
High Voltage Power Supplies
... Make Precise Current Measurements Lower Than 1µA Use a sensitive Keithley measurement instrument, such as a Keithley SourceMeter® Source Measure Unit (SMU) instrument, to measure current drawn by the device under test (DUT) that is below the sensitivity of the Series 2290 Power Supplies. Keithley So ...
... Make Precise Current Measurements Lower Than 1µA Use a sensitive Keithley measurement instrument, such as a Keithley SourceMeter® Source Measure Unit (SMU) instrument, to measure current drawn by the device under test (DUT) that is below the sensitivity of the Series 2290 Power Supplies. Keithley So ...
Shunt hybrid active power filter for harmonic mitigation: A practical
... by other loads in the grid. Also the probability of generating series resonances with the power system’s equivalent reactance reduces power system stability. Another disadvantage of PPF is related to the small design tolerances acceptable in the values of L or C, which can modify significantly the f ...
... by other loads in the grid. Also the probability of generating series resonances with the power system’s equivalent reactance reduces power system stability. Another disadvantage of PPF is related to the small design tolerances acceptable in the values of L or C, which can modify significantly the f ...
TRANSISTOR SWITCHING - University of Michigan
... significant only for very fast changes. These device-specific contributions are considered elsewhere; ordinarily they are of little import for significant time intervals less than (roughly) 10 to 100 nanoseconds. Switching is examined here in the context of a bipolar junction transistor circuit. Swi ...
... significant only for very fast changes. These device-specific contributions are considered elsewhere; ordinarily they are of little import for significant time intervals less than (roughly) 10 to 100 nanoseconds. Switching is examined here in the context of a bipolar junction transistor circuit. Swi ...
FR015L3EZ Low-Side Reverse Bias / Reverse Polarity Protector
... Semiconductor products, including compliance with all laws, regulations and safety requirements or standards, regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or specifications can and d ...
... Semiconductor products, including compliance with all laws, regulations and safety requirements or standards, regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or specifications can and d ...
DIMD10A Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
modal liquid crystal wavefront correctors
... It is possible to use the actual electrical properties of the LC cell produce more complicated voltage profiles across the device [5]. In this case it is necessary to use a high resistance top electrode, and higher frequency control voltages, as shown in figures 2 and 3. The LC cell can be modeled s ...
... It is possible to use the actual electrical properties of the LC cell produce more complicated voltage profiles across the device [5]. In this case it is necessary to use a high resistance top electrode, and higher frequency control voltages, as shown in figures 2 and 3. The LC cell can be modeled s ...
MP2161 - Monolithic Power System
... transient, MP2161 fixes the minimum off time to be 60ns. However, this minimum off time limit will not affect operation of MP2161 in steady state in any way. Light Load Operation In light load condition, MP2161 uses a proprietary control scheme to save power and improve efficiency. The MP2161 will t ...
... transient, MP2161 fixes the minimum off time to be 60ns. However, this minimum off time limit will not affect operation of MP2161 in steady state in any way. Light Load Operation In light load condition, MP2161 uses a proprietary control scheme to save power and improve efficiency. The MP2161 will t ...
Impulse Voltage Generators 100 kV up to 1200 kV
... stages to maximum output voltages of 1150 kV (LI) and 900 kV (SI) in the no-load case. The generators can be modified for carrying out a variety of special tests, e.g. on transformers, impulse current testing of surge arresters as well as EMP tests of electrical equipment. The chosen modular system ...
... stages to maximum output voltages of 1150 kV (LI) and 900 kV (SI) in the no-load case. The generators can be modified for carrying out a variety of special tests, e.g. on transformers, impulse current testing of surge arresters as well as EMP tests of electrical equipment. The chosen modular system ...
LMC669 Auto-Zero - Elektronik
... Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating the device beyond its specified operating conditions. Note 2: All voltages are with respect to AGND. Note 3: This input current will exist onl ...
... Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating the device beyond its specified operating conditions. Note 2: All voltages are with respect to AGND. Note 3: This input current will exist onl ...
Voltage Rating
... Slash voltage rated OCPDs must be utilized only on solidly grounded systems. This automatically eliminates their usage on impedance-grounded and ungrounded systems. They can be properly utilized on solidly grounded, wye systems, where the voltage to ground does not exceed the device’s lower voltage ...
... Slash voltage rated OCPDs must be utilized only on solidly grounded systems. This automatically eliminates their usage on impedance-grounded and ungrounded systems. They can be properly utilized on solidly grounded, wye systems, where the voltage to ground does not exceed the device’s lower voltage ...
AMT – 101 General Aircraft Technology Drawings
... • Check for open diode bridge – Power on, engine at 1500 RPM and lights on – Check AC voltage on B lead • If over 0.5 V, bridge is bad – replace alternator ...
... • Check for open diode bridge – Power on, engine at 1500 RPM and lights on – Check AC voltage on B lead • If over 0.5 V, bridge is bad – replace alternator ...
2N3906
... system whose failure to perform can be reasonably expected to are intended for surgical implant into the body or (b) support or cause the failure of the life support device or system, or to affect its sustain life, and (c) whose failure to perform when properly used in safety or effectiveness. accor ...
