a ground pl ...
ixrfd631 - IXYS Colorado
... • Low Quiescent Supply Current • Low Propagation Delay • High Capacitive Load Drive Capability • Wide Operating Voltage Range • Kelvin Ground ...
... • Low Quiescent Supply Current • Low Propagation Delay • High Capacitive Load Drive Capability • Wide Operating Voltage Range • Kelvin Ground ...
MJB 250-315-355
... All maintenance and inspection operations must be carried out only with the authorisation of the person responsible for safety, with the machine at a standstill, disconnected from the supply (including the auxiliary circuits such as the anticondensation heaters). As the electric machine is a product ...
... All maintenance and inspection operations must be carried out only with the authorisation of the person responsible for safety, with the machine at a standstill, disconnected from the supply (including the auxiliary circuits such as the anticondensation heaters). As the electric machine is a product ...
STC03DE170HP
... The STC03DE170HP is manufactured in a hybrid structure, using dedicated high voltage Bipolar and low voltage MOSFET technologies, aimed to providing the best performance in ESBT topology. The STC03DE170HP is designed for use in aux ...
... The STC03DE170HP is manufactured in a hybrid structure, using dedicated high voltage Bipolar and low voltage MOSFET technologies, aimed to providing the best performance in ESBT topology. The STC03DE170HP is designed for use in aux ...
Embedded Conference Exhibition
... • The XCL206 series is a synchronous step-down DC/DC converter which integrates an inductor and a control IC in one tiny package. A stable power supply with an output current of 600mA is configured using only two capacitors connected externally. • Operating voltage range is from 2.0V to 6.0V. Output ...
... • The XCL206 series is a synchronous step-down DC/DC converter which integrates an inductor and a control IC in one tiny package. A stable power supply with an output current of 600mA is configured using only two capacitors connected externally. • Operating voltage range is from 2.0V to 6.0V. Output ...
III. power factor correction
... predominant loads are resistive and inductive. Resistive loads are incandescent lighting and resistance heating. Inductive loads are AC Motors, induction furnaces, transformers and ballast-type lighting. Inductive loads require two kinds of power: (i) active (or) working power to perform the work (m ...
... predominant loads are resistive and inductive. Resistive loads are incandescent lighting and resistance heating. Inductive loads are AC Motors, induction furnaces, transformers and ballast-type lighting. Inductive loads require two kinds of power: (i) active (or) working power to perform the work (m ...
Delphi DNT04, Non-Isolated Point of Load
... Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in an industry standard footprint. With creative design technology and ...
... Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in an industry standard footprint. With creative design technology and ...
INA337, 338: High-Temperature, Precision
... Lead Temperature (soldering, 10s) ............................................... +300°C NOTES: (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional oper ...
... Lead Temperature (soldering, 10s) ............................................... +300°C NOTES: (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional oper ...
Dual General-Purpose Operational Amplifiers
... NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of t ...
... NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of t ...
RESET MAX1947 Low Input/Output Voltage Step-Up DC-DC Converter with
... Regulator Output. Bypass with 10µF ceramic capacitor to GND for full-load capability. For less than 50% of full load, a 4.7µF capacitor can be used. ...
... Regulator Output. Bypass with 10µF ceramic capacitor to GND for full-load capability. For less than 50% of full load, a 4.7µF capacitor can be used. ...
Charge and Discharge Inspection Equipment
... Charge-Discharge Inspection Pattern Registration 100 standard patterns are registered as the charge-discharge inspection patterns. In addition, there can be up to 20 steps per 1 pattern of chargedischarge conditions. Setting are for mode (charging / discharging / pause), voltage value, current value ...
... Charge-Discharge Inspection Pattern Registration 100 standard patterns are registered as the charge-discharge inspection patterns. In addition, there can be up to 20 steps per 1 pattern of chargedischarge conditions. Setting are for mode (charging / discharging / pause), voltage value, current value ...
Variable-frequency drive
A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.