
DB32637643
... the compensation not only of current harmonics produced by fluctuating loads, but also of reactive power and unbalance of non-linear and distorting loads[4],[5]. At low voltage levels, conventional two level inverters are used. At medium voltage levels, the conventional two level inverters either re ...
... the compensation not only of current harmonics produced by fluctuating loads, but also of reactive power and unbalance of non-linear and distorting loads[4],[5]. At low voltage levels, conventional two level inverters are used. At medium voltage levels, the conventional two level inverters either re ...
pptx - PMBus
... – AVSBus is an application specific protocol to allow a powered device such as an ASIC, FPGA or Processor to control its own voltage for power savings – PMBus is an open standard protocol that defines a means of communicating with power conversion and other devices allowing effective configuration a ...
... – AVSBus is an application specific protocol to allow a powered device such as an ASIC, FPGA or Processor to control its own voltage for power savings – PMBus is an open standard protocol that defines a means of communicating with power conversion and other devices allowing effective configuration a ...
ECET 3500
... ___True___ At full rated voltage, a DC machine will typically draw a very large current at “start-up”. ___False___ The DC field winding of a DC machine is mounted on the rotor of the machine. ___False___ Increasing the field current in a shunt-excited DC motor will typically cause an increase in spe ...
... ___True___ At full rated voltage, a DC machine will typically draw a very large current at “start-up”. ___False___ The DC field winding of a DC machine is mounted on the rotor of the machine. ___False___ Increasing the field current in a shunt-excited DC motor will typically cause an increase in spe ...
Synchronous Machines
... The stator of three-phase synchronous machine has a three-phase distributed winding similar to that of the three-phase induction machine. The stator winding, which is connected to the ac supply, is sometimes called the armature winding. It is designed for high voltage and current. The rotor has a wi ...
... The stator of three-phase synchronous machine has a three-phase distributed winding similar to that of the three-phase induction machine. The stator winding, which is connected to the ac supply, is sometimes called the armature winding. It is designed for high voltage and current. The rotor has a wi ...
- Eagle Harbor Technologies, Inc.
... magnetic fusion science. High voltage and current supplies are needed to mitigate instabilities in all experiments as well as disruption events in large scale tokamaks for steady-state operation. Silicon carbide (SiC) MOSFETs offer many advantages over IGBTs including lower drive energy requirements ...
... magnetic fusion science. High voltage and current supplies are needed to mitigate instabilities in all experiments as well as disruption events in large scale tokamaks for steady-state operation. Silicon carbide (SiC) MOSFETs offer many advantages over IGBTs including lower drive energy requirements ...
Diode CH/S
... (4) Write on uses of normal diode in engineering applications, and then Show the difference between the characteristics of silicon and germanium diode. Ans. / Modern diodes are semiconductor components, which have attained supreme importance in electrical engineering and electronics thanks to their ...
... (4) Write on uses of normal diode in engineering applications, and then Show the difference between the characteristics of silicon and germanium diode. Ans. / Modern diodes are semiconductor components, which have attained supreme importance in electrical engineering and electronics thanks to their ...
LP121X04 - Spectrah
... characteristics of the DC-AC inverter. So all the parameters of an inverter should be carefully designed so as not to produce too much leakage current from high-voltage output of the inverter. When you design or order the inverter, please make sure unwanted lighting caused by the mismatch of the lam ...
... characteristics of the DC-AC inverter. So all the parameters of an inverter should be carefully designed so as not to produce too much leakage current from high-voltage output of the inverter. When you design or order the inverter, please make sure unwanted lighting caused by the mismatch of the lam ...
speed control of dc motor using combined armature and field control
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
... poles). In all DC motors, except permanent magnet brushless motors, current must be conducted to the armature windings by passing current through carbon brushes that slide over a set of copper surfaces called a commutator, which is mounted on the rotor. The commutator bars are soldered to armature c ...
