
SLP 05 - Cary Audio
... WATER AND MOISTURE: Do not use the unit near water (for example, near a swimming pool, bath tub, wash bowl, kitchen sink, or laundry tub) or in a damp environment (like a basement or outside in the rain). OBJECT AND LIQUID ENTRY: Do not push objects of any kind into the unit through openings as they ...
... WATER AND MOISTURE: Do not use the unit near water (for example, near a swimming pool, bath tub, wash bowl, kitchen sink, or laundry tub) or in a damp environment (like a basement or outside in the rain). OBJECT AND LIQUID ENTRY: Do not push objects of any kind into the unit through openings as they ...
Sunwood Motorised Brochure
... The following power supply options provide an overview of the different options available within the Sunwood motorised blind range: ...
... The following power supply options provide an overview of the different options available within the Sunwood motorised blind range: ...
STM6710
... If a monitored supply voltage input falls below the minimum voltage threshold, a single active low output is asserted, triggering a system reset. This device can be configured to support an external manual reset input using minimal external components. Monitoring up to four different voltages in a s ...
... If a monitored supply voltage input falls below the minimum voltage threshold, a single active low output is asserted, triggering a system reset. This device can be configured to support an external manual reset input using minimal external components. Monitoring up to four different voltages in a s ...
4. SIGNAL PROCESSING CIRCUITRY 4.1. INTRODUCTION
... The successful extraction of the information superimposed on the Hall voltage requires for the correct analog signal processing circuits to be developed. The objective of analog circuit design is to transform the specifications into hardware capable of attaining these specifications. As integrated c ...
... The successful extraction of the information superimposed on the Hall voltage requires for the correct analog signal processing circuits to be developed. The objective of analog circuit design is to transform the specifications into hardware capable of attaining these specifications. As integrated c ...
Low Ambient Temperature Head Pressure Control
... NOTE: The VFD is phase insensitive in regard to incoming line voltage, which means that the VFD will operate with any phase sequence of the incoming three-phase power. The standard outdoor air temperature limitation of 30RB and 30XA chillers is 32 F (0° C). The low ambient temperature controller ope ...
... NOTE: The VFD is phase insensitive in regard to incoming line voltage, which means that the VFD will operate with any phase sequence of the incoming three-phase power. The standard outdoor air temperature limitation of 30RB and 30XA chillers is 32 F (0° C). The low ambient temperature controller ope ...
SEL Arc-Flash Solutions
... application of current-limiting fuses. However, the best and most direct way to reduce arc-flash hazards is to reduce fault-clearing times, thereby reducing the overall incident energy, or to eliminate the need for personnel to be in harm’s way by using remote operation. ...
... application of current-limiting fuses. However, the best and most direct way to reduce arc-flash hazards is to reduce fault-clearing times, thereby reducing the overall incident energy, or to eliminate the need for personnel to be in harm’s way by using remote operation. ...
DTC C1221-C1235
... wash, etc.), inspect the wheel speed sensor wiring for signs of water intrusion. If the DTC is not current, clear all DTCs and simulate the effects of water intrusion by using the following procedure: 1. Spray the suspected area with a 5 percent saltwater solution. To create a 5 percent saltwater so ...
... wash, etc.), inspect the wheel speed sensor wiring for signs of water intrusion. If the DTC is not current, clear all DTCs and simulate the effects of water intrusion by using the following procedure: 1. Spray the suspected area with a 5 percent saltwater solution. To create a 5 percent saltwater so ...
PDF: 1.47MB
... became possible to decrease the thermal resistance between junction and case Rth(j-c) substantially. And also it incorporates Mitsubishi's latest power chips CSTBT. So that despite its mounting area decreases to 75%, it realized higher current rating up to 50A. (2) Changing the method of short circu ...
... became possible to decrease the thermal resistance between junction and case Rth(j-c) substantially. And also it incorporates Mitsubishi's latest power chips CSTBT. So that despite its mounting area decreases to 75%, it realized higher current rating up to 50A. (2) Changing the method of short circu ...
AN1322 Applying Semiconductor Sensors to Bar Graph
... approach is that it is very flexible regarding the number of segments that are used, and has the availability through software to independently adjust scaling factors for each segment. This approach is particularly useful for process monitoring in systems where a microprocessor is already in place. ...
