Ω MAX4719 20 , 300MHz Bandwidth, Dual SPDT Analog
... Analog Signal Levels The on-resistance of the MAX4719 changes very little for analog input signals across the entire supply voltage range (see the Typical Operating Characteristics). The switches are bidirectional, so the NO_, NC_, and COM_ pins can be either inputs or outputs. ...
... Analog Signal Levels The on-resistance of the MAX4719 changes very little for analog input signals across the entire supply voltage range (see the Typical Operating Characteristics). The switches are bidirectional, so the NO_, NC_, and COM_ pins can be either inputs or outputs. ...
Here - Analogue Haven
... 10. Saw/Ramp wave Knob: this is a level knob to control if you want saw or ramp for output. It acts as an attenu-inverter. 11. VCO/LFO Toggle switch: this switch determines the overall mode of the module. Use VCO mode for tones, LFO mode to control other modules in a slower rate. 12. FM AC/DC Toggle ...
... 10. Saw/Ramp wave Knob: this is a level knob to control if you want saw or ramp for output. It acts as an attenu-inverter. 11. VCO/LFO Toggle switch: this switch determines the overall mode of the module. Use VCO mode for tones, LFO mode to control other modules in a slower rate. 12. FM AC/DC Toggle ...
SNG
... cables can be installed under wall, or in narrow installation mouldings. The parallel tapping can be done in the installation moulding. Before sticking the piezo-elements, the flexible double-line cables must be properly soldered to the elements. The soldering must be done as fast as possible always ...
... cables can be installed under wall, or in narrow installation mouldings. The parallel tapping can be done in the installation moulding. Before sticking the piezo-elements, the flexible double-line cables must be properly soldered to the elements. The soldering must be done as fast as possible always ...
Datasheet - Distech Controls
... Temperature or C02, temperature & RH sensing in one housing. Using a non-dispersive infrared sensor for measuring CO2 concentrations and utilizing microprocessor-based electronics, the unique self-calibration algorithm offers long-term stability and accuracy. They are also fitted with a temperature ...
... Temperature or C02, temperature & RH sensing in one housing. Using a non-dispersive infrared sensor for measuring CO2 concentrations and utilizing microprocessor-based electronics, the unique self-calibration algorithm offers long-term stability and accuracy. They are also fitted with a temperature ...
MAX14589E/MAX14594E High-Density, ±5V Capable DPDT Analog Switches General Description Benefits and Features
... Note 4: The same limits apply for VCOM_ = -5.5V to +5.5V and are guaranteed by design. Note 5: DRON(MAX) = |RON(CH1) - RON(CH2)|. Note 6: Guaranteed by design; not production tested. Note 7: Flatness is defined as the difference between the maximum and minimum value of on-resistance, as measured ...
... Note 4: The same limits apply for VCOM_ = -5.5V to +5.5V and are guaranteed by design. Note 5: DRON(MAX) = |RON(CH1) - RON(CH2)|. Note 6: Guaranteed by design; not production tested. Note 7: Flatness is defined as the difference between the maximum and minimum value of on-resistance, as measured ...
MT-FD 6 - Newmar
... CAUTION: Install a fuse or circuit breaker on the positive (+) battery power feed wire as close to the battery as possible in order to protect the input power feed wires. Size fuse or circuit breaker 125-150% of the maximum load current. For single MT-FD 6 installations, see Table 1 “Recommended Inp ...
... CAUTION: Install a fuse or circuit breaker on the positive (+) battery power feed wire as close to the battery as possible in order to protect the input power feed wires. Size fuse or circuit breaker 125-150% of the maximum load current. For single MT-FD 6 installations, see Table 1 “Recommended Inp ...
MAX4714 0.8 , Low-Voltage, Single-Supply SPDT Analog Switch in SC70
... SPDT Analog Switch in SC70 The MAX4714 is a low on-resistance, low-voltage single-pole/double-throw (SPDT) analog switch that operates from a single +1.6V to +3.6V supply. The MAX4714 has break-before-make switching. This device also has fast switching speeds (tON = 18ns, max, tOFF = 12ns, max). Whe ...
... SPDT Analog Switch in SC70 The MAX4714 is a low on-resistance, low-voltage single-pole/double-throw (SPDT) analog switch that operates from a single +1.6V to +3.6V supply. The MAX4714 has break-before-make switching. This device also has fast switching speeds (tON = 18ns, max, tOFF = 12ns, max). Whe ...
MAX4620/MAX4630/MAX4640 ±15kV ESD-Protected, Low-Voltage, Quad, SPST, CMOS Analog Switches General Description
... without latchup or damage. Each switch can handle Rail-to-Rail® analog signals. The off-leakage current is 0.5nA at +25°C. These analog switches are suitable for low-distortion audio applications and are the preferred solution over mechanical relays in automated test equipment or applications where ...
... without latchup or damage. Each switch can handle Rail-to-Rail® analog signals. The off-leakage current is 0.5nA at +25°C. These analog switches are suitable for low-distortion audio applications and are the preferred solution over mechanical relays in automated test equipment or applications where ...
smartDIM SM
... The smartDIM SM can be operated without connecting any sensor. In this case connected DSI devices can be dimmed and switched ON/OFF manually via external mains rated push to make switch(es). Either a single- or double-gang push to make switch can be used. Using a number of push to make switches in p ...
... The smartDIM SM can be operated without connecting any sensor. In this case connected DSI devices can be dimmed and switched ON/OFF manually via external mains rated push to make switch(es). Either a single- or double-gang push to make switch can be used. Using a number of push to make switches in p ...
Switch
In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.