MN225014EN/ Old S225-10-10PSVR
... Eaton's pad-mounted voltage regulators are suitable for three- or four-wire underground systems. The 2-in-1 and 3-in-1 configurations consist of two or three single-phase voltage regulators in a single tank. A bypass module is available for the single-phase configuration only. Eaton voltage regulato ...
... Eaton's pad-mounted voltage regulators are suitable for three- or four-wire underground systems. The 2-in-1 and 3-in-1 configurations consist of two or three single-phase voltage regulators in a single tank. A bypass module is available for the single-phase configuration only. Eaton voltage regulato ...
Technical Article - Polymeric Insulators
... In the early 1960s, distribution class (CE) insulators were first sold commercially in the U.S. under the name GEPOL. These units failed due to surface damage and puncture. CE was used later in experimental 500 kV station breaker bushings, and in 115 kV bushings in the 1970s, and for suspension insu ...
... In the early 1960s, distribution class (CE) insulators were first sold commercially in the U.S. under the name GEPOL. These units failed due to surface damage and puncture. CE was used later in experimental 500 kV station breaker bushings, and in 115 kV bushings in the 1970s, and for suspension insu ...
Development of Modulation Strategies for NPC Inverter Addressing
... As well known the two-level topology generates CMV in the motor windings furthermore causing motor failures due to bearing currents. As there are parasitic capacitive couplings between the stator windings and the motor frame a common mode leakage current will flow, hence there will be common mode el ...
... As well known the two-level topology generates CMV in the motor windings furthermore causing motor failures due to bearing currents. As there are parasitic capacitive couplings between the stator windings and the motor frame a common mode leakage current will flow, hence there will be common mode el ...
Enabling Low-Distortion Varactors for Adaptive Transmitters , Student Member, IEEE , Fellow, IEEE
... widely used today for these challenging applications. However, these solutions are considered to be too expensive, or consume too much dc power, to be an acceptable long-term solution for cost and performance sensitive applications. This limitation has triggered an intensive search for alternatives ...
... widely used today for these challenging applications. However, these solutions are considered to be too expensive, or consume too much dc power, to be an acceptable long-term solution for cost and performance sensitive applications. This limitation has triggered an intensive search for alternatives ...
Loss of AC Voltage Considerations - pes-psrc
... directional sensing. For the 30° unit, maximum operating torque occurs when the current (op) flow from polarity to non-polarity of the current coil leads the voltage (VPOL) drop from polarity to non-polarity of the voltage coil by 30°. The 60 and 0 units are defined similarly. For all units, the ...
... directional sensing. For the 30° unit, maximum operating torque occurs when the current (op) flow from polarity to non-polarity of the current coil leads the voltage (VPOL) drop from polarity to non-polarity of the voltage coil by 30°. The 60 and 0 units are defined similarly. For all units, the ...
Old Company Name in Catalogs and Other Documents
... Notes: 1. Short circuit between the output and VCC will be a cause to destory the circuit. The maximum output current is about 20 mA for any supply voltage. 2. HA17903APS: These are the allowable values up to Ta = 55°C. Derate by 8.3mW/°C above that temperature. 3. HA17903AFP/ARP: These are the allo ...
... Notes: 1. Short circuit between the output and VCC will be a cause to destory the circuit. The maximum output current is about 20 mA for any supply voltage. 2. HA17903APS: These are the allowable values up to Ta = 55°C. Derate by 8.3mW/°C above that temperature. 3. HA17903AFP/ARP: These are the allo ...
- LJMU Research Online
... IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS particular, the current ripple and its peak-to-peak value are depicted, together with the instantaneous output voltage v(t). In ...
... IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS particular, the current ripple and its peak-to-peak value are depicted, together with the instantaneous output voltage v(t). In ...
Conext Core XC Series Grid Tie Photovoltaic Inverter: Operation
... The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety m ...
... The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety m ...
Modeling of electrodes and implantable pulse generator cases for
... Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (M ...
... Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (M ...
Integra Digital Metering System
... as a percentage of the energy count that would result from applying range maximum voltage and nominal current for the same measurement period. Error change due to variation of an influence quantity (except temperature) by varying one influence quantity within range of use, whilst keeping all other i ...
... as a percentage of the energy count that would result from applying range maximum voltage and nominal current for the same measurement period. Error change due to variation of an influence quantity (except temperature) by varying one influence quantity within range of use, whilst keeping all other i ...
Old Company Name in Catalogs and Other Documents
... confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website. Renesas Electronics does not assume any liability ...
... confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website. Renesas Electronics does not assume any liability ...
PV Inverter SUNNY BOY 6000TL‑US ⁄ 7000TL‑US
... distribution grid. This current is first supplied to the local loads (E). The surplus energy is fed into the power distribution grid (G). The amount of current required from the power distribution grid is reduced by the current supplied directly to the local loads. An energy surplus may even result ...
... distribution grid. This current is first supplied to the local loads (E). The surplus energy is fed into the power distribution grid (G). The amount of current required from the power distribution grid is reduced by the current supplied directly to the local loads. An energy surplus may even result ...
Table of Contents - UCF EECS - University of Central Florida
... The Transformer Monitoring System is defined as a group of components built together in order to sense and monitor various parameters of a pole-mounted transformer or ground transformer that are vital to its functionality. This device is attached to an existing transformer’s lines with minimal effor ...
... The Transformer Monitoring System is defined as a group of components built together in order to sense and monitor various parameters of a pole-mounted transformer or ground transformer that are vital to its functionality. This device is attached to an existing transformer’s lines with minimal effor ...
Solving High Performance Circuit Protection Needs in Space
... and space-restricted applications such as telecommunications and industrial communications equipment, surge protective devices and PCB assemblies. Flexible mounting options provide electronic designers with solutions that can help reduce the size of their equipment designs or increase the density of ...
... and space-restricted applications such as telecommunications and industrial communications equipment, surge protective devices and PCB assemblies. Flexible mounting options provide electronic designers with solutions that can help reduce the size of their equipment designs or increase the density of ...
MELF Resistors - Token Components
... The RFM speciality series of high frequency non-inductance MELF resistor from Token Electronics has been extended to offer more than GHz operation, making the devices more suitable for high frequency RF applications. They are the perfect choice in high frequency circuit designs where the parasitic i ...
... The RFM speciality series of high frequency non-inductance MELF resistor from Token Electronics has been extended to offer more than GHz operation, making the devices more suitable for high frequency RF applications. They are the perfect choice in high frequency circuit designs where the parasitic i ...
ZXTP03200BZ
... Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use ...
... Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use ...
Triode
A triode is an electronic amplifying vacuum tube (or valve in British English) consisting of three electrodes inside an evacuated glass envelope: a heated filament or cathode, a grid, and a plate (anode). Invented in 1906 by Lee De Forest by adding a grid to the Fleming valve, the triode was the first electronic amplification device and the ancestor of other types of vacuum tubes such as the tetrode and pentode. Its invention founded the electronics age, making possible amplified radio technology and long-distance telephony. Triodes were widely used in consumer electronics devices such as radios and televisions until the 1970s, when transistors replaced them. Today, their main remaining use is in high-power RF amplifiers in radio transmitters and industrial RF heating devices. The word is derived from the Greek τρίοδος, tríodos, from tri- (three) and hodós (road, way), originally meaning the place where three roads meet.