• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CH26 LAB Capacitors
CH26 LAB Capacitors

... plates which are thin sheets of metal separated by a dielectric, insulating material. For this reason, the schematic symbol of a capacitor is has two vertical lines a small distance apart (representing the capacitor plates) connected to two lines representing the connecting wires (or leads). ...
INA1x8 High-Side Measurement Current Shunt
INA1x8 High-Side Measurement Current Shunt

... In Figure 9 the value chosen for the shunt resistor depends on the application and is a compromise between small-signal accuracy and maximum permissible voltage loss in the measurement line. High values of shunt resistor provide better accuracy at lower currents by minimizing the effects of offset, ...
Application Note 181 3-Terminal Regulator is Adjustable
Application Note 181 3-Terminal Regulator is Adjustable

... voltage while R1 provides the 5 mA programming current. The 2 capacitors on the adjustment and output terminals are optional for improved performance. Bypassing the adjustment terminal to ground improves ripple rejection. This bypass capacitor prevents ripple from being amplified as the output volta ...
PGA103 数据资料 dataSheet 下载
PGA103 数据资料 dataSheet 下载

... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
PSS15S92F6-AG
PSS15S92F6-AG

... It is recommended to insert a Zener diode D1(24V/1W) between each pair of control supply terminals to prevent surge destruction. To prevent surge destruction, the wiring between the smoothing capacitor and the P, N1 terminals should be as short as possible. Generally a 0.1-0.22μF snubber capacitor C ...
MATLAB Simulation for Speed Control of Three Phase Induction
MATLAB Simulation for Speed Control of Three Phase Induction

... Low cost, high efficiency, high robustness, reliability and low maintenance are some the advantages of the induction motors over DC motors. When mechanical loads are changed the speed characteristics for induction motor also changes. The induction motors do not have the constant speed characteristic ...
Chapter 4: Direct-Current Generators ()
Chapter 4: Direct-Current Generators ()

... • This voltage appears between the brushes, and therefore across the load • The voltage is maximum when the coil is in its horizontal position • The induced voltage is minimum when the coil is in its vertical position • The coil polarity changes every time the coil makes half a turn ...
FAN103 Primary-Side-Regulation PWM Controller (PWM-PSR) FAN103 — Primary-S ide-Regulat
FAN103 Primary-Side-Regulation PWM Controller (PWM-PSR) FAN103 — Primary-S ide-Regulat

... proprietary green-mode function provides off-time modulation to linearly decrease PWM frequency under light-load conditions. This green mode assists the power supply in meeting the power conservation requirement. By using the FAN103, a charger can be implemented with few external components and mini ...
Calibration Techniques for Precision Power - Techni-Tool
Calibration Techniques for Precision Power - Techni-Tool

... Corporate Phone: 610-825-4990 • Sales: 800-832-4866 or 610-941-2400 Fax: 800-854-8665 or 610-828-5623 • Web: www.techni-tool.com ...
Marine Electrical Knowledge
Marine Electrical Knowledge

... partialy interupted. Causes of open circuit faults are bad connections or a break in the wire. Open circuit faults when intermittent can cause flashes. Open circuit faults when not completely open (bad connection) can cause a lot of heat and are a fire hazzard. Open circuits in three phase circuits ...
S. Lim, J. Ranson, D.M. Otten, and D.J. Perreault, “Two-Stage Power Conversion Architecture for an LED Driver Circuit,” 2013 IEEE Applied Power Electronics Conference , pp. 854-861, March 2013.
S. Lim, J. Ranson, D.M. Otten, and D.J. Perreault, “Two-Stage Power Conversion Architecture for an LED Driver Circuit,” 2013 IEEE Applied Power Electronics Conference , pp. 854-861, March 2013.

... The system architecture we adopt targets LED driver circuits operating at low-to-moderate power levels and wide-ranging, grid-scale input voltages. We introduce circuit implementations and controls suitable for power levels of up to a few tens of watts, wide-range input voltages of up to 200 V (e.g. ...
1.1 TMACS/mW Load-Balanced Resonant Charge
1.1 TMACS/mW Load-Balanced Resonant Charge

... Despite dramatic improvements in energy efficiency, today’s solid-state circuit computing technology still operates far from fundamental kT /bit energy limits. In this paper we combine adiabatic CMOS circuit approaches with stochastic encoding techniques to achieve record-level energy efficiency in ...
STGW20NC60VD
STGW20NC60VD

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... So a new IBC, which is suitable for the applications where the input voltage is high and the operating duty is below 50%, is proposed. It is similar to the conventional IBC, The two active switches are driven with the phase shift angle of 180◦ and the output voltage is regulated by adjusting the dut ...
Direct Torque Control of Induction Machine Using Matrix Converter
Direct Torque Control of Induction Machine Using Matrix Converter

Shaker Flashlight - University of Michigan SharePoint Portal
Shaker Flashlight - University of Michigan SharePoint Portal

... Figure 5: Measuring the voltage of the AC circuit The signal is green, and we see that the voltage is alternating between positive and negative as a sine wave. It spends half the time positive, and half the time negative. This means that the current flows in one direction, slows down, flows in the ...
Tips for connecting 24-volt power
Tips for connecting 24-volt power

... problems or controller failure. Voltage drop occurs when power flows along a length of wire. To minimize the effects of voltage drop, connect transformers as close to their connected controllers as possible. The size of the connected load and the gauge of the connecting wire has a significant effect ...
IEEE Jackson PES Meeting
IEEE Jackson PES Meeting

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

MTL MA15 Surge Protectors Manual PDF
MTL MA15 Surge Protectors Manual PDF

... The maximum rating of equipment protected by the surge protection device. Examples: For an in-line surge protection device with maximum specified through or line current of 15A, a. Connected to a 30A power supply - Protect with 15A maximum. b. Connected to a 8.5A UPS or standby generator - Protect a ...
True Power vs. Apparent Power - Associated Power Technologies
True Power vs. Apparent Power - Associated Power Technologies

FPD750 0.5W POWER pHEMT Features Product Description
FPD750 0.5W POWER pHEMT Features Product Description

... These devices should be treated as Class 0 (0V to 250V) using the human body model as defined in JEDEC Standard No. 22A114. Further information on ESD control measures can be found in MIL-STD-1686 and MIL-HDBK-263. This is an unpackaged part and therefore no MSL rating applies. ...
NSS30100LT1G
NSS30100LT1G

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
RA60H4452M1 数据资料DataSheet下载
RA60H4452M1 数据资料DataSheet下载

Optimal output filter design for microprocessor
Optimal output filter design for microprocessor

... One can see that the first spike curves, N1 (dashed), do not have an extreme value and increase rapidly at low output inductance. The second spike curves, N2 (solid), have minimum value at some output inductance. In most cases the curves N1 cross the curves N2 at two points. The lowest-integer numbe ...
< 1 ... 428 429 430 431 432 433 434 435 436 ... 717 >

Distribution management system

In the recent years, utilization of electrical energy increased exponentially and customer requirement and quality definitions of power were changed enormously. As the electric energy became an essential part of the daily life, its optimal usage and reliability became important. Real-time network view and dynamic decisions have become instrumental for optimizing resources and managing demands, thus making a distribution management system which could handle proper work flows, very critical.