
2004/05 Power Supply Design Seminar Book
... It should come as no surprise that safety is an important issue in the design of any electrical equipment which is liable to come into contact with a human operator or servicing individual. And this issue should be even more obvious when the equipment is designed to operate from a source of power wh ...
... It should come as no surprise that safety is an important issue in the design of any electrical equipment which is liable to come into contact with a human operator or servicing individual. And this issue should be even more obvious when the equipment is designed to operate from a source of power wh ...
CHAPTER 3: BASIC OF APPLIED MECHANICAL MEASUREMENT
... correct dimension and provides the required, consistent feel that ensures a repeatable measurement. The lower caliper in the image has an adjusting screw that permits it to be carefully adjusted without removal of the tool from the workpiece. ...
... correct dimension and provides the required, consistent feel that ensures a repeatable measurement. The lower caliper in the image has an adjusting screw that permits it to be carefully adjusted without removal of the tool from the workpiece. ...
Industrial Current/Voltage Output Driver with Programmable Ranges AD5748
... ranges: 4 mA to 21 mA and 0 mA to 21 mA. Voltage output is provided from a separate pin that can be configured to provide 0 V to 5 V, 0 V to 10.5 V, or ±10.5 V output range. Analog outputs are short-circuit and open-circuit protected and can drive capacitive loads of 2 μF and inductive loads of 0.1 ...
... ranges: 4 mA to 21 mA and 0 mA to 21 mA. Voltage output is provided from a separate pin that can be configured to provide 0 V to 5 V, 0 V to 10.5 V, or ±10.5 V output range. Analog outputs are short-circuit and open-circuit protected and can drive capacitive loads of 2 μF and inductive loads of 0.1 ...
KEP Master Spec
... 10.10. A time based load control feature shall be available to allow the prioritized addition and removal of loads based during transfer. This feature may be enabled for either or both sources. The user shall be able to control up to nine loads with independent timing sequences for pre and post tran ...
... 10.10. A time based load control feature shall be available to allow the prioritized addition and removal of loads based during transfer. This feature may be enabled for either or both sources. The user shall be able to control up to nine loads with independent timing sequences for pre and post tran ...
Fundamentals and Improvements for Directional Relays
... Zero-sequence, current-polarized directional elements use the neutral current from a local power transformer with a grounded neutral as the polarizing quantity. The operate quantity is the protected line ground current. Maximum torque develops when these two currents are in phase. Care is required t ...
... Zero-sequence, current-polarized directional elements use the neutral current from a local power transformer with a grounded neutral as the polarizing quantity. The operate quantity is the protected line ground current. Maximum torque develops when these two currents are in phase. Care is required t ...
IMS Mini Meter MMU Installation Guide
... 2. Technical Specifications .............................................................................................. 6 ...
... 2. Technical Specifications .............................................................................................. 6 ...
Energy minimization for reliability-guaranteed real-time
... recovery [2]. Task re-execution and checkpointing are two common techniques used for backward fault recovery. With these techniques, when a fault occurs, the computation is repeated from the most recent checkpoint, rather than from its beginning. However, taking a checkpoint also takes time and cons ...
... recovery [2]. Task re-execution and checkpointing are two common techniques used for backward fault recovery. With these techniques, when a fault occurs, the computation is repeated from the most recent checkpoint, rather than from its beginning. However, taking a checkpoint also takes time and cons ...
AN29 - Some Thoughts on DC-DC Converters
... memory, disc drives, display and operating logic. In theory, AC line powered systems should not need DC/DC converters because the implied power transformer can be equipped with multiple secondaries. In practice, economics, noise requirements, supply bus distribution problems and other constraints of ...
... memory, disc drives, display and operating logic. In theory, AC line powered systems should not need DC/DC converters because the implied power transformer can be equipped with multiple secondaries. In practice, economics, noise requirements, supply bus distribution problems and other constraints of ...
CYB_STS_1600A-4000A_Guideform Spec
... operation of the DSTS except to cause a transfer due to overvoltage beyond pre-set limits. Over-current Protection: The non-automatic internal breakers shall be rated at a continuous [1600] [2000] [3000] [4000] AF/NA current rating (frame rating should be higher if the breaker is derated 80%), wit ...
... operation of the DSTS except to cause a transfer due to overvoltage beyond pre-set limits. Over-current Protection: The non-automatic internal breakers shall be rated at a continuous [1600] [2000] [3000] [4000] AF/NA current rating (frame rating should be higher if the breaker is derated 80%), wit ...
MAX220–MAX249
... FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended fo ...
... FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended fo ...
MX15 Series AC and DC Power Source User Manual
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
MX15 Series AC and DC Power Source User Manual
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
Full-Text PDF
... applications. The proposed converter topology is designed for unidirectional power transfer and provides a doable solution for photovoltaic applications where voltage is required to be stepped up without magnetic components (transformer-less and inductor-less). The output voltage obtained from renew ...
... applications. The proposed converter topology is designed for unidirectional power transfer and provides a doable solution for photovoltaic applications where voltage is required to be stepped up without magnetic components (transformer-less and inductor-less). The output voltage obtained from renew ...
Haptic Drive with Auto Resonance Detection for Linear Resonance
... Linear Resonant Actuators, or LRAs, only vibrate effectively at their resonant frequency. LRAs have a high-Q frequency response due to which there is a rapid drop in vibration performance at offsets of 2 to 3 Hz from the resonant frequency. Many factors also cause a shift or drift in the resonant fr ...
... Linear Resonant Actuators, or LRAs, only vibrate effectively at their resonant frequency. LRAs have a high-Q frequency response due to which there is a rapid drop in vibration performance at offsets of 2 to 3 Hz from the resonant frequency. Many factors also cause a shift or drift in the resonant fr ...
Tech Brief 1 MicroLAN Design Guide
... the network. However, the 800 pF parasitic power supply capacitance only exists at voltage levels above 2.8V minimum. Ignoring the capacitance of the parasitic power capacitor, the bus pull-up resistor value, together with the cable capacitance and 1Wire device input capacitance represent the networ ...
... the network. However, the 800 pF parasitic power supply capacitance only exists at voltage levels above 2.8V minimum. Ignoring the capacitance of the parasitic power capacitor, the bus pull-up resistor value, together with the cable capacitance and 1Wire device input capacitance represent the networ ...
DETERMINING TRANSMISSION LINE PARAMETERS FROM TIME-STAMPED DATA by Martin Grobler
... en strome. Die term ’lyn parameters’ verwys na die inherente weerstand en induktansie wat in serie met mekaar voorkom op ’n transmissie lyn. ...
... en strome. Die term ’lyn parameters’ verwys na die inherente weerstand en induktansie wat in serie met mekaar voorkom op ’n transmissie lyn. ...
BDTIC www.BDTIC.com/infineon H a r d C o m m...
... The modest advancement in the development of trench field-plate power MOSFETs in the last decades has allowed more and more applications and systems to benefit from the advantage of fast switching and high power density. The breakdown voltage has evolved from sub 20V to 250V for state-of-the-art tre ...
... The modest advancement in the development of trench field-plate power MOSFETs in the last decades has allowed more and more applications and systems to benefit from the advantage of fast switching and high power density. The breakdown voltage has evolved from sub 20V to 250V for state-of-the-art tre ...
DMN53D0LW Product Summary Features
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...