AVOP-ELEKTRO-HOL-001
... It means that each analog quantity can have in any interval indefinite number of values. The signal is due to the material imperfection and the external environment distorted or degraded during its processing. Most important thing is that the value isn’t changing rapidly and has a definitive value i ...
... It means that each analog quantity can have in any interval indefinite number of values. The signal is due to the material imperfection and the external environment distorted or degraded during its processing. Most important thing is that the value isn’t changing rapidly and has a definitive value i ...
Thevenin Equivalence
... The equivalent current source has value 8V/4k and the combined current source has value 4mA Options at this point 1. Do another source transformation and get a single loop circuit ...
... The equivalent current source has value 8V/4k and the combined current source has value 4mA Options at this point 1. Do another source transformation and get a single loop circuit ...
MAX16804 High-Voltage, 350mA LED Driver with Analog and PWM Dimming Control General Description
... Note 2: Resistors were added from OUT to CS+ to aid with the power dissipation during testing. Note 3: Dropout is measured as follows: Connect a resistor from OUT to CS+. Connect RSENSE = 0.56Ω from CS+ to CS-. Set VIN = VOUT +3V (record VOUT as VOUT1). Reduce VIN until VOUT = 0.97 x VOUT1 (record a ...
... Note 2: Resistors were added from OUT to CS+ to aid with the power dissipation during testing. Note 3: Dropout is measured as follows: Connect a resistor from OUT to CS+. Connect RSENSE = 0.56Ω from CS+ to CS-. Set VIN = VOUT +3V (record VOUT as VOUT1). Reduce VIN until VOUT = 0.97 x VOUT1 (record a ...
Selection Guide to Clamp-On Current Probes
... and remains electrically isolated from the meter input terminals. As a result, the meter’s low input terminal may be either floated or grounded. It is not necessary to interrupt the power supply when using a clamp-on current probe for taking measurements, so costly down time can be eliminated. True ...
... and remains electrically isolated from the meter input terminals. As a result, the meter’s low input terminal may be either floated or grounded. It is not necessary to interrupt the power supply when using a clamp-on current probe for taking measurements, so costly down time can be eliminated. True ...
HVACR Controls Sensors - Their Design and
... • By holding one junction at a known temperature (reference junction) and measuring the voltage, the temperature at the sensing junction can be deduced. • The voltage generated is directly proportional to the temperature difference. ...
... • By holding one junction at a known temperature (reference junction) and measuring the voltage, the temperature at the sensing junction can be deduced. • The voltage generated is directly proportional to the temperature difference. ...
Point-on-Wave Controller Developed for Circuit - Stoa Social
... They were incorporated to the analogical and digital interface plates kit that provides six inputs under voltage (0 to 130Vac) and six isolated current inputs (4 to 20ma) besides sixteen opto-digital inputs coupled dry contact type, and six digital voltage outputs implemented through IGBT's (Insulat ...
... They were incorporated to the analogical and digital interface plates kit that provides six inputs under voltage (0 to 130Vac) and six isolated current inputs (4 to 20ma) besides sixteen opto-digital inputs coupled dry contact type, and six digital voltage outputs implemented through IGBT's (Insulat ...
The Effect of Voltage Fluctuations on the Single Event Transient
... Lower VDD => Larger Time Constant => Slower Circuit => Longer Transients ...
... Lower VDD => Larger Time Constant => Slower Circuit => Longer Transients ...
Altech/ABL Sursum Miniature Circuit Breakers
... circuit breakers and MA motor protection switches for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang ...
... circuit breakers and MA motor protection switches for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang ...
MAX8631X,Y - Maxim Part Number Search
... up to 30mA per LED for backlighting. The flash group of LEDs (F1–F4) is independently controlled and can be driven up to 100mA per LED (or 400mA total). Two 200mA LDOs are on-board to provide power for camera functions. The LDOs’ output voltages are pin-programmable to meet different camera-module r ...
... up to 30mA per LED for backlighting. The flash group of LEDs (F1–F4) is independently controlled and can be driven up to 100mA per LED (or 400mA total). Two 200mA LDOs are on-board to provide power for camera functions. The LDOs’ output voltages are pin-programmable to meet different camera-module r ...
SWD-119-PIN Quad Driver for GaAs FET Switches and Attenuators Features
... Positive to negative Supply Range ...
... Positive to negative Supply Range ...
A1S64AD,A/D Converter module,HARDWARE
... z When wiring in the PLC, be sure that it is done correctly by checking the product's rated voltage and the terminal layout. Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or damage. z Tighten terminal screws to the specified torque ...
... z When wiring in the PLC, be sure that it is done correctly by checking the product's rated voltage and the terminal layout. Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or damage. z Tighten terminal screws to the specified torque ...
HGTG10N120BND 35A, 1200V, NPT Series N
... Operating frequency information for a typical device (Figure 3) is presented as a guide for estimating device performance for a specific application. Other typical frequency vs collector current (ICE) plots are possible using the information shown for a typical unit in Figures 5, 6, 7, 8, 9 and 11. ...
