
module 1
... consumers get power supply at 400-440 V. Note that the above figures are given for line-to-line voltages. Since domestic customers get single-phase supplies, they usually receive 230-250 V at their inlet points. While a domestic customer with a low power consumption gets a single-phase supply, both ...
... consumers get power supply at 400-440 V. Note that the above figures are given for line-to-line voltages. Since domestic customers get single-phase supplies, they usually receive 230-250 V at their inlet points. While a domestic customer with a low power consumption gets a single-phase supply, both ...
MAX5839 Octal, 13-Bit Voltage-Output DAC with Parallel Interface General Description
... output amplifier. The DUTGND pins are typically connected directly to analog ground. Each of these pins has an input current that varies with the DAC digital code. If the DUTGND pins are driven by external circuitry, budget ±200µA per DAC for load current. ...
... output amplifier. The DUTGND pins are typically connected directly to analog ground. Each of these pins has an input current that varies with the DAC digital code. If the DUTGND pins are driven by external circuitry, budget ±200µA per DAC for load current. ...
Old Company Name in Catalogs and Other Documents
... 2. The input voltage should be allowed to input without damage or destruction independent of the magnitude of V+. Either input signal should not be allowed to go negative by more than 0.3 V. The normal operation will establish when any input is within the Common Mode Input Voltage Range of electrica ...
... 2. The input voltage should be allowed to input without damage or destruction independent of the magnitude of V+. Either input signal should not be allowed to go negative by more than 0.3 V. The normal operation will establish when any input is within the Common Mode Input Voltage Range of electrica ...
Russian Regulators: Part VI for the Nippon-Denso 770
... “Fault” Light is Optional on N-D Alternator (note: light was mandatory for initial rotor current in previous 14.3771 35-Amp alternator (Russian hand grenade)) ...
... “Fault” Light is Optional on N-D Alternator (note: light was mandatory for initial rotor current in previous 14.3771 35-Amp alternator (Russian hand grenade)) ...
SP4082E 数据资料DataSheet下载
... The SP4082E is designed for reliable, bidirectional communication on multipoint bus transmission lines. The device contains one differential driver and one differential receiver. It is a half-duplex device. The device complys with TIA/EIA-485 and TIA/EIA-422 standards. Lead-free and RoHS compliant p ...
... The SP4082E is designed for reliable, bidirectional communication on multipoint bus transmission lines. The device contains one differential driver and one differential receiver. It is a half-duplex device. The device complys with TIA/EIA-485 and TIA/EIA-422 standards. Lead-free and RoHS compliant p ...
SP3490 数据资料DataSheet下载
... output swing with no load will be 0 volts to Vcc. With worst case loading of 54Ω across the differential outputs, the drivers can maintain greater than 1.5V voltage levels. The driver of the SP3491 has a driver enable control line which is active HIGH. A logic HIGH on DE (pin 4) of the SP3491 will e ...
... output swing with no load will be 0 volts to Vcc. With worst case loading of 54Ω across the differential outputs, the drivers can maintain greater than 1.5V voltage levels. The driver of the SP3491 has a driver enable control line which is active HIGH. A logic HIGH on DE (pin 4) of the SP3491 will e ...
FDMS3686S PowerTrench Power Stage
... between the thermal and electrical performance of Power Stage. 3. Output inductor location should be as close as possible to the Power Stage device for lower power loss due to copper trace resistance. A shorter and wider PHASE trace to the inductor reduces the conduction loss. Preferably the Power S ...
... between the thermal and electrical performance of Power Stage. 3. Output inductor location should be as close as possible to the Power Stage device for lower power loss due to copper trace resistance. A shorter and wider PHASE trace to the inductor reduces the conduction loss. Preferably the Power S ...
Phasemaster 6 / 7 / 7S
... 28 amps at 50%, 70 amps at 8%, 200 amps @1% duty cycle Operator can save (write) 8 different weld schedules. Operator can save (write) 128 different weld schedules. Schedule protection Schedule protection feature protects schedules 1 feature protects schedules 1 through 127 from unauthorized or inad ...
