MAX17126B Multi-Output Power Supplies with VCOM Amplifier EVALUATION KIT AVAILABLE
... The step-up and step-down switching regulators feature internal power MOSFETs and high-frequency operation allowing the use of small inductors and capacitors, resulting in a compact solution. The step-up regulator provides TFT source driver supply voltage, while the step-down regulator provides the ...
... The step-up and step-down switching regulators feature internal power MOSFETs and high-frequency operation allowing the use of small inductors and capacitors, resulting in a compact solution. The step-up regulator provides TFT source driver supply voltage, while the step-down regulator provides the ...
experimental procedure
... Oscillators can product signals in different forms. The frequency and amplitude of these signals could have been regulated. Oscillators not only used to produce signal but also used for different purposes (mixer, amplifier and a modulator etc.). Normally oscillators are amplifiers. Their operating p ...
... Oscillators can product signals in different forms. The frequency and amplitude of these signals could have been regulated. Oscillators not only used to produce signal but also used for different purposes (mixer, amplifier and a modulator etc.). Normally oscillators are amplifiers. Their operating p ...
bq769x0 boot switch alternatives
... Booting From an External Signal When the simplified system, as shown in the bq769x0 data sheet, is shut down, the FETs are off and the PACK terminals are expected to show 0 V. In most systems, the power FETs will have some small leakage current. Additionally, the CHG pin provides some pulldown throu ...
... Booting From an External Signal When the simplified system, as shown in the bq769x0 data sheet, is shut down, the FETs are off and the PACK terminals are expected to show 0 V. In most systems, the power FETs will have some small leakage current. Additionally, the CHG pin provides some pulldown throu ...
Hammond Manufacturing Line Transformers
... Straight Isolation - Constant Voltage - Plug In (CV Series) ...
... Straight Isolation - Constant Voltage - Plug In (CV Series) ...
2SK3796 N-Channel JFET 30V, 0.6 to 3.0mA
... ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www ...
... ON Semiconductor and the ON logo are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www ...
Capturing Generator Rotor Angle and Field Quantities
... The current signal has a similar characteristic, though it is measured through slightly different means. Where the voltage signal can, with proper isolation, be safely connected to the measurement device, the current flowing through the field winding can be several hundreds to thousands of amperes, ...
... The current signal has a similar characteristic, though it is measured through slightly different means. Where the voltage signal can, with proper isolation, be safely connected to the measurement device, the current flowing through the field winding can be several hundreds to thousands of amperes, ...
MAX847 1-Cell, Step-Up Two-Way Pager System IC ________________General Description
... Chip Select for SPI Serial Interface Run/Coast. Permits toggling between Run and Coast Modes via logic signal. Run is selected when either RUN or the internal RUN/COAST bit is high. Coast is selected when both are low. ...
... Chip Select for SPI Serial Interface Run/Coast. Permits toggling between Run and Coast Modes via logic signal. Run is selected when either RUN or the internal RUN/COAST bit is high. Coast is selected when both are low. ...
2. Communicating Fault Passage indicators
... The network view window includes vertical and horizontal scrolling functions so that it can be bigger than the screen size. The network is drawn using animated symbols to represent each substation and lines (non-animated) for electrical lines and cables as well as other graphical objects. Each subst ...
... The network view window includes vertical and horizontal scrolling functions so that it can be bigger than the screen size. The network is drawn using animated symbols to represent each substation and lines (non-animated) for electrical lines and cables as well as other graphical objects. Each subst ...
PDF: 1.54MB
... transfer mold package favorable for larger mass production. Power chips, drive and protection circuits are integrated in the module, which make it easy for AC100-240V class low power motor inverter control. DIP Ver.6 takes over the functions of conventional DIP Ver.5 (such as incorporating bootstrap ...
... transfer mold package favorable for larger mass production. Power chips, drive and protection circuits are integrated in the module, which make it easy for AC100-240V class low power motor inverter control. DIP Ver.6 takes over the functions of conventional DIP Ver.5 (such as incorporating bootstrap ...
S225-40-7
... The RS-485 communications board allows digital SCADA communication from the CL-5/CL-6 series regulator control to external remote communication devices. Several Function Codes (FC) must be set properly when attempting to use the second communications port: for CL-5 series, FC 64—FC 68; for CL-6 seri ...
... The RS-485 communications board allows digital SCADA communication from the CL-5/CL-6 series regulator control to external remote communication devices. Several Function Codes (FC) must be set properly when attempting to use the second communications port: for CL-5 series, FC 64—FC 68; for CL-6 seri ...
Title Experiment using variable reactor of rectifier type
... of one cycle. In the graph (lower trace), the current of the trigger has decayed quickly after S/N transition occurred and coil starts limiting. The inductor current then the line current follows the throughout the fault time. When fault is cleared, returns to the normal value. However, the does not ...
... of one cycle. In the graph (lower trace), the current of the trigger has decayed quickly after S/N transition occurred and coil starts limiting. The inductor current then the line current follows the throughout the fault time. When fault is cleared, returns to the normal value. However, the does not ...
PS9331L, PS9331L2 Data Sheet Preliminary
... Avoid removing the residual flux with freon-based and chlorine-based cleaning solvent. ...
... Avoid removing the residual flux with freon-based and chlorine-based cleaning solvent. ...
Rev D - AMETEK Programmable Power
... The MX Series AC and DC power source systems are high efficiency, floor standing AC and DC power sources that provide a precise output with low distortion. Available voltage ranges are 150 Vac, 300 Vac and 400 Vac in AC mode and 200 Vdc and 400 Vdc in DC mode. The MX45-3Pi can operate in either sing ...
... The MX Series AC and DC power source systems are high efficiency, floor standing AC and DC power sources that provide a precise output with low distortion. Available voltage ranges are 150 Vac, 300 Vac and 400 Vac in AC mode and 200 Vdc and 400 Vdc in DC mode. The MX45-3Pi can operate in either sing ...
- Spiral - Imperial College London
... ES is considered to be in voltage support (i.e. capacitive) mode as indicated by the negative sign of QES. For a purely resistive non-critical load, QES and QSL are equal and are shown by the black trace in Fig. 6(b). QES and QSL for an R-L non-critical load with 0.95 power factor are shown by blue ...
... ES is considered to be in voltage support (i.e. capacitive) mode as indicated by the negative sign of QES. For a purely resistive non-critical load, QES and QSL are equal and are shown by the black trace in Fig. 6(b). QES and QSL for an R-L non-critical load with 0.95 power factor are shown by blue ...
LT1942
... Built-In LED Dimming Capability Open LED Protection for LED Driver 24-Lead QFN Package (4mm × 4mm) ...
... Built-In LED Dimming Capability Open LED Protection for LED Driver 24-Lead QFN Package (4mm × 4mm) ...
- ibookfi.com
... RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There ...
... RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There ...
Keysight Technologies B1505A Power Device Analyzer/Curve Tracer
... suffer more from the effects of residual and stray capacitance and inductance than do traditional low-power semiconductor device measurements due to the high currents and voltages that power devices require. The only way to ensure measurement integrity is to visually verify the applied waveforms, wh ...
... suffer more from the effects of residual and stray capacitance and inductance than do traditional low-power semiconductor device measurements due to the high currents and voltages that power devices require. The only way to ensure measurement integrity is to visually verify the applied waveforms, wh ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.