• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

... EE415 VLSI Design ...
Design control and protection for medium voltage switchgear  Carl-Johan Nylund
Design control and protection for medium voltage switchgear Carl-Johan Nylund

... distribution. ZS1 has replaced 18 previous products. Because of a rich variety on the switchgear market, ABB introduced the ZS1 to meet the specifications of each country market. ZS1 was used because it is what you will find out on the market today. Ten cabinets were needed from the ZS1 series for t ...
A Designer`s Guide to Instrumentation Amplifiers
A Designer`s Guide to Instrumentation Amplifiers

Powermonitor 3000 Master Module Installation Instructions
Powermonitor 3000 Master Module Installation Instructions

... Although the power monitor ships from the factory with default settings, you need to configure it for your particular requirements. You may configure the power monitor by using the optional display module. Alternately, you may use an external device or application to write configuration, operational ...
An MSP430F11x1 Sigma-Delta Type Millivolt
An MSP430F11x1 Sigma-Delta Type Millivolt

... resources. Please see the reference section at the end of this report for the UART application report reference number. ...
GA-H61M-DS2
GA-H61M-DS2

... the local voltage standard. •• Before using the product, please verify that all cables and power connectors of your hardware components are connected. •• To prevent damage to the motherboard, do not allow screws to come in contact with the motherboard circuit or its components. •• Make sure there ar ...
First Principles of a Gas Discharge Tube (GDT) Primary
First Principles of a Gas Discharge Tube (GDT) Primary

... 1752. However, it was in 1859 that Yale University described the use of the first spark gap protection solution. The document uses Franklin’s experiment to harness the energy of a lightning storm. The kite was tied to an insulated post where the metallic string going to the kite was connected to a b ...
Classic Connectors - ArresterWorks.com
Classic Connectors - ArresterWorks.com

... just the first of many that Creighton filed over the next eighteen years. GE had won the patent campaign, but that was all Figure 4 1910 Westinghouse Electric Instruction Manual they won. Over the next twenty years, GE on Type A Electrolytic Arrester and Westinghouse both marketed and sold electroly ...
An MSP430F11x1 Sigma-Delta Type Millivolt Meter
An MSP430F11x1 Sigma-Delta Type Millivolt Meter

... resources. Please see the reference section at the end of this report for the UART application report reference number. ...
Application Note DrBlade™ 2 Selection of Boot Capacitor Value
Application Note DrBlade™ 2 Selection of Boot Capacitor Value

Optimal Single Resistor Damping of Input Filters
Optimal Single Resistor Damping of Input Filters

... The need for damping in the L-C input filters of switching converters is well appreciated within the power electronics field [1-7]. Adequate filter damping may be necessary to avoid destabilizing the feedback loops of dc-dc converters with duty cycle control [1,2] or currentprogrammed control [4,5]. ...
Comparative Study of Fluid Coupling for Oil and water as
Comparative Study of Fluid Coupling for Oil and water as

Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renes ...
Considerations for Using High-Impedance or Low
Considerations for Using High-Impedance or Low

... differential relay does not need to provide magnitude or phase angle compensation because of transformer winding ratios and connections. Likewise, bus differential schemes do not have to contend with magnetizing inrush currents that require transformer bus differential relay schemes to employ harmon ...
6RA70 Series Base Drive Instruction Manual
6RA70 Series Base Drive Instruction Manual

... serial interface on the basic unit. This PC interface is used during start-up, for maintenance during shutdown and for diagnosis in operation. Furthermore, converter software upgrades can be loaded through this interface for storage in flash memory. On single-quadrant converters, a fully controlled ...
OPERATOR’S MANUAL BHK-MG FULL RACK SERIES POWER SUPPLY MODELS
OPERATOR’S MANUAL BHK-MG FULL RACK SERIES POWER SUPPLY MODELS

FailSafe: A Generalized Methodology for Converter
FailSafe: A Generalized Methodology for Converter

Analysis of fully differential amplifiers
Analysis of fully differential amplifiers

ZL70102 Medical Implantable RF Transceiver (Datasheet, Full
ZL70102 Medical Implantable RF Transceiver (Datasheet, Full

... 400-MHz RF transmitter output to matching network ...
Design of Ultra-Low-Power Analog-to-Digital Converters Dai Zhang
Design of Ultra-Low-Power Analog-to-Digital Converters Dai Zhang

... Medical implant devices, such as pacemakers and cardiac defibrillators, typically require low-speed, medium-resolution ADCs. The successive approximation register (SAR) ADC exhibits significantly high energy efficiency compared to other prevalent ADC architectures due to its good tradeoffs among pow ...
MEC 20 - Baldor.com
MEC 20 - Baldor.com

... Non-volatile memory retains logic and set points if control power is lost. ...
NTS0104 1. General description Dual supply translating transceiver; open drain; auto
NTS0104 1. General description Dual supply translating transceiver; open drain; auto

... The NTS0104 is a 4-bit, dual supply translating transceiver with auto direction sensing, that enables bidirectional voltage level translation. It features two 4-bit input-output ports (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any vol ...
PowerLogic™ PM5100 Series Power and
PowerLogic™ PM5100 Series Power and

Aluminum Electrolytic Capacitors
Aluminum Electrolytic Capacitors

in Word Doc Format
in Word Doc Format

... (c) Remains constant with the load current (d) Has the lowest value (Ans) 35. In different parts of the country identical telephone numbers are distinguished by their (a) Language digits (b) Access digits (c) Area codes (Ans) (d) Central office codes 36. Amplitude modulation is used for broadcasting ...
< 1 ... 35 36 37 38 39 40 41 42 43 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report