... 28 amps at 50%, 70 amps at 8%, 200 amps @1% duty cycle Operator can save (write) 8 different weld schedules. Operator can save (write) 128 different weld schedules. Schedule protection Schedule protection feature protects schedules 1 feature protects schedules 1 through 127 from unauthorized or inad ...
GM862-QUAD / PY Hardware User Guide
... avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided shall be considered as mandatory, while the suggested hardware configurations shall not be considered mandatory, instead the information ...
... avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided shall be considered as mandatory, while the suggested hardware configurations shall not be considered mandatory, instead the information ...
download
... The regulator is shipped from the factory complete and ready to install. The agency responsible for installation must supply all necessary connectors, wire and conduit. The regulator is for indoor use only. It may be floor mounted, or mounted on a rack or shelf. Rack mounting schemes are the sole re ...
... The regulator is shipped from the factory complete and ready to install. The agency responsible for installation must supply all necessary connectors, wire and conduit. The regulator is for indoor use only. It may be floor mounted, or mounted on a rack or shelf. Rack mounting schemes are the sole re ...
Application note
... pair because it requires independent mode, and shifting the phase between each PWM would lead to the shoot through state. It is possible to dedicate another PWM pair to the second driver, but it requires more complicated SW and WCT pins. Better solution is to use PWM drivers which are driven only wi ...
... pair because it requires independent mode, and shifting the phase between each PWM would lead to the shoot through state. It is possible to dedicate another PWM pair to the second driver, but it requires more complicated SW and WCT pins. Better solution is to use PWM drivers which are driven only wi ...
RCD Type F Residual current protection for single phase
... A single phase frequency converter, also named inverter, is a commonly used electric drive which regulates the speed of an electric motor, operating on supply voltage and frequency. During normal operation, the current generated by a single phase inverter in the downstream section is the result of t ...
... A single phase frequency converter, also named inverter, is a commonly used electric drive which regulates the speed of an electric motor, operating on supply voltage and frequency. During normal operation, the current generated by a single phase inverter in the downstream section is the result of t ...
IL3115821590
... path in either PMOS devices or NMOS devices. Output node may evaluate from high to low or low to high or will remain unchanged. Output node will hold its value when Vclk and Vclk’ are in hold mode. Circuit nodes are not necessarily charging and discharging every clock cycle, reducing the switching a ...
... path in either PMOS devices or NMOS devices. Output node may evaluate from high to low or low to high or will remain unchanged. Output node will hold its value when Vclk and Vclk’ are in hold mode. Circuit nodes are not necessarily charging and discharging every clock cycle, reducing the switching a ...
UT350 1/4 DIN - McGoff
... Setpoint rate-of-change setting = off, or 0.0 to 100.0%/h or min of measured input range span. A PV tracking function operates automatically when the setpoint is changed, the power is turned on, or the mode is changed from manual to automatic. Direct/reverse action: The output increase/decrease dire ...
... Setpoint rate-of-change setting = off, or 0.0 to 100.0%/h or min of measured input range span. A PV tracking function operates automatically when the setpoint is changed, the power is turned on, or the mode is changed from manual to automatic. Direct/reverse action: The output increase/decrease dire ...
AD8112 数据手册DataSheet 下载
... surround all inputs and outputs to provide extra shielding for operation in the most demanding audio routing applications. With a differential gain and differential phase better than 0.1% and 0.1°, respectively, and a 0.1 dB flatness output of up to 10 MHz, the AD8112 is suitable for many video appl ...
... surround all inputs and outputs to provide extra shielding for operation in the most demanding audio routing applications. With a differential gain and differential phase better than 0.1% and 0.1°, respectively, and a 0.1 dB flatness output of up to 10 MHz, the AD8112 is suitable for many video appl ...
ERMCO Components
... Box have been designed for use in liquid filled transformers as a terminating block for current transformer leads. The Outlet Box is suitable for indoor or outdoor applications. It consists of a thermoset epoxy body with integrally cast-in brass threaded studs, a metal enclosure with all its corresp ...
... Box have been designed for use in liquid filled transformers as a terminating block for current transformer leads. The Outlet Box is suitable for indoor or outdoor applications. It consists of a thermoset epoxy body with integrally cast-in brass threaded studs, a metal enclosure with all its corresp ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.