Atmel LED Drivers MSL2160/MSL2161
... For video applications, the PWM LED drive signals synchronize to the LCD’s video frame timing via the PHI input, and to the LCD’s pixel timing via the GSC input. This synchronization eliminates beating artifacts. Suitability for LED backlight architectures is shown in Table 1. Area LED dimming for d ...
... For video applications, the PWM LED drive signals synchronize to the LCD’s video frame timing via the PHI input, and to the LCD’s pixel timing via the GSC input. This synchronization eliminates beating artifacts. Suitability for LED backlight architectures is shown in Table 1. Area LED dimming for d ...
Hall Effect Devices
... Moving the magnet away 1 mm I repeated the process. To get 1 mm I put eleven sheets of 20 pound bond printer paper together in 1" by 2" squares. Repeating this exercise I made 9 reading at 1 mm intervals, measured the output and graphed the result. Starting at 9 mm I reversed the process measuring t ...
... Moving the magnet away 1 mm I repeated the process. To get 1 mm I put eleven sheets of 20 pound bond printer paper together in 1" by 2" squares. Repeating this exercise I made 9 reading at 1 mm intervals, measured the output and graphed the result. Starting at 9 mm I reversed the process measuring t ...
Lesson – 24 : Practical Transformer
... Eddy current loss is essentially I 2 R loss occurring inside the core. The current is caused by the induced voltage in any conceivable closed path due to time varying field. Obviously to reduce eddy current loss in a material we have to use very thin plates instead of using solid block of material w ...
... Eddy current loss is essentially I 2 R loss occurring inside the core. The current is caused by the induced voltage in any conceivable closed path due to time varying field. Obviously to reduce eddy current loss in a material we have to use very thin plates instead of using solid block of material w ...
Chapter 4: Physical Installation
... Do not stand in water or on damp surfaces while working on the T/R set or controller. NWL Environmental Technologies, its parent corporation and affiliates will not be liable for death, injury or damages resulting from the unsafe installation or use of this device. ...
... Do not stand in water or on damp surfaces while working on the T/R set or controller. NWL Environmental Technologies, its parent corporation and affiliates will not be liable for death, injury or damages resulting from the unsafe installation or use of this device. ...
FSSD06 — SD/SDIO and MMC Two-Port Multiplexer Features Description
... The 1CMD, 2CMD, 1DAT[3:0], and 2DAT[3:0] ports do not have, internally, the system pull-up resistors as defined in the MMC or SD card system bus specifications. The system bus pull-up must be added external to the FSSD06. The value, within the specific specification limits, is a function of the indi ...
... The 1CMD, 2CMD, 1DAT[3:0], and 2DAT[3:0] ports do not have, internally, the system pull-up resistors as defined in the MMC or SD card system bus specifications. The system bus pull-up must be added external to the FSSD06. The value, within the specific specification limits, is a function of the indi ...
FSSD07 1-Bit / 4-Bit SD/SDIO and MMC Dual-Host Multiplexer
... baseband processor hosts to a common peripheral card or module, providing bi-directional support of the dualvoltage SD/SDIO or MMC cards available in the marketplace. Each host SDIO port has its own supply rail, such that hosts with different supplies can be interfaced to a common peripheral module ...
... baseband processor hosts to a common peripheral card or module, providing bi-directional support of the dualvoltage SD/SDIO or MMC cards available in the marketplace. Each host SDIO port has its own supply rail, such that hosts with different supplies can be interfaced to a common peripheral module ...
NX5P1000 1. General description Logic controlled high-side power switch
... The NX5P1000 is an advanced power switch and ESD- protection device for USB OTG applications. The device includes under voltage and over voltage lockout, over-current, over-temperature, reverse bias and in-rush current protection circuits. These circuits are designed to isolate a VBUS OTG voltage so ...
... The NX5P1000 is an advanced power switch and ESD- protection device for USB OTG applications. The device includes under voltage and over voltage lockout, over-current, over-temperature, reverse bias and in-rush current protection circuits. These circuits are designed to isolate a VBUS OTG voltage so ...
ABB Kuhlman 46000 Volt Instrument Transformers
... The SSVT-250 outdoor station service voltage transformer is rated for use on 46,000 volt systems with 250kV BIL. The unit is a station service voltage transformer with power and can be supplied with metering rated secondary winding(s). It provides a convenient and cost effective means of serving sma ...
... The SSVT-250 outdoor station service voltage transformer is rated for use on 46,000 volt systems with 250kV BIL. The unit is a station service voltage transformer with power and can be supplied with metering rated secondary winding(s). It provides a convenient and cost effective means of serving sma ...
MP4060 - Monolithic Power System
... Low-side control MOSFET drain to source Voltage VDS .................................-0.3 V to +30 V DAMP voltage .........................-0.3 V to +16.5 V ZCD current ...............................-5 mA to +5 mA Other analog inputs and outputs-0.3 V to +6.5 V Continuous power dissipation ...
... Low-side control MOSFET drain to source Voltage VDS .................................-0.3 V to +30 V DAMP voltage .........................-0.3 V to +16.5 V ZCD current ...............................-5 mA to +5 mA Other analog inputs and outputs-0.3 V to +6.5 V Continuous power dissipation ...
