• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CAPS_ESRDC_26May2009_Overview
CAPS_ESRDC_26May2009_Overview

... Real and reactive power distribution between DC source and energy storage element Reduce converter switching loss and increase output voltage boost ratio High power density and high efficiency ...
Maxstar 150 S
Maxstar 150 S

... Low OCV Stick is a simple design that reduces the open-circuit voltage to 12-16 volts when the welding power source is not in use. This circuit design is now built into the Maxstar 150 S eliminating the need for add-on voltage reducers. ...
***** 1
***** 1

... Non-inductive filters. To design an active filter only resistors and capacitors are required, inductance is not required. This feature is particularly important when operating at relatively low frequencies (<10 Hz), otherwise it would require larger inductance. ...
MAGNASTART Slipring Motor Starters TM P O W E R
MAGNASTART Slipring Motor Starters TM P O W E R

... Tappings at 100%, 84% and 56% per coil allow a choice of star and delta impedances from 100% down to 3% in 17 steps. 7. The Thermal Overload Cut-out should be wired to trip the starting system in case of overload (contacts open). 8. On the M30, M45, M90, M125 and M175 the mounting channels can be re ...
Minimum Energy Sub-Threshold CMOS Operation Given Yield
Minimum Energy Sub-Threshold CMOS Operation Given Yield

GZ3512221228
GZ3512221228

... 30° with respect to ebn. This means that the zero crossing points of Vao, Vba and -Vbo can be used to commutate the currents in phase A, B and C respectively. Table II indicate the detailed Switching sequences of four switch converter. Due to the characteristics of BLDC motor, only two phases need t ...
Electricity Basics for Boiler Operation - Cleaver
Electricity Basics for Boiler Operation - Cleaver

... made up of a balance of protons and neutrons. When an electron is knocked out of its orbit, which is not that difficult, it is considered a free electron. When this occurs, the balance ends and the atom becomes positive, seeking a negative replacement. So, essentially electricity is the flow of elec ...
Neuromorphic computation - New Challenges in the European Area
Neuromorphic computation - New Challenges in the European Area

... Voltage (V) ...
PMT Circuits
PMT Circuits

... Decoupling capacitors can increase the linear operating region ...
AC-DC Power Transmision
AC-DC Power Transmision

Selecting Electric Motors
Selecting Electric Motors

Bipolar transistors II, Page 1  Bipolar Transistors II
Bipolar transistors II, Page 1 Bipolar Transistors II

CM Tiny - Lontech
CM Tiny - Lontech

... The CM Tiny is the smallest industrial charging generator for static bonding applications. The unit has fully integrated high voltage parts and only needs a 24V DC supply. The housing is compact, robust and only weighs 500 grams which makes it perfect for small machines and applications with moving ...
Selection and Modeling of PMBLDC Motor for Torque Ripple
Selection and Modeling of PMBLDC Motor for Torque Ripple

... and its back-EMF is shown in Fig. 4. The back-EMF is obtained by experiment and inductances of each phase are measured by digital LCR meter. The 500WBLDC motor is simulated by the Mat lab with the parameters of that is not only the BLDC motor but also the inverter. The current waveform of 500 W BLDC ...
SPH 4A - mackenziekim
SPH 4A - mackenziekim

Achieve 20-30% power savings in low-power
Achieve 20-30% power savings in low-power

... before placing orders. TI assumes no liability for applications assistance, customer’s applications or product designs, software performance, or infringement of patents. The publication of information regarding any other company’s products or services does not constitute TI’s approval, ...
Current Intensity, Potential Difference and Ohm`s law
Current Intensity, Potential Difference and Ohm`s law

... 19. Wires create resistance to the flow of an electric current. This means that there is a drop in the voltage and that the wire heats up. An electrical circuit consists of a power source, an electrical device and 100 m of wire, as shown in the diagram below. ...
10-Output Power Panel for Serena® and Sivoia® QS Triathlon
10-Output Power Panel for Serena® and Sivoia® QS Triathlon

... • Class 2, 12 V power supply powers up to 10 remote-controlled shades • Universal input voltage: 120-240V~ 50/60 Hz • Electronic over-current and over-temperature protection • Simple wiring scheme uses 2-conductor, low voltage link to provide power • Compliant with U. S. Department of Energy Ef ...
- Krest Technology
- Krest Technology

... Flexible AC Transmission Systems (FACTS) devices can be used for power flow control in AC transmission grids, improving power line utilization and performance. Nowadays, Unified Power Flow Controllers (UPFC) are one of the most useful FACTS, allowing the simultaneous control of the bus voltage and l ...
Barzyk, Dopiera: Significant
Barzyk, Dopiera: Significant

... statistics state on 1997, most of legal acts mentioned above has the status of instructions; the regulations being only the subject to recommendations and indications but not the standards. The coming process of Poland's integration with European Union would require new approach (creation) to Power ...
Troubleshooting an EC Fan (Non Modbus) in a
Troubleshooting an EC Fan (Non Modbus) in a

... between the control wiring on the electrical panel and unit cabinet. Terminals provide access for measuring voltage while troubleshooting. D. (ID8,ID11 and ID12) are the 24VAC+ input terminals for the Fan Alarm Circuit. The E2 will alarm on loss of voltage. For example: No voltage at ID12 will trigg ...
E831 Miniature Piezo Driver  Piezo Control
E831 Miniature Piezo Driver Piezo Control

... OEM Module, Power Supply for up to 3 Axes steadystate operation and the power consumption depends on the operating frequency, high-powered amplifiers are not required for many applications. With a peak output current of 100 mA (sink/source) the E-831 is well-suited for switching applications and fas ...
ICL7107 Digital LED Voltmeter
ICL7107 Digital LED Voltmeter

Motor Starters - MD Anderson Cancer Center
Motor Starters - MD Anderson Cancer Center

AK01415111514
AK01415111514

... the voltage at port a–b (Vab) in Fig. 8 is mainly mVdch sin (nωf t) and the switching harmonics. Therefore, there is no net active power transfer across the port a–b. Hence, the current source, i.e., the main square-wave inverter delivers the complete conduction losses of each harmonic cell. Due to ...
< 1 ... 1209 1210 1211 1212 1213 1214 1215 1216 1217 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report