
I56-3889-002R - Silent Knight
... for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above ...
... for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above ...
MAX2630–MAX2633 VHF-to-Microwave, +3V, General-Purpose Amplifiers _______________General Description
... The VCC pin must be RF bypassed for correct operation. To accomplish this, connect a capacitor between the VCC pin and ground, as close to the package as is practical. Use the same equation given above (for DCblocking capacitor values) to calculate the minimum capacitor value. If the PC board has lo ...
... The VCC pin must be RF bypassed for correct operation. To accomplish this, connect a capacitor between the VCC pin and ground, as close to the package as is practical. Use the same equation given above (for DCblocking capacitor values) to calculate the minimum capacitor value. If the PC board has lo ...
Power Supply Measurement and Analysis
... the operating input voltage and the topology of the switchmode converters. A typical DC power supply designed for computing equipment operates on universal utility voltage ranging from 80 Vrms to 264 Vrms. At maximum input voltage, the OFF state voltage across the switching device (between TP1 and T ...
... the operating input voltage and the topology of the switchmode converters. A typical DC power supply designed for computing equipment operates on universal utility voltage ranging from 80 Vrms to 264 Vrms. At maximum input voltage, the OFF state voltage across the switching device (between TP1 and T ...
ACOK MAX1508/MAX1508Y/MAX1508Z Linear Li+ Battery Charger with Integrated Pass FET, Thermal Regulation, and
... cell with 10% of the user-programmed fast-charge current. There is no prequalification stage for the MAX1508Z and MAX1508Y in order to allow startup into a load without a battery. The CHG indicator output is driven low (Figure 2) to indicate entry into the prequalification state. Once the cell has p ...
... cell with 10% of the user-programmed fast-charge current. There is no prequalification stage for the MAX1508Z and MAX1508Y in order to allow startup into a load without a battery. The CHG indicator output is driven low (Figure 2) to indicate entry into the prequalification state. Once the cell has p ...
AND gate
... • NAND gate: produces the opposite of an AND gate’s output, a 0 if and only if all of its inputs are 1. • NOR gate: produces the opposite of an OR gate’s output, a 0 if and only if one or more of its inputs are 1. • The symbols and truth tables for NAND and NOR may be extended to gates with any numb ...
... • NAND gate: produces the opposite of an AND gate’s output, a 0 if and only if all of its inputs are 1. • NOR gate: produces the opposite of an OR gate’s output, a 0 if and only if one or more of its inputs are 1. • The symbols and truth tables for NAND and NOR may be extended to gates with any numb ...
BU7250G
... Then input pin voltage is set to more than VSS. (Note 5) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input current can be set to less than the rated current by adding a limiting resistor. Caution: Operating the IC over the abs ...
... Then input pin voltage is set to more than VSS. (Note 5) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input current can be set to less than the rated current by adding a limiting resistor. Caution: Operating the IC over the abs ...
AAT2605 数据资料DataSheet下载
... For proper load voltage regulation and operational stability, a capacitor is required between pins VOUT and GND. The COUT capacitor connection to the LDO regulator ground pin should be made as direct as practically possible for maximum device performance. The AAT2605's LDO regulators have been speci ...
... For proper load voltage regulation and operational stability, a capacitor is required between pins VOUT and GND. The COUT capacitor connection to the LDO regulator ground pin should be made as direct as practically possible for maximum device performance. The AAT2605's LDO regulators have been speci ...
HF2614291439
... Power systems are subjected to low frequency disturbances that might cause loss of synchronism and an eventual breakdown of entire system. The oscillations, which are typically in the frequency range of 0.2 to 3.0 Hz, might be excited by the disturbances in the system or, in some cases, might even b ...
... Power systems are subjected to low frequency disturbances that might cause loss of synchronism and an eventual breakdown of entire system. The oscillations, which are typically in the frequency range of 0.2 to 3.0 Hz, might be excited by the disturbances in the system or, in some cases, might even b ...
OIP A 67 dBm Multistacked Junction Varactor 3
... ECENTLY, radio frequency (RF) adaptive systems have drawn a lot of attention, resulting in an intensive search for low-cost low-distortion tunable elements. Potential candidates are semiconductor diodes [1]–[4], MEMS switches/varactors [5], [6] and Barium Strontium Titanate (BST) varactors [7]. Alth ...
... ECENTLY, radio frequency (RF) adaptive systems have drawn a lot of attention, resulting in an intensive search for low-cost low-distortion tunable elements. Potential candidates are semiconductor diodes [1]–[4], MEMS switches/varactors [5], [6] and Barium Strontium Titanate (BST) varactors [7]. Alth ...
