MAX8863T/S/R, MAX8864T/S/R Low-Dropout, 120mA Linear Regulators __________________General Description
... range and deliver up to 120mA. A PMOS pass transistor allows the low, 80µA supply current to remain independent of load, making these devices ideal for battery-operated portable equipment such as cellular phones, cordless phones, and modems. ...
... range and deliver up to 120mA. A PMOS pass transistor allows the low, 80µA supply current to remain independent of load, making these devices ideal for battery-operated portable equipment such as cellular phones, cordless phones, and modems. ...
Power dissipation
... Unit Delay This hazard may be propagated through additional logic levels and result in multiple gate output transitions before the circuit resolves to a final state, even if the final state is unchanged from the previous state. Source: Jan M. Rabaey ...
... Unit Delay This hazard may be propagated through additional logic levels and result in multiple gate output transitions before the circuit resolves to a final state, even if the final state is unchanged from the previous state. Source: Jan M. Rabaey ...
AC/DC Current Probe Model SL206 Features
... The electronics and batteries are selfcontained in the handles. It is an excellent companion to DMMs, recorders and loggers, oscilloscopes and waveform displaying instruments. Low phase shift also insures reliable power and power quality measurements. The Model SL206 is very familiar with two mV ran ...
... The electronics and batteries are selfcontained in the handles. It is an excellent companion to DMMs, recorders and loggers, oscilloscopes and waveform displaying instruments. Low phase shift also insures reliable power and power quality measurements. The Model SL206 is very familiar with two mV ran ...
BP5033-12
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
... "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. ...
attachment=2411
... A switching surge is a short duration transient voltage produced in the system due to a sudden opening or closing of a switch or c.b or due to an arcing at a fault in the system. Impulse generator circuit is modified to give longer duration wave shape,100/1000 μs,R1 is increased to very high value a ...
... A switching surge is a short duration transient voltage produced in the system due to a sudden opening or closing of a switch or c.b or due to an arcing at a fault in the system. Impulse generator circuit is modified to give longer duration wave shape,100/1000 μs,R1 is increased to very high value a ...
Basler Electric AVC63-12 and AVC125
... the following procedure. Symptoms of startup problems stemming from improper regulator adjustments and certain generator system problems that resemble faulty regulation are listed with possible solutions. Simplifying the system by eliminating components, such as remote adjustment potentiometers and ...
... the following procedure. Symptoms of startup problems stemming from improper regulator adjustments and certain generator system problems that resemble faulty regulation are listed with possible solutions. Simplifying the system by eliminating components, such as remote adjustment potentiometers and ...
Example 1: 2-wire resistance measurements vs. 4
... For signal or waveform generation on a student lab bench, Keithley has paired the best-in-class performance of the Model 3390 Arbitrary Waveform/Function Generator with the best price in the industry to provide student labs with superior wave¬form generation functionality and flexibility at an unpar ...
... For signal or waveform generation on a student lab bench, Keithley has paired the best-in-class performance of the Model 3390 Arbitrary Waveform/Function Generator with the best price in the industry to provide student labs with superior wave¬form generation functionality and flexibility at an unpar ...
SERIES 10 PORTABLE MULTICHANNEL ANALYZER CANBERRA
... The rear panel carries the power switch and seven signal connectors. POWER SWITCH The power switch has six positions: 1RST, 2-3 STBY, 4-5 ON, and 6 HV ON. The STBY and ON positions are both doubled to provide some protection against accidentally moving the switch from ON to RST or from STBY to HV ON ...
... The rear panel carries the power switch and seven signal connectors. POWER SWITCH The power switch has six positions: 1RST, 2-3 STBY, 4-5 ON, and 6 HV ON. The STBY and ON positions are both doubled to provide some protection against accidentally moving the switch from ON to RST or from STBY to HV ON ...
STD830CP40
... The STD830CP40 is a hybrid complementary pair of power bipolar transistors manufactured by using the high voltage multi-epitaxial planar technology for high switching speeds and medium voltage capability. ...
... The STD830CP40 is a hybrid complementary pair of power bipolar transistors manufactured by using the high voltage multi-epitaxial planar technology for high switching speeds and medium voltage capability. ...
Target Datasheet
... 3A 380KHZ 32V PWM Buck DC/DC Converter Note1: Stresses greater than those listed under Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation is not implied. ...
... 3A 380KHZ 32V PWM Buck DC/DC Converter Note1: Stresses greater than those listed under Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation is not implied. ...
in Word Doc Format
... (B) lags behind the flux by 90 degree. (C) leads the flux by 90 degree. (D) is in phase opposition to that of flux. Ans: C Q.18 The relative speed between the magnetic fields of stator and rotor under steady state operation is zero for a (A) dc machine. (B) 3 phase induction machine. (C) synchronous ...
... (B) lags behind the flux by 90 degree. (C) leads the flux by 90 degree. (D) is in phase opposition to that of flux. Ans: C Q.18 The relative speed between the magnetic fields of stator and rotor under steady state operation is zero for a (A) dc machine. (B) 3 phase induction machine. (C) synchronous ...
Low Power Low Offset Voltage Single Comparator
... common-mode input voltage unless otherwise specified. ** The voltage at either input or common-mode should not be allowed to go negative by more than 0.3V. The upper end of the common-mode voltage range is VCC -1.5V, but either or both inputs can go to 30V without damage ...
... common-mode input voltage unless otherwise specified. ** The voltage at either input or common-mode should not be allowed to go negative by more than 0.3V. The upper end of the common-mode voltage range is VCC -1.5V, but either or both inputs can go to 30V without damage ...
RESISTORS FOR ENERGY METERING
... the clamping voltage of around 100µs duration (unless restricted by the series capacitor.) In this case most of the energy is absorbed by the MOV with the input resistor providing a secondary stage of ...
... the clamping voltage of around 100µs duration (unless restricted by the series capacitor.) In this case most of the energy is absorbed by the MOV with the input resistor providing a secondary stage of ...
Bipolar Transistor -12V -1A VCE(sat);-240mV(max.) PNP Single CPH3
... aerospace instrument, nuclear control device, burning appliances, transportation machine, traffic signal system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to h ...
... aerospace instrument, nuclear control device, burning appliances, transportation machine, traffic signal system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to h ...