... Operating frequency information for a typical device (Figure 3) is presented as a guide for estimating device performance for a specific application. Other typical frequency vs collector current (ICE) plots are possible using the information shown for a typical unit in Figures 5, 6, 7, 8, 9 and 11. ...
LT1638/LT1639 - 1.2MHz, 0.4V/us Over-The-Top Micropower Rail-to-Rail Input and Output Op Amps
... The LT1638/LT1639 op amps operate on all single and split supplies with a total voltage of 2.5V to 44V drawing only 170μA of quiescent current per amplifier. These amplifiers are reverse battery protected and draw no current for reverse supply up to 18V. The input range of the LT1638/LT1639 includes b ...
... The LT1638/LT1639 op amps operate on all single and split supplies with a total voltage of 2.5V to 44V drawing only 170μA of quiescent current per amplifier. These amplifiers are reverse battery protected and draw no current for reverse supply up to 18V. The input range of the LT1638/LT1639 includes b ...
papers in PDF format
... Abstract--Load voltage control is an indispensable tack in electrical power distributed systems in the presence of nonlinear probabilities of load. Traditionally series compensators and voltage-source converter-based shunt are used for load voltage control. Deeper study into the load voltage control ...
... Abstract--Load voltage control is an indispensable tack in electrical power distributed systems in the presence of nonlinear probabilities of load. Traditionally series compensators and voltage-source converter-based shunt are used for load voltage control. Deeper study into the load voltage control ...
Exar 电源Blox 元器件订购手册
... wide input voltage range of 2.5V – 28V. • These parts offer the world’s only high current synchronous buck regulators with support for input voltages greater than 6V. • Offered in frequencies ranging from 300kHz to 1.3MHz, PowerBlox ICs support a wide variety of applications. ...
... wide input voltage range of 2.5V – 28V. • These parts offer the world’s only high current synchronous buck regulators with support for input voltages greater than 6V. • Offered in frequencies ranging from 300kHz to 1.3MHz, PowerBlox ICs support a wide variety of applications. ...
TPS61085T 数据资料 dataSheet 下载
... During the on-time, the voltage across the inductor causes the current in it to rise. When the current reaches a threshold value set by the internal GM amplifier, the power transistor is turned off, the energy stored into the inductor is then released and the current flows through the Schottky diode ...
... During the on-time, the voltage across the inductor causes the current in it to rise. When the current reaches a threshold value set by the internal GM amplifier, the power transistor is turned off, the energy stored into the inductor is then released and the current flows through the Schottky diode ...
MAX1534 High-Efficiency, Triple-Output, Keep-Alive Power Supply for Notebook Computers General Description
... Power Supply for Notebook Computers (Circuit of Figure 1, VIN = 12V, ILIM = GND, PRESET = GND, TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = ...
... Power Supply for Notebook Computers (Circuit of Figure 1, VIN = 12V, ILIM = GND, PRESET = GND, TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = ...
IGC39T65QE High Speed IGBT3 Chip
... approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support, automotive, aviation and aerospace device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended ...
... approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support, automotive, aviation and aerospace device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended ...
resonance analysis and soft-switching design of
... by the voltage doubler capacitor, clamping capacitor, and leakage inductance of coupled inductors, the reverse-recovery problem of the secondary diodes is restrained within the whole operation range. By choosing appropriate magnetic inductance of the coupled inductors, zerovoltage switching ON of th ...
... by the voltage doubler capacitor, clamping capacitor, and leakage inductance of coupled inductors, the reverse-recovery problem of the secondary diodes is restrained within the whole operation range. By choosing appropriate magnetic inductance of the coupled inductors, zerovoltage switching ON of th ...
voltage regulator and parallel operation
... current of the current transformer. Typical current transformers are designed for a 5 ampere secondary current with a 25VA maximum burden rating. Ohm’s Law (Voltage = Current X Resistance) will show the maximum voltage across the one ohm burden resistor to be 5 volts. It can then be seen that the re ...
... current of the current transformer. Typical current transformers are designed for a 5 ampere secondary current with a 25VA maximum burden rating. Ohm’s Law (Voltage = Current X Resistance) will show the maximum voltage across the one ohm burden resistor to be 5 volts. It can then be seen that the re ...
Chapter 13: Electric Circuits 1. A household circuit rated at 120 Volts
... 24. A 100 watt bulb is rated for use in a 120 volt line. During a brownout the actual voltage drops to 100 V. The actual power dissipated in the bulb under these conditions is A. 120 W. B. 100 W. C. 83.3 W. D. 69.4 W. E. 48.2 W. Answer: D 25. A heater is rated to dissipate 1800 W when connected to ...
... 24. A 100 watt bulb is rated for use in a 120 volt line. During a brownout the actual voltage drops to 100 V. The actual power dissipated in the bulb under these conditions is A. 120 W. B. 100 W. C. 83.3 W. D. 69.4 W. E. 48.2 W. Answer: D 25. A heater is rated to dissipate 1800 W when connected to ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.