
AP2337 1.0A SINGLE CHANNEL CURRENT-LIMITED LOAD SWITCH Description
... The AP2337 is single channel current-limited integrated highside power switches optimized for hot-swap applications. The devices have fast short-circuit response time for improved overall system robustness and provide a complete protection solution for application subject to heavy capacitive loads a ...
... The AP2337 is single channel current-limited integrated highside power switches optimized for hot-swap applications. The devices have fast short-circuit response time for improved overall system robustness and provide a complete protection solution for application subject to heavy capacitive loads a ...
Ringing Reduction Techniques for NexFET High
... The design of switching converters with high performance MOSFET’s such as those found in the NexFETTM product line require special attention to detail to maximize the effectiveness of the devices and optimize the overall performance of the switching function. Consideration of the challenges of worki ...
... The design of switching converters with high performance MOSFET’s such as those found in the NexFETTM product line require special attention to detail to maximize the effectiveness of the devices and optimize the overall performance of the switching function. Consideration of the challenges of worki ...
MAX8586 Single 1.2A USB Switch in 3mm x 3mm TDFN General Description
... Do not use RISET values below 26kΩ because the maximum current rating of the device may be exceeded. RISET values larger than 60kΩ are not recommended and do not provide a lower limit current than 500mA. If the output drops below 1V (typ), the MAX8586 shifts to a short-circuit current-limit threshol ...
... Do not use RISET values below 26kΩ because the maximum current rating of the device may be exceeded. RISET values larger than 60kΩ are not recommended and do not provide a lower limit current than 500mA. If the output drops below 1V (typ), the MAX8586 shifts to a short-circuit current-limit threshol ...
vertical lift design specifications
... a) Platform lighting integral to the platform control panel, automatically activated during travel and for at least 8 seconds after platform arrives at the designated landing. b) Grounded electrical system with upper, lower, and final limit switches and 24VDC operating controls. c) Non-slip platform ...
... a) Platform lighting integral to the platform control panel, automatically activated during travel and for at least 8 seconds after platform arrives at the designated landing. b) Grounded electrical system with upper, lower, and final limit switches and 24VDC operating controls. c) Non-slip platform ...
instructions for knopp phase sequence
... Use of the Knopp Phase Sequence Indicator when one connects three-phase motors and generators, protects apparatus and enhances service efficiency. By determining which terminals of a newly installed polyphase power circuit are to be connected to the sequence identified motor terminals, one eliminate ...
... Use of the Knopp Phase Sequence Indicator when one connects three-phase motors and generators, protects apparatus and enhances service efficiency. By determining which terminals of a newly installed polyphase power circuit are to be connected to the sequence identified motor terminals, one eliminate ...
DETECTTM Occupancy
... the detection area according to Figures 2 and 3. The switching delay should not be used when the DETECT O is used for simultaneous light control. Corner placement of the DETECT O V110 in one corner and for the DETECT O T360 in the centre of the ceiling is recommended. ...
... the detection area according to Figures 2 and 3. The switching delay should not be used when the DETECT O is used for simultaneous light control. Corner placement of the DETECT O V110 in one corner and for the DETECT O T360 in the centre of the ceiling is recommended. ...
DG540-2.pdf
... Use extensive ground planes on double sided PCB, separating adjacent signal paths. Multilayer PCB is even better. ...
... Use extensive ground planes on double sided PCB, separating adjacent signal paths. Multilayer PCB is even better. ...
Charge needs a continuous path to flow.
... Most modern homes do not use fuses. Instead, they use safety devices called circuit breakers. Circuit breakers, unlike fuses, do not have to be replaced every time they open the circuit. Like fuses, circuit breakers automatically open the circuit when too much charge flows through it. If the circuit ...
... Most modern homes do not use fuses. Instead, they use safety devices called circuit breakers. Circuit breakers, unlike fuses, do not have to be replaced every time they open the circuit. Like fuses, circuit breakers automatically open the circuit when too much charge flows through it. If the circuit ...
Manual MultiPlus Compact 12 | 2000 | 80-50 120V
... Traction batteries may require regular equalisation charging. In the equalisation mode, the MultiPlus will charge with increased voltage for one hour (1V above the absorption voltage for a 12V battery, 2V for a 24V battery). The charging current is then limited to 1/4 of the set value. The “bulk” an ...
... Traction batteries may require regular equalisation charging. In the equalisation mode, the MultiPlus will charge with increased voltage for one hour (1V above the absorption voltage for a 12V battery, 2V for a 24V battery). The charging current is then limited to 1/4 of the set value. The “bulk” an ...
Heliarc® 252 ac/dc and Heliarc® 352 ac/dc
... This equipment will perform in conformity with the description thereof contained in this manual and accompanying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instructions provided. This equipment must be checked periodically. Malfunctioning or poorly ...
... This equipment will perform in conformity with the description thereof contained in this manual and accompanying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instructions provided. This equipment must be checked periodically. Malfunctioning or poorly ...
Switch

In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.