... system whose failure to perform can be reasonably expected to are intended for surgical implant into the body or (b) support or cause the failure of the life support device or system, or to affect its sustain life, and (c) whose failure to perform when properly used in safety or effectiveness. accor ...
Solid core dipoles and switching power supplies: lower cost light
... stainless vacuum vessel. End plate (purple) and coil pocket plates (blue) set to 6E7. Software allowed induced currents to flow across material boundaries if the conductivities are equal, so this produces a shorted copper turn and is denoted CuTurn. Vacuum vessel set to stainless conductivity. (3) ...
... stainless vacuum vessel. End plate (purple) and coil pocket plates (blue) set to 6E7. Software allowed induced currents to flow across material boundaries if the conductivities are equal, so this produces a shorted copper turn and is denoted CuTurn. Vacuum vessel set to stainless conductivity. (3) ...
Effect of alternating current on electrolytic solutions
... f. Temperature sensitive solutions can not be electrolyzed. A.C has a definite frequency of 50-60Hz. When the voltage is stepped down the frequency is unaltered. The electrodes alter their polarity 50 times a second. The heavy ions can not follow such high frequency. So they can’t be discharged effe ...
... f. Temperature sensitive solutions can not be electrolyzed. A.C has a definite frequency of 50-60Hz. When the voltage is stepped down the frequency is unaltered. The electrodes alter their polarity 50 times a second. The heavy ions can not follow such high frequency. So they can’t be discharged effe ...
BDTIC
... In the 3rd generation CCM PFC controller, ICE3PCS01G has 14 pins with the best performance in efficiency and protections. This IC introduce a few new features such as -0.2V peak current limit, boost follower mode, 5V voltage regulator supply up to 5mA and IC can be disable using external signal. ICE ...
... In the 3rd generation CCM PFC controller, ICE3PCS01G has 14 pins with the best performance in efficiency and protections. This IC introduce a few new features such as -0.2V peak current limit, boost follower mode, 5V voltage regulator supply up to 5mA and IC can be disable using external signal. ICE ...
Using Digital Potentiometers in Adjustable Step-Down DC-DC
... Equation 4 is the result of substituting Equations 2 and 3 into Equation 1, then solving for VOUT and simplifying the expression. Equation 5, is Equation 4, assuming VFB for the MAX1776 is constant at its nominal value, 1.25V, and the DS3903 with 128 positions is used. The circuit shown in Figure 2 ...
... Equation 4 is the result of substituting Equations 2 and 3 into Equation 1, then solving for VOUT and simplifying the expression. Equation 5, is Equation 4, assuming VFB for the MAX1776 is constant at its nominal value, 1.25V, and the DS3903 with 128 positions is used. The circuit shown in Figure 2 ...
BFR380L3
... For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expect ...
... For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expect ...
EUP8092 1.5A Linear Li-Ion/Polymer Charger IC with Integrated FET and Charger Timer
... Li-Ion/Polymer battery charger IC designed for handheld devices. This charger is designed to work with various types of AC adapters or a USB port and capable of operating with an input voltage as low as 2.65V. The EUP8092 operates as a linear charger and charges the battery in three phases: trickle ...
... Li-Ion/Polymer battery charger IC designed for handheld devices. This charger is designed to work with various types of AC adapters or a USB port and capable of operating with an input voltage as low as 2.65V. The EUP8092 operates as a linear charger and charges the battery in three phases: trickle ...
High Voltage Power Supplies
... Make Precise Current Measurements Lower Than 1µA Use a sensitive Keithley measurement instrument, such as a Keithley SourceMeter® Source Measure Unit (SMU) instrument, to measure current drawn by the device under test (DUT) that is below the sensitivity of the Series 2290 Power Supplies. Keithley So ...
... Make Precise Current Measurements Lower Than 1µA Use a sensitive Keithley measurement instrument, such as a Keithley SourceMeter® Source Measure Unit (SMU) instrument, to measure current drawn by the device under test (DUT) that is below the sensitivity of the Series 2290 Power Supplies. Keithley So ...
Voltage Detector relay for transfer system and
... v Unbalanced voltage only: V0. b Relay backup position v A switch allows choice of normal or inverse position for each relay. It gives the relay position when power supply is down. b Time delay is configurable for each relay v On active position v On inactive position. b Thresholds are configurable ...
... v Unbalanced voltage only: V0. b Relay backup position v A switch allows choice of normal or inverse position for each relay. It gives the relay position when power supply is down. b Time delay is configurable for each relay v On active position v On inactive position. b Thresholds are configurable ...
Triode

A triode is an electronic amplifying vacuum tube (or valve in British English) consisting of three electrodes inside an evacuated glass envelope: a heated filament or cathode, a grid, and a plate (anode). Invented in 1906 by Lee De Forest by adding a grid to the Fleming valve, the triode was the first electronic amplification device and the ancestor of other types of vacuum tubes such as the tetrode and pentode. Its invention founded the electronics age, making possible amplified radio technology and long-distance telephony. Triodes were widely used in consumer electronics devices such as radios and televisions until the 1970s, when transistors replaced them. Today, their main remaining use is in high-power RF amplifiers in radio transmitters and industrial RF heating devices. The word is derived from the Greek τρίοδος, tríodos, from tri- (three) and hodós (road, way), originally meaning the place where three roads meet.