Microwave Power Combiners
... •Gets rid of even harmonics can be used for very wide bandwidths (more than x2) in situations where filtering cannot be done •Push pull leads to more uniform current draw from supply, so grounding source is not a big problem ...
... •Gets rid of even harmonics can be used for very wide bandwidths (more than x2) in situations where filtering cannot be done •Push pull leads to more uniform current draw from supply, so grounding source is not a big problem ...
Sorensen XG 1500 Series 1500 W 6–600 V 2.6–187.5 A
... DC-waveforms through internal sequencing To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB. ...
... DC-waveforms through internal sequencing To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB. ...
NJW4191
... using a superior high-frequency characteristics ceramic capacitor for the output capacitor (C3). One of effective method to reduce noise is a ceramic capacitor and an electrolytic capacitor connect in parallel. Moreover, it is effective to use a low pass filter such as RC filter. In addition, the ri ...
... using a superior high-frequency characteristics ceramic capacitor for the output capacitor (C3). One of effective method to reduce noise is a ceramic capacitor and an electrolytic capacitor connect in parallel. Moreover, it is effective to use a low pass filter such as RC filter. In addition, the ri ...
LG30 / SMLG30 TO-8 Thin-Film Linearizer For The G30 Product Image
... combination of the LG30 and the G30 modules has a typical attenuation characteristic which is linear with control voltage provided the following conditions are met: 1. Positive supply = 15V ± 1% 2. Negative supply = -15V ± 1% 3. Source resistance of variable supply ≤1 Ω The LG30 has a response time ...
... combination of the LG30 and the G30 modules has a typical attenuation characteristic which is linear with control voltage provided the following conditions are met: 1. Positive supply = 15V ± 1% 2. Negative supply = -15V ± 1% 3. Source resistance of variable supply ≤1 Ω The LG30 has a response time ...
GT500 and GT500 MVX grid-tie solar inverters
... Designed for large scale applications, the GT500 and GT500 MVX is a high efficient, proven high reliability inverter suitable for both utility power plants and large rooftops. The GT500 connects directly to the low voltage grid using a high efficiency low voltage transformer supplied by Schneider El ...
... Designed for large scale applications, the GT500 and GT500 MVX is a high efficient, proven high reliability inverter suitable for both utility power plants and large rooftops. The GT500 connects directly to the low voltage grid using a high efficiency low voltage transformer supplied by Schneider El ...
Recapturing Lost Space from Mechanical/Thermal Restrictions
... power module products, offering an industry-leading 25% reduction in board space over previous and competing solutions. This innovation includes the utilization of the PMBus™ 4mm* interface for digital configuration, communication and control, as well as adaptive voltage scaling for power reduction. ...
... power module products, offering an industry-leading 25% reduction in board space over previous and competing solutions. This innovation includes the utilization of the PMBus™ 4mm* interface for digital configuration, communication and control, as well as adaptive voltage scaling for power reduction. ...
MX321 AUTOMATIC VOLTAGE REGULATOR (AVR)
... amount of short circuit current flowing during three phase and single phase short circuits on the generator output. Uncontrolled over excitation is limited to a safe period by internal shutdown of the AVR output device. This condition remains latched until the generator has been stopped. For complet ...
... amount of short circuit current flowing during three phase and single phase short circuits on the generator output. Uncontrolled over excitation is limited to a safe period by internal shutdown of the AVR output device. This condition remains latched until the generator has been stopped. For complet ...
Intro to Testing - Electrical and Computer Engineering Department
... • If each device is measured according to its specifications with the load and real input • Then; The sum of the parts will work. • Interaction with the other modules should be synchronize if needed. • Board Specs and electrical characteristics should be taken into consideration as load. ...
... • If each device is measured according to its specifications with the load and real input • Then; The sum of the parts will work. • Interaction with the other modules should be synchronize if needed. • Board Specs and electrical characteristics should be taken into consideration as load. ...
Ohm`s Law states that current is proportional to voltage
... Additional insight is gained by solving I=V/R for V, yielding V=IR. This expression for V can be interpreted as the voltage drop across a resistor produced by the flow of current I. The phrase IR drop is often used for this voltage. If voltage is measured at various points in a circuit, it will be s ...