585 TECPak User's Manual
... located on the IPC, and the unit will power up. The AC Power LED should light, and the On / Error LED should remain dark. Control of the TECPak can be done two ways: use the RS232 or USB computer interfaces and control the instrument from the PC, or use the analog interface. This quick start guide u ...
... located on the IPC, and the unit will power up. The AC Power LED should light, and the On / Error LED should remain dark. Control of the TECPak can be done two ways: use the RS232 or USB computer interfaces and control the instrument from the PC, or use the analog interface. This quick start guide u ...
High-Speed, 4-A, 600-V High-Side Low
... Added Increase RHO and RLO, Reduce HS dV/dt image and description. ........................................................................... 31 ...
... Added Increase RHO and RLO, Reduce HS dV/dt image and description. ........................................................................... 31 ...
PAM8610 Description Pin Assignments
... V2P5, or 75% of its final value, the device turns on and the Class-D outputs start switching. The startup time is not critical for the best de-pop performance since any heard pop sound is the result of the Class-D output switching-on other than that of the startup time. However, at least a 0.47μF ca ...
... V2P5, or 75% of its final value, the device turns on and the Class-D outputs start switching. The startup time is not critical for the best de-pop performance since any heard pop sound is the result of the Class-D output switching-on other than that of the startup time. However, at least a 0.47μF ca ...
section 260575 – electrical for steam utility distribution
... Contactors: NEMA size 1 minimum, magnetically held, field replaceable coil and contacts, auxiliary contacts field installable and removable. Terminal temperature rise is not to exceed 50 degrees C in accordance with NEMA standards. Provide transient voltage surge suppressor across each contactor coi ...
... Contactors: NEMA size 1 minimum, magnetically held, field replaceable coil and contacts, auxiliary contacts field installable and removable. Terminal temperature rise is not to exceed 50 degrees C in accordance with NEMA standards. Provide transient voltage surge suppressor across each contactor coi ...
2C YWX - Diodes Incorporated
... support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. ...
... support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. ...
BQ24155 数据资料 dataSheet 下载
... USB-friendly switch-mode charge management device for single-cell Li-ion and Li-polymer batteries used in a wide range of portable applications. The charge parameters can be programmed through an I2C interface. The bq24155 integrates a synchronous PWM controller, power FETs, input current sensing, h ...
... USB-friendly switch-mode charge management device for single-cell Li-ion and Li-polymer batteries used in a wide range of portable applications. The charge parameters can be programmed through an I2C interface. The bq24155 integrates a synchronous PWM controller, power FETs, input current sensing, h ...
BDTIC www.BDTIC.com/infineon AN2011-04 MA3L080E07_EVAL Evaluation Adapter Board for EconoPACK
... Evaluation Driver Board for 3-Level EconoPACKTM 4 AN2011-03 Due to IGBT short circuit performance a maximum value of VGE ~15V is recommended. ...
... Evaluation Driver Board for 3-Level EconoPACKTM 4 AN2011-03 Due to IGBT short circuit performance a maximum value of VGE ~15V is recommended. ...
A. Internal Inductance
... 11 kV whereas the domestic consumers get power supply at 400-440 V. Note that the above figures are given for line-to-line voltages. Since domestic customers get single-phase supplies, they usually receive 230-250 V at their inlet points. While a domestic customer with a low power consumption gets a ...
... 11 kV whereas the domestic consumers get power supply at 400-440 V. Note that the above figures are given for line-to-line voltages. Since domestic customers get single-phase supplies, they usually receive 230-250 V at their inlet points. While a domestic customer with a low power consumption gets a ...
Contents
... and provides a real-time, user interface for the Opus Building Automation System (BAS). It enables users to monitor their BAS systems and make changes to the way their buildings are controlled. It serves as a centralized data collection, storage and reporting environment for critical BAS information ...
... and provides a real-time, user interface for the Opus Building Automation System (BAS). It enables users to monitor their BAS systems and make changes to the way their buildings are controlled. It serves as a centralized data collection, storage and reporting environment for critical BAS information ...
TRAX Transformer and Substation Test System
... to the transformer configuration is automatically performed for various vector groups. TRAX measures turns ratio, phase deviation and excitation current at the same time. Testing can be done at power frequency, or preferred and default, at a frequency different from the power frequency (55 Hz) to av ...
... to the transformer configuration is automatically performed for various vector groups. TRAX measures turns ratio, phase deviation and excitation current at the same time. Testing can be done at power frequency, or preferred and default, at a frequency different from the power frequency (55 Hz) to av ...
1N4148WS / BAV16WS
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
AN-8208 Introduction to Automotive Ignition Systems Introduction
... IGBT, a drive circuit, a spark plug, and a control unit. Normally, the control unit in an automobile is called the Engine Control Unit (ECU), from which the ignition command signal is created and sent to the ignition IGBT driver. The ECU determines the ignition timing based on the engine speed, temp ...
... IGBT, a drive circuit, a spark plug, and a control unit. Normally, the control unit in an automobile is called the Engine Control Unit (ECU), from which the ignition command signal is created and sent to the ignition IGBT driver. The ECU determines the ignition timing based on the engine speed, temp ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.