Advanced Computer Architecture
... with two cores—one for measurements and one for protection purposes. The measurement core will give accurate measurements during normal power system operation, but will saturate for the much higher fault currents. The protection core, on the other hand, is not capable of providing accurate measu ...
... with two cores—one for measurements and one for protection purposes. The measurement core will give accurate measurements during normal power system operation, but will saturate for the much higher fault currents. The protection core, on the other hand, is not capable of providing accurate measu ...
CM-MPS.21S
... CM-MPS.21S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC The CM-MPS.21S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 180-280 V AC 50/60 Hz and has a 2 c/o (SPDT) output wi ...
... CM-MPS.21S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC The CM-MPS.21S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 180-280 V AC 50/60 Hz and has a 2 c/o (SPDT) output wi ...
Down East Microwave
... amateur33-cm band. It will provide up to {O watts power output for 1O watts drive. It requires external T/R switching and can be used by itself or as a driver for a higherpowertube amplifier. 2) The amplifier requires 13.8-voltsdc at 5.5 amps maximum for the collector supply and a bias supply of l3. ...
... amateur33-cm band. It will provide up to {O watts power output for 1O watts drive. It requires external T/R switching and can be used by itself or as a driver for a higherpowertube amplifier. 2) The amplifier requires 13.8-voltsdc at 5.5 amps maximum for the collector supply and a bias supply of l3. ...
[PDF]
... throughput even at a low MHz clock rates. The flexibility of the FPGA allows for even higher performance by trading off precision and range in the number format for an increased number of parallel arithmetic units. This has driven a new type of processing called reconfigurable computing, where time ...
... throughput even at a low MHz clock rates. The flexibility of the FPGA allows for even higher performance by trading off precision and range in the number format for an increased number of parallel arithmetic units. This has driven a new type of processing called reconfigurable computing, where time ...
GMAW Power Sources
... GMAW process are often referred to as having a “self regulating” welding arc. In order to maintain this self regulating arc, the following five items are necessary: The proper voltage setting for a given type and size electrode. Current going through the electrode (a good ground). Appropriate ...
... GMAW process are often referred to as having a “self regulating” welding arc. In order to maintain this self regulating arc, the following five items are necessary: The proper voltage setting for a given type and size electrode. Current going through the electrode (a good ground). Appropriate ...
XC9500XL CPLD Automotive IQ Family ( ver1.3, 434 KB
... 1. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum ...
... 1. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum ...
EasySpeed 3G3JE Series Datasheet
... brake the motor. When stopping, DC braking operates at the DC braking standard frequency and below. ...
... brake the motor. When stopping, DC braking operates at the DC braking standard frequency and below. ...
PDF
... Filter inductance is replaced by a third order LCL filter for better switching ripple attenuation can be achieved during operation [7]. To generate reference current fuzzy logic are also introduced. Fuzzy logic cannot provide accurate results at dynamic condition because the membership function and ...
... Filter inductance is replaced by a third order LCL filter for better switching ripple attenuation can be achieved during operation [7]. To generate reference current fuzzy logic are also introduced. Fuzzy logic cannot provide accurate results at dynamic condition because the membership function and ...
FAN2012 1.5 A Low-Voltage, Current-Mode Synchronous PWM Buck Regulator
... synchronous Pulse Width Modulated (PWM) currentmode DC-DC converter designed for low-voltage applications. It provides up to 1.5 A continuous-load current from the 4.5 V to 5.5 V input. The output voltage is adjustable over a wide range of 0.8 V to 3.5 V by means of an external voltage divider. ...
... synchronous Pulse Width Modulated (PWM) currentmode DC-DC converter designed for low-voltage applications. It provides up to 1.5 A continuous-load current from the 4.5 V to 5.5 V input. The output voltage is adjustable over a wide range of 0.8 V to 3.5 V by means of an external voltage divider. ...
Sunmodule Plus 285W mono
... Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than o ...
... Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than o ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.