• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
User`s Guide UPS 20 - 40 kVA, 230/400 V 50/60 Hz output (3
User`s Guide UPS 20 - 40 kVA, 230/400 V 50/60 Hz output (3

... Address any inquiries about the UPS and battery cabinet to the local office or agent authorised by the manufacturer. Please quote the type code and the serial number of the equipment. ...
Quad-Core Intel® Xeon® Processor 5400 Series
Quad-Core Intel® Xeon® Processor 5400 Series

... PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or character ...
MAX6365–MAX6368 SOT23, Low-Power µP Supervisory Circuits with Battery Backup and Chip-Enable Gating
MAX6365–MAX6368 SOT23, Low-Power µP Supervisory Circuits with Battery Backup and Chip-Enable Gating

... maintain data or low-power operation for CMOS RAM, CMOS µPs, real-time clocks, and other digital logic when the main supply fails. 3) Provide memory write protection through internal chip-enable gating during supply or processor faults. 4) Include one of the following options: a manual reset input ( ...
MAX803/MAX809/ MAX810 3-Pin
MAX803/MAX809/ MAX810 3-Pin

... supervisory circuits used to monitor the power supplies in μP and digital systems. They provide excellent circuit reliability and low cost by eliminating external components and adjustments when used with +5V, +3.3V, +3.0V, or +2.5V powered circuits. These circuits perform a single function: they as ...
Front-end Signal Conditioners Owner`s Guide
Front-end Signal Conditioners Owner`s Guide

... The Front Panel���������������������������������������������������������������������������������������������������������������99 The Back Panel �������������������������������������������������������������������������������������������������������������101 Connecting to the PowerLab�������������� ...
MAX803/MAX809/MAX810 3-Pin Microprocessor Reset Circuits General Description ____________________________Features
MAX803/MAX809/MAX810 3-Pin Microprocessor Reset Circuits General Description ____________________________Features

... supervisory circuits used to monitor the power supplies in µP and digital systems. They provide excellent circuit reliability and low cost by eliminating external components and adjustments when used with +5V, +3.3V, +3.0V, or +2.5V powered circuits. These circuits perform a single function: they as ...
Model 42i-LS - User Manual
Model 42i-LS - User Manual

... 27 Forge Parkway Franklin, MA 02038 ...
- IEEE Mentor
- IEEE Mentor

CCD77-00 Back Illuminated High Performance IMO Device
CCD77-00 Back Illuminated High Performance IMO Device

... the input gate should be pulsed high during the period when A11 is high and the input diode should be adjusted for the required charge injection. Typical uses for such charge injection include assessing charge transfer efficiency, and the measurement of output responsivity using the reset drain curr ...
Wildcat (BL2000) - Digi International
Wildcat (BL2000) - Digi International

... 1.3 Development and Evaluation Tools 1.3.1 Tool Kit A Tool Kit contains the hardware essentials you will need to use your own BL2000 singleboard computer. The items in the Tool Kit and their use are as follows: • Getting Started instructions. • Dynamic C CD-ROM, with complete product documentation ...
gesis ELECTRONIC - Wieland Electric
gesis ELECTRONIC - Wieland Electric

... Brand: Wieland Electric GmbH Type: KNX FLEX-BAS SP Z ...
MEASUREMENT, SUPPRESSION, AND
MEASUREMENT, SUPPRESSION, AND

KEI 2302, 2306 Service
KEI 2302, 2306 Service

... The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with non-hazardous voltages, there are situations where hazardous conditions may be present. This product is intended for ...
ENERGY LABORATORY
ENERGY LABORATORY

... Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 20 students post, but we can recommend the number of units for 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation ...
4017, 4022
4017, 4022

6RA70 Series Base Drive Instruction Manual
6RA70 Series Base Drive Instruction Manual

... On single-quadrant converters, a fully controlled three-phase bridge supplies the armature. On fourquadrant converters, two fully controlled three-phase bridges are connected in an inverse-parallel connection to allow both positive and negative armature current. For the field converter, a singlephas ...
Operating And Service Instructions - AT30 Charger
Operating And Service Instructions - AT30 Charger

0.9 Mb PDF - David Kleinfeld
0.9 Mb PDF - David Kleinfeld

... To find the maximum load resistance that keeps us in the active zone, we first rewrite the load line as an expression for VDS, i.e., VDS = VDD - IDSS RLoad Noting that VDS > - VGS(off), this implies -VGS(off) > VDD - IDSS RLoad or ...
Voltage Regulators - Aeroflex Microelectronic Solutions
Voltage Regulators - Aeroflex Microelectronic Solutions

... 2/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating effects are covered under the specification for thermal regulation. Measurements taken at the output lead must be adjusted for lead resistance. 3/ Not tes ...
national transmission
national transmission

... We expect you to know and apply them on every job. As a matter of fact, you would be wise to apply them off the job as well. Looking at the safety principles in sequence, which, by the way, is how they must always be applied, you will observe that principles - 1, 2, and 3 concentrate on the identifi ...
E2 User Manual - Emerson Climate Technologies
E2 User Manual - Emerson Climate Technologies

... The information contained in this manual has been carefully checked and is believed to be accurate. However, Computer Process Controls, Inc. assumes no responsibility for any inaccuracies that may be contained herein. In no event will Computer Process Controls, Inc. be liable for any direct, indirec ...
615 series ANSI Technical Manual
615 series ANSI Technical Manual

Dual-Core Intel® Xeon® Processor 5100 Series Datasheet
Dual-Core Intel® Xeon® Processor 5100 Series Datasheet

... reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Dual-Core Intel® Xeon® Processor 5100 Series may contain design defects or errors known as errata which may cause the product to deviate from p ...
QUOTATION Digital oscilloscope
QUOTATION Digital oscilloscope

... Channel 1; Channel 3* *four channel models only Channel 2; Channel 4* *four channel models only ...
Liebert eXM User Manual–60-100kVA, 50/60Hz ®
Liebert eXM User Manual–60-100kVA, 50/60Hz ®

< 1 2 3 4 5 6 7 8 9 10 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report