
Measuring transducers VI 400 for DC current VU 400 for DC voltage
... VI 400 and VU 400 are transducers converting measured quantities of current and voltage into a proportional load independent DC signal. The output signal can be connected to one or several receiving instruments such as panel indicators, recorders, controllers etc. The transducers have galvanic separ ...
... VI 400 and VU 400 are transducers converting measured quantities of current and voltage into a proportional load independent DC signal. The output signal can be connected to one or several receiving instruments such as panel indicators, recorders, controllers etc. The transducers have galvanic separ ...
ET 332b AC Electric Machines and Power
... Electromagnetic Principles and Devices Course Description and Prerequisites This course introduces the theory and operation of DC and AC machines with an emphasis on the testing and measurement of machine characteristics and parameters. Laboratory exercises will demonstrate the theoretical concepts ...
... Electromagnetic Principles and Devices Course Description and Prerequisites This course introduces the theory and operation of DC and AC machines with an emphasis on the testing and measurement of machine characteristics and parameters. Laboratory exercises will demonstrate the theoretical concepts ...
Brushless Motor Frequently Asked Questions 1. What is an outrunner motor?
... The 'normal' type of motor that you are probably familiar with is referred to as an 'inrunner', and the armature (stator) of the motor rotates inside the motor while the outer case of the motor stays fixed. An 'outrunner' motor has an inner stator that is stationary, while the outer case rotates. Th ...
... The 'normal' type of motor that you are probably familiar with is referred to as an 'inrunner', and the armature (stator) of the motor rotates inside the motor while the outer case of the motor stays fixed. An 'outrunner' motor has an inner stator that is stationary, while the outer case rotates. Th ...
BSX1-80/200/250IOV1HA
... electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing BME products, to comply with the standards of safety in making a safe design for the entire system, including redundancy, fire-prevention measures, and malfunction prevention, to preven ...
... electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing BME products, to comply with the standards of safety in making a safe design for the entire system, including redundancy, fire-prevention measures, and malfunction prevention, to preven ...
design_review - ECE Senior Design
... We’ve designed a ranging HIGH-SIDE current monitor, which attaches directly to their DC supply. We use a low-resistance sense resistor and amplifier to measure the sense voltage drop. We’ve begun characterization of this circuit on a mix of breadboard and PCB. Printed/No Lead board would mean better ...
... We’ve designed a ranging HIGH-SIDE current monitor, which attaches directly to their DC supply. We use a low-resistance sense resistor and amplifier to measure the sense voltage drop. We’ve begun characterization of this circuit on a mix of breadboard and PCB. Printed/No Lead board would mean better ...
Turning an MLA-2500B into a GS-35B HF RF Deck
... The remote Power supply is 0-5000 VDC @ 2 AMP, CCS. Running at 3500VDC no load, it pulls down to 300VDC under full load. Plate current is 600-700 mA and grid current runs about 200 mA with 100 watts drive. Idle grid current is 100 mA with a single 50 volt, 50 watt zener for bias. This PA is capable ...
... The remote Power supply is 0-5000 VDC @ 2 AMP, CCS. Running at 3500VDC no load, it pulls down to 300VDC under full load. Plate current is 600-700 mA and grid current runs about 200 mA with 100 watts drive. Idle grid current is 100 mA with a single 50 volt, 50 watt zener for bias. This PA is capable ...
Motors are Stepping Motors - Haydon Kerk Motion Solutions
... electrical. Hybrid, permanent magnet and variable reluctance stepping motors receive their steps from an electronic drive. The brush type DC motor receives its steps by a mechanical commutator and brushes. This assembly converts direct current into steps. The brushless DC motor uses magnetic h ...
... electrical. Hybrid, permanent magnet and variable reluctance stepping motors receive their steps from an electronic drive. The brush type DC motor receives its steps by a mechanical commutator and brushes. This assembly converts direct current into steps. The brushless DC motor uses magnetic h ...
ABB drives in chemical, oil and gas
... or for connection to an external input isolation transformer. The ACS 2000 is available with an Active Front End (AFE) to minimize harmonics. It is also available for four-quadrant operation for energy regeneration and reactive power compensation. ...