... Additional insight is gained by solving I=V/R for V, yielding V=IR. This expression for V can be interpreted as the voltage drop across a resistor produced by the flow of current I. The phrase IR drop is often used for this voltage. If voltage is measured at various points in a circuit, it will be s ...
Full paper template_PEMD
... somewhat dependant on geometric shape, solar energy still need much more improvement in energy transformation and application efficiency. These energies are generating electrical energy in collective sites, and will result in high power loss during the transmission process. When they are malfunction ...
... somewhat dependant on geometric shape, solar energy still need much more improvement in energy transformation and application efficiency. These energies are generating electrical energy in collective sites, and will result in high power loss during the transmission process. When they are malfunction ...
P4500S Enclosed System Specifications
... A minimum of 2 pole fuse circuit must be provided between the battery terminal and the distribution bus. An open fuse/breaker/switch alarm with 1 form C contacts must be provided. For distributed loads up to 24 switchgears, provide an integrated DC panel within the battery charger compartment. The d ...
... A minimum of 2 pole fuse circuit must be provided between the battery terminal and the distribution bus. An open fuse/breaker/switch alarm with 1 form C contacts must be provided. For distributed loads up to 24 switchgears, provide an integrated DC panel within the battery charger compartment. The d ...
WEEK 3-4: DIRECT CURRENT GENERATOR
... • In DC series generators field winding is connected in series with armature and load. Hence, here load current is similar to field current. Thus, the loading characteristic curve is close to the machine magnetization curve. At no load, there is no field current, so VT is reduced to a small level gi ...
... • In DC series generators field winding is connected in series with armature and load. Hence, here load current is similar to field current. Thus, the loading characteristic curve is close to the machine magnetization curve. At no load, there is no field current, so VT is reduced to a small level gi ...
MD Series Spec - Controlled Power Company
... The system shall be designed and manufactured to assure maximum reliability, serviceability and performance. The system’s microprocessor, PWM inverter, highly filtered current and voltage regulated 2 stage battery charger and high speed transfer devices shall be provided on one single main PC board ...
... The system shall be designed and manufactured to assure maximum reliability, serviceability and performance. The system’s microprocessor, PWM inverter, highly filtered current and voltage regulated 2 stage battery charger and high speed transfer devices shall be provided on one single main PC board ...
THD Reduction in DVR by Firefly
... DVR is used to control injected voltage into transmission line to compensate faults whether sag or swell. For this purpose IGBT controlled by pulse width modulator is used. The pulse width of PWM can be controlled and for this purpose some controllers like PI, fuzzy logic and firefly optimised fuzzy ...
... DVR is used to control injected voltage into transmission line to compensate faults whether sag or swell. For this purpose IGBT controlled by pulse width modulator is used. The pulse width of PWM can be controlled and for this purpose some controllers like PI, fuzzy logic and firefly optimised fuzzy ...
NK2422032209
... Under voltages of various duration are known under different names. Short duration under voltages are called ―voltage sags‖ or ―voltage dips‖. Long duration under voltage is normally simply referred to as ―under voltage‖. Voltage sag is a reduction in the supply voltage magnitude followed by a volta ...
... Under voltages of various duration are known under different names. Short duration under voltages are called ―voltage sags‖ or ―voltage dips‖. Long duration under voltage is normally simply referred to as ―under voltage‖. Voltage sag is a reduction in the supply voltage magnitude followed by a volta ...
fast pulser for high-altitude ignition research
... capacitance of about 100 pF, giving a pulse energy of 37 mJ at 27 kV. • A fast pulse risetime produces a higher voltage before the gas breaks down, coupling more energy into the discharge. For this design the risetime was specified to be less than 25 ns. • Finally, the pulser should be able to opera ...
... capacitance of about 100 pF, giving a pulse energy of 37 mJ at 27 kV. • A fast pulse risetime produces a higher voltage before the gas breaks down, coupling more energy into the discharge. For this design the risetime was specified to be less than 25 ns. • Finally, the pulser should be able to opera ...