• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FB32957961
FB32957961

... high, the feedback signal from DFFB is blocked and the counter operates in the same way as a divide-by2 divider. When “MC” is low, the counter operates in the divide-by-3 mode. An advantage of this implementation is that the feedback logic gates, enclosed by the dash-lined box in Fig 3, can be absor ...
AB09 Rectifier Circuit
AB09 Rectifier Circuit

... During the positive portion of input signal diode D1 conducts so there exists a short circuit equivalent across D1 and open circuit equivalent across D2 and the output voltage appears across load resistor RL. During the negative portion of input voltage the roles of the diodes are reversed but maint ...
Manual of RC Timer ESC 30A Brushless Motor
Manual of RC Timer ESC 30A Brushless Motor

... Usually, low timing value can be used for most motors. We recommend the Low timing value for 2 poles motor and Medium timing value for motors with more than 6 poles to get a high efficiency. For higher speed, High timing value can be chosen. ...
AND8146/D High Current LED − Capacitive Drop Drive
AND8146/D High Current LED − Capacitive Drop Drive

... condition called ‘brown out’ where the AC line voltage drops another ten percent to 96 Vac. A ‘brown out’ condition occurs when the electrical utility company lowers the value of AC voltage generated. This happens under extreme high demand conditions; the utility does this to keep the generating equ ...
Datasheet HIS Ax2 Fx Gx
Datasheet HIS Ax2 Fx Gx

ECN33550 FP (PDF format, 406kBytes)
ECN33550 FP (PDF format, 406kBytes)

... reliability is required (such as use in nuclear power control, aerospace and aviation, automobile, traffic equipment, life-support-related medical equipment, fuel control equipment and various kinds of safety equipment). Inclusion of products in such application shall be fully at the risk of custome ...
Precision Rotary Potentiometer
Precision Rotary Potentiometer

... status with regard to the analogue measuring technique as far as high-quality measurement tasks are concerned due to the favourable value for money. They are mainly used for ...
Aug 2002 Lower the Output Voltage Ripple of Positive-to
Aug 2002 Lower the Output Voltage Ripple of Positive-to

... noise bringing the total to about 24µV). This compares favorably with the nominal 16-bit LSB increment of 31µV, thus barely impacting the converter dynamic range. The common mode output voltage of the circuit in Figure 2 is fixed at 0.5V DC, though some loads may require a different level if DC-coup ...
LXMG1626-12-45TrainingKit_rev1.1
LXMG1626-12-45TrainingKit_rev1.1

BSP75N - Infineon Technologies
BSP75N - Infineon Technologies

... logic level input, an open drain DMOS output stage and integrated protection functions. It is designed for all kind of resistive and inductive loads (relays, solenoid) in automotive and industrial applications. Protection Functions • Over voltage protection: An internal clamp limits the output volta ...
Electrical excitation of the local earth for resonant, wireless energy
Electrical excitation of the local earth for resonant, wireless energy

... created a steep ravine. A surface electrode was placed on the top of the ravine, level with the surrounding land. A second electrode was placed at the bottom of the ravine (approximately 40 m below the top). Two helical, quarter standing-wave resonators were constructed and used as the receivers in ...
PDF
PDF

... the measurement accuracy of the WS-V Series MDU breakers, as shown in Table 1. In addition, the display is compact, and the WS-V Series MDU breaker has the LCD display on the name plate in the same way as an electronic-hybrid type breaker with the current indication function (panel mounting type wit ...
An equivalent circuit formulation for three-phase power
An equivalent circuit formulation for three-phase power

... ability to incorporate any electrical load (e.g. converters, solar cells, high voltage DC components, etc.) effortlessly into its formulation. Furthermore, the proposed approach in this paper allows for use of unified modeling methodology to perform various power system simulations such as steadysta ...
How Much DC Power Is Necessary?
How Much DC Power Is Necessary?

... The general power system architecture suggested by the notional fragment in Fig. 1 is potentially reasonable if propulsion power is provided by a variable speed electric drive, and if the entire electric propulsion power must be provided by a DC bus energizing the variable speed, DC-AC inverter for ...
Rapid Wireless Capacitor Charging Using a Multi
Rapid Wireless Capacitor Charging Using a Multi

... diminishing returns due to the fixed source impedance, eventually plateauing beyond coupling coefficients greater than 0.2. In other words, at high values of , the reflection coefficient becomes large, requiring a large (due to the inverse relationship) to create an impedance that matches ...
RMS Voltage For a driving voltage of the form or a current of the form
RMS Voltage For a driving voltage of the form or a current of the form

User Manual
User Manual

... 1. The wire connection can only be done after the inverter is fixed in proper position on the wall. 2. Make sure the Max. open circuit voltage and short circuit current of solar arrays are not exceeded the stipulated range of the inverter. 3. Select the inner diameter of 12AWG (4mm 2) and the outer ...
FEATURES GENERAL DESCRIPTION The ADP194CB-EVALZ is used to demonstrate the function-
FEATURES GENERAL DESCRIPTION The ADP194CB-EVALZ is used to demonstrate the function-

... ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken ...
Voltage source
Voltage source

... Most sources of electrical energy (the mains, a battery, ...) are best modelled as voltage sources. An ideal voltage source provides no energy when it is loaded by an open circuit (i.e. an infinite impedance), but approaches infinite energy and current when the load resistance approaches zero (a sho ...
ACT20M Presentation - Weidmuller B2B Portal
ACT20M Presentation - Weidmuller B2B Portal

Aalborg Universitet Islanded Microgrids
Aalborg Universitet Islanded Microgrids

Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB- 1a4
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB- 1a4

... a) the voltage level at the point of connection between the transmission system and a generating unit or an aggregated generating facility, including those in a power plant or an industrial complex; or (b) the reactive power to be achieved by the generating unit, aggregated generating facility, powe ...
Sensorless Control for a Switched Reluctance Wind Generator
Sensorless Control for a Switched Reluctance Wind Generator

A current-saving match-line sensing scheme for
A current-saving match-line sensing scheme for

... 0.13µm CMOS process. Figure 17.3.1 shows a general CAM architecture where searchlines (SL) run perpendicular to MLs. The search data is presented to the SLs which are connected bit-by-bit to all the words stored in the memory. A NAND-based ML architecture is well known [4] for its low power consumpt ...
AYA DAC - Audiostereo.pl
AYA DAC - Audiostereo.pl

... production and tolerances are not small, to choose the right value for this resistor we would have to know the Idss of the used sample. Manufacturers are sometimes helpful making ranges of the certain pieces with regard to the Idss (so we have BF245A, -B and – C, and we have 2SK170GR, -BL and –Y). I ...
< 1 ... 505 506 507 508 509 510 511 512 513 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report