Implementation of Artificial Intelligence Technique to Model Arc
... an arc furnace. Considering the non-linear relationship between the arc voltage and the arc current and lack of knowledge associated with the process dynamics, artificial intelligence (AI) techniques can be applied to extract nonlinear relationships between the input and the output pattern of arc fu ...
... an arc furnace. Considering the non-linear relationship between the arc voltage and the arc current and lack of knowledge associated with the process dynamics, artificial intelligence (AI) techniques can be applied to extract nonlinear relationships between the input and the output pattern of arc fu ...
Lab: Series and Parallel Circuits
... Procedure for Part A: Simple Circuit 1. Before building your circuit, measure the voltage across the battery. To do this, connect the negative terminal of the battery to the black negative terminal of the voltmeter. Connect the positive terminal of the battery to the red positive terminal of the vol ...
... Procedure for Part A: Simple Circuit 1. Before building your circuit, measure the voltage across the battery. To do this, connect the negative terminal of the battery to the black negative terminal of the voltmeter. Connect the positive terminal of the battery to the red positive terminal of the vol ...
ABB industrial drives ACS880, multidrives 1.5 to 5600 kW Catalog
... diode supply module has thyristor charging, BCU control unit and 6-pulse and 12-pulse versions available. IGBT supply unit (ISU) An IGBT supply unit is used in regenerative drive systems to convert three-phase AC voltage to DC voltage. ISU is made of nxR8i inverter frames and LCL line filters for a ...
... diode supply module has thyristor charging, BCU control unit and 6-pulse and 12-pulse versions available. IGBT supply unit (ISU) An IGBT supply unit is used in regenerative drive systems to convert three-phase AC voltage to DC voltage. ISU is made of nxR8i inverter frames and LCL line filters for a ...
2208e 2204e Programmer/Controllers Product data MODELS
... the option of two control outputs, two alarm relays and a communications module. Two Digital inputs are included as standard. The hardware is configurable for heating, cooling or alarms. The 2204e/2208e is fully configurable on-site. Precise control An advanced PID control algorithm gives stable ‘St ...
... the option of two control outputs, two alarm relays and a communications module. Two Digital inputs are included as standard. The hardware is configurable for heating, cooling or alarms. The 2204e/2208e is fully configurable on-site. Precise control An advanced PID control algorithm gives stable ‘St ...
LT1033 - 3A Negative Adjustable Regulator
... it is possible to damage the regulator if the input voltage becomes shorted, due to the output capacitor discharging into the regulator. This can be prevented by using diode D1 (see Figure 2) between the input and the output. The input capacitor, C2, is only required if the regulator is more than 4 ...
... it is possible to damage the regulator if the input voltage becomes shorted, due to the output capacitor discharging into the regulator. This can be prevented by using diode D1 (see Figure 2) between the input and the output. The input capacitor, C2, is only required if the regulator is more than 4 ...
Extending the MFJ-927 to 160-Meters
... discussed in that review only the SG-230 had enough internal inductance to tune the 43foot vertical on 160 meters, so I described an external inductor (in the “Articles” section of this website) that could be strapped in to permit the MFJ-927 to tune a 43-footer on top band. I’ve also recently added ...
... discussed in that review only the SG-230 had enough internal inductance to tune the 43foot vertical on 160 meters, so I described an external inductor (in the “Articles” section of this website) that could be strapped in to permit the MFJ-927 to tune a 43-footer on top band. I’ve also recently added ...
2SC3838K
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
UXM15P-Datasheet 2008-2-28 ROHS:UXM15P-Datasheet 2005
... DC resistance of the receiving circuits should be ~50 ohms (or less) to VCC to prevent excessive common mode voltage from saturating the prescaler outputs. If AC coupling is used, the perfect embodiment is shown in figure 2. The discrete R/L/C elements should be resonance free up to the maximum freq ...
... DC resistance of the receiving circuits should be ~50 ohms (or less) to VCC to prevent excessive common mode voltage from saturating the prescaler outputs. If AC coupling is used, the perfect embodiment is shown in figure 2. The discrete R/L/C elements should be resonance free up to the maximum freq ...
Effectively Using Pressure, Load, and Torque Sensors with Today`s
... Utilizing high quality pressure, load, and torque sensors, and selecting the correct design and installation for the application are critical to ensuring data integrity for the measurement system. To be successful, the following information must be understood: • The basic operating parameters of pr ...
... Utilizing high quality pressure, load, and torque sensors, and selecting the correct design and installation for the application are critical to ensuring data integrity for the measurement system. To be successful, the following information must be understood: • The basic operating parameters of pr ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.