• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Improved PWM inverter control system is based on the voltage type control method and the PWM power type control method. The result of simulation and conclusions shows that the improved PWM inverter control method can make the voltage and the current waveform of the grid tend to sine wave effectively ...
Powering the MSP430 from a High Voltage Input using the TPS62122
Powering the MSP430 from a High Voltage Input using the TPS62122

... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
Assessment to Study of Voltage Unbalance Effects about Efficiency
Assessment to Study of Voltage Unbalance Effects about Efficiency

... derating in the machine [4],[5], temperature rise, and life reduction [6], increase of losses, and negative effects on the insulation [4],[6] y [7] are some contributions in the area. In recent papers, [1], [2] and [4], the authors have concluded that the efficiency and power factor of the motor dep ...
P4 Datasheet - Hawker Electronics
P4 Datasheet - Hawker Electronics

... tight electrodes are available for side entry if required. A low voltage A.C. signal is used on the electrodes to prevent electrolysis. ...
to this file: /twr8-11w
to this file: /twr8-11w

... Max. rated temp., 1,000 hours 10 cycles, –55 to +125°C +85°C, 85% humidity, 48 hours Murata Power Solutions in-house procedure +70°C, 500 hours* Murata Power Solutions in-house procedure ...
Service Tips from the Pros
Service Tips from the Pros

... switch and requires power to activate/close the contacts – i.e., a 120V DC powered coil is responsible for making this occur. Have you ever heard a “humming noise” resonating from your ATS – the source is the coil... and the frequency/pitch of the noise will vary with the voltage at the coil. Enemie ...
High Voltage Nanosecond Pulse Measurement Techniques
High Voltage Nanosecond Pulse Measurement Techniques

... This voltage divider has been constructed with 5 x 110 Ω resistors in series for a total resistance of ~550 Ω. Therefore, clipping across a single resistor gives a voltage division ratio of 1:5. The total resistance and voltage division ratio have been labeled, as well as “All =” which indicates tha ...
Power MOSFET 100 Amps, 100 Volts
Power MOSFET 100 Amps, 100 Volts

G59 Application for connection of generation plant to distribution
G59 Application for connection of generation plant to distribution

... If the generation is to be operated at existing premises please confirm the MPAN number below: ...
BD8179MUV
BD8179MUV

... sufficient margin so that these two values are within the standard value range. (3) Selecting the Input Capacitor Since the peak current flows between the input and output at the DC/DC converter, a capacitor is required to install at the input side. For the reason, the low ESR capacitor is recommend ...
Preventing Component Circuit Damage from Above Range Current
Preventing Component Circuit Damage from Above Range Current

... Multifuse® products that now incorporate a new space-saving freeXpansion™ manufacturing process. From the inside out, Multifuse® devices are specifically designed to shield a wide range of applications against the potentially destructive effects of these conditions and provide exceptional protection ...
Operational Amplifiers
Operational Amplifiers

permanent magnet synchronous motor
permanent magnet synchronous motor

...  Projecting type  Inset type 2.Interioror Buried-PMSM ...
Comparative Study of Wind Energy Conversion System Driven by
Comparative Study of Wind Energy Conversion System Driven by

... of components, the matrix converter (MC) can be used for a direct AC/AC conversion without dc-link connection [1317]. The MC is widely employed in large wind farms that have many advantages: direct power converter AC/AC, bidirectional power flow, nearly sinusoidal input and output waveform, and allo ...
synchronous balanced operation of open
synchronous balanced operation of open

... been applied to basic topologies of cascaded converters consisting of two standard two-level voltage source inverters [4]-[7]. Almost all versions of conventional space-vector PWM are based on the asynchronous principle, which results in sub-harmonics (of the fundamental frequency) in the spectrum o ...
Conference Paper - UCF EECS - University of Central Florida
Conference Paper - UCF EECS - University of Central Florida

... Silicon-based MOSFETs and particularly CMOS can function better at low temperatures as opposed to bipolar transistors. For low temperatures, enhancement mode CMOS integrated circuits are used because they are expected to give the best overall performance in high speed/high density electronic systems ...
Measurement of standby power and energy efficiency
Measurement of standby power and energy efficiency

MAX5048 Maxim (reluctantly), fast FET driver.pdf
MAX5048 Maxim (reluctantly), fast FET driver.pdf

... pin can approach 1.3A, while at the GND pin the peak current can approach 7.6A. V CC drops and ground shifts are forms of negative feedback for inverters and, if excessive, can cause multiple switching when the INinput is used and the input slew rate is low. The device driving the input should be re ...
Fast Flashover Identification Methodology on Brushed DC
Fast Flashover Identification Methodology on Brushed DC

... conditions, by sparks and flashovers. Those problems may arise from mechanical issues, such as vibration, or electrical factors, such as overload, insulation issues, reverse polarity of the poles and rapid change of load. The brush sparking can also occur after a maintenance period, if interpole win ...
EPC9047 Quick Start Guide - Efficient Power Conversion
EPC9047 Quick Start Guide - Efficient Power Conversion

... simplify the evaluation process of these eGaN FETs by including all the critical components on a single board that can be easily connected into any existing converter. The development board is 2” x 1.5” and contains two eGaN FETs in a half bridge configuration using the Texas Instruments UCC27611 ga ...
permanent magnet synchronous motor
permanent magnet synchronous motor

F42033342
F42033342

EMI2121 数据资料DataSheet下载
EMI2121 数据资料DataSheet下载

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
LM 7805 VOLTAGE REGULATOR
LM 7805 VOLTAGE REGULATOR

MIL EMI and Transient Solutions
MIL EMI and Transient Solutions

< 1 ... 449 450 451 452 453 454 455 456 457 ... 717 >

Distribution management system

In the recent years, utilization of electrical energy increased exponentially and customer requirement and quality definitions of power were changed enormously. As the electric energy became an essential part of the daily life, its optimal usage and reliability became important. Real-time network view and dynamic decisions have become instrumental for optimizing resources and managing demands, thus making a distribution management system which could handle proper work flows, very critical.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report