AN2454
... driver and the new STC04IE170 ESBT as main switch. It is associated with the release of the STEVAL-IPB001V1 demo board (see figure below). The design is a complete solution for the 2 W single output SMPS, which is widely used as a power supply in breaker applications. However, the design method can ...
... driver and the new STC04IE170 ESBT as main switch. It is associated with the release of the STEVAL-IPB001V1 demo board (see figure below). The design is a complete solution for the 2 W single output SMPS, which is widely used as a power supply in breaker applications. However, the design method can ...
SG6742WMR Highly Integrated Green-Mode PWM Controller
... SG6742WMR integrates a frequency-hopping function that helps reduce EMI emission of a power supply with minimum line filters. The built-in synchronized slope compensation achieves stable peak-current-mode control. The proprietary internal line compensation ensures constant output power limit over a ...
... SG6742WMR integrates a frequency-hopping function that helps reduce EMI emission of a power supply with minimum line filters. The built-in synchronized slope compensation achieves stable peak-current-mode control. The proprietary internal line compensation ensures constant output power limit over a ...
measurements of ac magnitude
... What is more, the back-and-forth motion of any two jigsaws may not be of the same type, depending on the mechanical design of the saws. One jigsaw might move its blade with a sine-wave motion, while another with a triangle-wave motion. To rate a jigsaw based on its peak blade speed would be quite mi ...
... What is more, the back-and-forth motion of any two jigsaws may not be of the same type, depending on the mechanical design of the saws. One jigsaw might move its blade with a sine-wave motion, while another with a triangle-wave motion. To rate a jigsaw based on its peak blade speed would be quite mi ...
H6-type transformerless single-phase inverter for grid
... a full-bridge inverter. Two extended HERIC topologies are proposed in [16, 27]. Although these topologies can achieve high efficiency and low leakage current, they have not yet been analysed from the point of view of reactive power handling capacity. In this study, a new transformerless grid-tied PV ...
... a full-bridge inverter. Two extended HERIC topologies are proposed in [16, 27]. Although these topologies can achieve high efficiency and low leakage current, they have not yet been analysed from the point of view of reactive power handling capacity. In this study, a new transformerless grid-tied PV ...
MAX5932EVKIT
... function compatible with the LT1641-1. This EV kit can be used to evaluate either part. The EV kit provides a power-good output signal that indicates the status of the output voltage. The MAX5932 EV kit is configured for a 48V input application and up to 4.7A of output current. Power for the circuit ...
... function compatible with the LT1641-1. This EV kit can be used to evaluate either part. The EV kit provides a power-good output signal that indicates the status of the output voltage. The MAX5932 EV kit is configured for a 48V input application and up to 4.7A of output current. Power for the circuit ...
Three-Dimensional Integrated Circuits
... • We have demonstrated several design methodologies to enhance power and signal integrity in 3D ICs ...
... • We have demonstrated several design methodologies to enhance power and signal integrity in 3D ICs ...
AP7313 - Diodes Incorporated
... factor of only 12.5 percent, enabling power savings by putting much of the baseband circuitry into standby mode in between transmit cycles. In baseband circuits, the load often transitions virtually instantaneously from 100µA to 100mA. To meet this load requirement, the LDO must react very quickly w ...
... factor of only 12.5 percent, enabling power savings by putting much of the baseband circuitry into standby mode in between transmit cycles. In baseband circuits, the load often transitions virtually instantaneously from 100µA to 100mA. To meet this load requirement, the LDO must react very quickly w ...
A Solid State Opening Switch and Mod Anode Supply for the
... in the left panel of Figure 3. This switch is also used as a modulator, like most of the high-power opening switches built by DTI. It has been operating at CPI since 1998. A deliberate arc is shown in the right panel of Figure 3. ...
... in the left panel of Figure 3. This switch is also used as a modulator, like most of the high-power opening switches built by DTI. It has been operating at CPI since 1998. A deliberate arc is shown in the right panel of Figure 3. ...
UM1016
... the operation of the relay. The voltage sensor needs a +/-15 V supply voltage which is provided by means of a multi-wire cable running from J5 on the power supply board to the 3way screw terminal connector, called VDC, on the output sensing board. The +15 V is also used to obtain the +5 V supplying ...
... the operation of the relay. The voltage sensor needs a +/-15 V supply voltage which is provided by means of a multi-wire cable running from J5 on the power supply board to the 3way screw terminal connector, called VDC, on the output sensing board. The +15 V is also used to obtain the +5 V supplying ...
MAX750A/MAX758A Adjustable, Step-Down, Current-Mode PWM Regulators _______________General Description
... 750mA, while the MAX750A accepts inputs from 4V to 11V and delivers 450mA. Typical efficiencies are 85% to 90%. Typical quiescent current is 1.7mA, or only 6µA in shutdown mode. The output does not exhibit any ripple at subharmonics of the switching frequency over its specified range. Pulse-width-mo ...
... 750mA, while the MAX750A accepts inputs from 4V to 11V and delivers 450mA. Typical efficiencies are 85% to 90%. Typical quiescent current is 1.7mA, or only 6µA in shutdown mode. The output does not exhibit any ripple at subharmonics of the switching frequency over its specified range. Pulse-width-mo ...
LP38512-ADJ - Texas Instruments
... A ceramic input capacitor of at least 10 µF is required. For general usage across all load currents and operating conditions, a 10 µF ceramic input capacitor will provide satisfactory performance. Output Capacitor A ceramic capacitor with a minimum value of 10 µF is required at the output pin for lo ...
... A ceramic input capacitor of at least 10 µF is required. For general usage across all load currents and operating conditions, a 10 µF ceramic input capacitor will provide satisfactory performance. Output Capacitor A ceramic capacitor with a minimum value of 10 µF is required at the output pin for lo ...
TPS51117 Single Synchronous Step-Down
... controller is dedicated for the operation of the Adaptive On-Time D-CAP mode. This mode provides ease-of-use, low external component count, and fast transient response. Auto-skip mode for high efficiency down to the milliampere load range, or PWM-only mode for low-noise operation is selectable. ...
... controller is dedicated for the operation of the Adaptive On-Time D-CAP mode. This mode provides ease-of-use, low external component count, and fast transient response. Auto-skip mode for high efficiency down to the milliampere load range, or PWM-only mode for low-noise operation is selectable. ...
Schneider Altivar ATV12 Quick Start Guide
... - Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc. - If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive • Install and close all covers befo ...
... - Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc. - If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive • Install and close all covers befo ...
RS-485 for Digital Motor Control Applications
... example, RS-232 or RS-422 signaling may be adequate in some applications—sometimes controller area network (CAN) or EtherNet/IP (Industrial Protocol) are preferred due to compatibility with an existing network. For higher speed applications, and where long distance and common-mode voltages are not a ...
... example, RS-232 or RS-422 signaling may be adequate in some applications—sometimes controller area network (CAN) or EtherNet/IP (Industrial Protocol) are preferred due to compatibility with an existing network. For higher speed applications, and where long distance and common-mode voltages are not a ...