... approach is that it is very flexible regarding the number of segments that are used, and has the availability through software to independently adjust scaling factors for each segment. This approach is particularly useful for process monitoring in systems where a microprocessor is already in place. ...
MAX15041 Evaluation Kit Evaluates: General Description Features
... MAX15041 Evaluation Kit The MAX15041 evaluation kit (EV kit) is a fully assembled and tested circuit board that evaluates the MAX15041 synchronous buck converter IC with integrated high-side and low-side switches. The EV kit output is configured to 3.3V and delivers up to 3A output current. The EV k ...
... MAX15041 Evaluation Kit The MAX15041 evaluation kit (EV kit) is a fully assembled and tested circuit board that evaluates the MAX15041 synchronous buck converter IC with integrated high-side and low-side switches. The EV kit output is configured to 3.3V and delivers up to 3A output current. The EV k ...
industrial accelerometers
... tolerance, the calibrated output of the sensor could range from 90 mV/g (-10%) to 110 mV/g (+10%). However, if you were to choose a 500 mV/g accelerometer with a +/- 10% sensitivity tolerance, the calibrated output of the sensor could range from 450 mV/g (-10%) to 550 mV/g (+10%). Since vibration an ...
... tolerance, the calibrated output of the sensor could range from 90 mV/g (-10%) to 110 mV/g (+10%). However, if you were to choose a 500 mV/g accelerometer with a +/- 10% sensitivity tolerance, the calibrated output of the sensor could range from 450 mV/g (-10%) to 550 mV/g (+10%). Since vibration an ...
MAX9150 Low-Jitter, 10-Port LVDS Repeater Ordering Information Typical Application Circuit
... data rates with reduced power consumption while reducing EMI emissions and system susceptibility to noise. The MAX9150 is a 400Mbps, 10-port LVDS repeater intended for high-speed, point-to-point, low-power applications. This device accepts an LVDS input and repeats it on 10 LVDS outputs. The device ...
... data rates with reduced power consumption while reducing EMI emissions and system susceptibility to noise. The MAX9150 is a 400Mbps, 10-port LVDS repeater intended for high-speed, point-to-point, low-power applications. This device accepts an LVDS input and repeats it on 10 LVDS outputs. The device ...
DUAL OUTPUT POWER SUPPLY Agilent MODEL
... Less than 0.1% plus 5 mV (dc to 20 Hz) during 8 hours at constant line, load and ambient after an initial warm-up time of 30 minutes. ...
... Less than 0.1% plus 5 mV (dc to 20 Hz) during 8 hours at constant line, load and ambient after an initial warm-up time of 30 minutes. ...
Aalborg Universitet Kocewiak, Lukasz; Hjerrild, Jesper ; Bak, Claus Leth
... seen from the connection point of Karnice (Skrobotowo) Wind Farm performed by Institute of Power Engineering, Gdansk [17]. The aim of the impedance calculations has been to identify resonance points at the 110 kV power busbar of Skrobotowo substation. Calculations have been carried out for different ...
... seen from the connection point of Karnice (Skrobotowo) Wind Farm performed by Institute of Power Engineering, Gdansk [17]. The aim of the impedance calculations has been to identify resonance points at the 110 kV power busbar of Skrobotowo substation. Calculations have been carried out for different ...
Smart Power Switch - Texas Instruments
... packages and can accommodate both low side (load to VCC) or high side (load to GND) configurations. The UC37131 and UC37133 are exclusively for a low side or a high side configuration respectively and both are available in an 8 pin package. Both high side and low side configurations provide high cur ...
... packages and can accommodate both low side (load to VCC) or high side (load to GND) configurations. The UC37131 and UC37133 are exclusively for a low side or a high side configuration respectively and both are available in an 8 pin package. Both high side and low side configurations provide high cur ...
Fundamentals of Floating Measurements and Isolated
... can be easily done with almost any oscilloscope and its standard probes. Keep in mind that both test points must be referenced to ground. Thus ...
... can be easily done with almost any oscilloscope and its standard probes. Keep in mind that both test points must be referenced to ground. Thus ...
BD5291G
... Then input pin voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input current can be set to less than the rated current by adding a limiting resistor. Caution: Operating the IC over the abs ...
... Then input pin voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input current can be set to less than the rated current by adding a limiting resistor. Caution: Operating the IC over the abs ...
RM17TG00 Datasheet - Mouser Electronics
... Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end ...
... Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.