... or for connection to an external input isolation transformer. The ACS 2000 is available with an Active Front End (AFE) to minimize harmonics. It is also available for four-quadrant operation for energy regeneration and reactive power compensation. ...
m5zn_1ccd8e73e781118
... people really want from a power system Saudi annual electric energy consumption is about 212 billion kWh (about 7,862 kWh per person, which means on average we each use 0.79 kW of power continuously) Energy Units Joule = kWh – ...
... people really want from a power system Saudi annual electric energy consumption is about 212 billion kWh (about 7,862 kWh per person, which means on average we each use 0.79 kW of power continuously) Energy Units Joule = kWh – ...
Lecture_Induction Motors
... Induction motor speed So, the IM will always run at a speed lower than the synchronous speed The difference between the motor speed and the synchronous speed is called the Slip ...
... Induction motor speed So, the IM will always run at a speed lower than the synchronous speed The difference between the motor speed and the synchronous speed is called the Slip ...
XL270 AC-DC Series datasheet
... communications interface is available to allow up to six XL270s to communicate over the same bus using the PMBus protocol protocol. This interface allows routine remote control of the main outputs and the 12V fans fans. The host can also query the DSP for its output voltage and current plus the ambi ...
... communications interface is available to allow up to six XL270s to communicate over the same bus using the PMBus protocol protocol. This interface allows routine remote control of the main outputs and the 12V fans fans. The host can also query the DSP for its output voltage and current plus the ambi ...
ad-series-mains-power-supplies
... exchanges, remote antennae sites, ships, oil rigs etc. The units will accept either European 230Vac or US 115Vac inputs and are available as standard in 12V, 24V and 48V output configurations. Input is via a standard IEC-320 C13/14 power cord with UK, European or US mains plugs - please state your r ...
... exchanges, remote antennae sites, ships, oil rigs etc. The units will accept either European 230Vac or US 115Vac inputs and are available as standard in 12V, 24V and 48V output configurations. Input is via a standard IEC-320 C13/14 power cord with UK, European or US mains plugs - please state your r ...
PDF
... emission. This electricity generation is effected by physical and environmental parameters such as the solar radiation and cell temperature on PV cell. PV power supplied to the utility grid is gaining more and more attention nowadays, hence various standard mentioned by different grid monitoring aut ...
... emission. This electricity generation is effected by physical and environmental parameters such as the solar radiation and cell temperature on PV cell. PV power supplied to the utility grid is gaining more and more attention nowadays, hence various standard mentioned by different grid monitoring aut ...
ON DELAY | INLINE (SERIES CONNECTION)
... Three time ranges are available: 0.1 – 102.3 seconds, 1 – 1,023 seconds and 10 – 10,230 seconds. Programming is accomplished through the use of a 10-position DIP-switch. Each position is marked with a binary time increment. The required delay is selected by moving the switch of each increment to the ...
... Three time ranges are available: 0.1 – 102.3 seconds, 1 – 1,023 seconds and 10 – 10,230 seconds. Programming is accomplished through the use of a 10-position DIP-switch. Each position is marked with a binary time increment. The required delay is selected by moving the switch of each increment to the ...
“Fuzzy Logic Speed Controllers Using FPGA Technique For Three
... Power devices are the key elements of a power converter. The commonly used devices are: (1) Power Diode (2) Silicon-Controlled Rectifier (SCR) or Thyristor (3) Gate Turn-off Thyristor (GTO) (4) Power Bipolar Junction Transistor (Power BJT) (5) Power Metal-Oxide Field-Effect Transistor (Power MOSFET) ...
... Power devices are the key elements of a power converter. The commonly used devices are: (1) Power Diode (2) Silicon-Controlled Rectifier (SCR) or Thyristor (3) Gate Turn-off Thyristor (GTO) (4) Power Bipolar Junction Transistor (Power BJT) (5) Power Metal-Oxide Field-Effect Transistor (Power MOSFET) ...
ELECTRIC TRACTION
... The equipments should be capable of withstanding large temporary loads. Speed control should be easy. Pollution free. Low initial and maintenance cost. The locomotive should be self contain and able to run on any route. ...
... The equipments should be capable of withstanding large temporary loads. Speed control should be easy. Pollution free. Low initial and maintenance cost. The locomotive should be self contain and able to run on any route. ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.