• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Reliability and Failure Analysis of Electronic Components
Reliability and Failure Analysis of Electronic Components

... common failure modes of capacitors, followed by open failures. One common example of capacitor failures includes overvoltage or aging of the dielectric, occurring when breakdown voltage falls below operating voltage. • In addition to the problems listed above, electrolytic capacitors suffer from fai ...
Chapter 11 Constant Voltage Transformer (CVT)
Chapter 11 Constant Voltage Transformer (CVT)

... Electrical Parameters of a CVT Line Regulator When the constant voltage transformer is operating as a line regulator, the output voltage will vary as a function of the input voltage, as shown in Figure 11-3. The magnetic material used to design transformer, Tl, has an impact on line regulation. Tra ...
DRV11873 12-V, 3-Phase Sensorless BLDC Motor Controller (Rev. A)
DRV11873 12-V, 3-Phase Sensorless BLDC Motor Controller (Rev. A)

... DRV11873 is a three-phase, sensorless motor driver with integrated power MOSFETs with drive current capability up to 1.5-A continuous and 2-A peak. It is specifically designed for fan motor drive applications with low noise and low external component count. DRV11873 has built-in overcurrent protecti ...
SiC Schottky Diode in Power Factor Correction
SiC Schottky Diode in Power Factor Correction

... Efficiency gains alternatively can be used to allow the delivery of higher power from the same design. Efficiency improvements also may allow the design of a cooler running power system. Cooler operation leads to improvements in system reliability. As you can see, it really is all about the efficien ...
AN-395: Interfacing the AD22100 Temperature Sensor to a Low Cost Single-Chip Microcontroller
AN-395: Interfacing the AD22100 Temperature Sensor to a Low Cost Single-Chip Microcontroller

PCB Layout Design Considerations - Overall
PCB Layout Design Considerations - Overall

WT210/WT230 Digital Power Meters
WT210/WT230 Digital Power Meters

Transformer Basics Information Guide
Transformer Basics Information Guide

... Primary: Overload protection or Circuit Breaker (CB) is always required. It may be sized no less than 100% of the current draw on the primary and no more than 125%, unless there is overload protection on the secondary. If such is the case, the primary CB may be increased up to 250%. For Example: If ...
12A - Synqor
12A - Synqor

... connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is ...
High Voltage Direct Current Transmission –
High Voltage Direct Current Transmission –

... For a long cable connection, e.g. beyond 40 km, HVDC will in most cases offer the only technical solution because of the high charging current of an AC cable. This is of particular interest for transmission across open sea or into large cities where a DC cable may provide the only possible solution. ...
Film Capacitors - Power Factor Correction - MKP440-D-15
Film Capacitors - Power Factor Correction - MKP440-D-15

... statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check ...
Technical Paper - Edge - Rochester Institute of Technology
Technical Paper - Edge - Rochester Institute of Technology

NCP5006 Compact Backlight LED Boost Driver
NCP5006 Compact Backlight LED Boost Driver

... than the Over Voltage Protection threshold (OVP) the device comes back to shutdown mode. To restart the chip, one must either send a Low to High sequence on Pin EN, or switch off the Vbat supply. A capacitor must be used on the output voltage to avoid false triggering of the OVP circuit. This capaci ...
D.C. GENERATOR
D.C. GENERATOR

GSW WATER SOURCE HEAT PUMP SPECIFICATIONS
GSW WATER SOURCE HEAT PUMP SPECIFICATIONS

... reversing valve when cooling is demanded for the first time. The reversing valve shall be held in this position until the first call for heating, ensuring quiet operation and increased valve life.). c. Ability to work with heat pump or heat/cool (Y, W) type controls. d. Ability to work with controls ...
Sunmaster XS4300/ XS3200/ XS2000
Sunmaster XS4300/ XS3200/ XS2000

Narrowband Powerline Communication - Renesas e
Narrowband Powerline Communication - Renesas e

Start of pump systems
Start of pump systems

... The load of a centrifugal pump is suitable for start with reduced voltage. There is normally no initial load when the pump is started and the load will increase proportionally to the square of the speed. The basic idea when starting a pump with some kind of starting method is to reduce the motor tor ...
MAX1722/MAX1723/ MAX1724 1.5µA I , Step-Up DC-DC Converters in TSOT
MAX1722/MAX1723/ MAX1724 1.5µA I , Step-Up DC-DC Converters in TSOT

... Inductor Selection The control scheme of the MAX1722/MAX1723/ MAX1724 permits flexibility in choosing an inductor. A 10µH inductor value performs well in most applications. Smaller inductance values typically offer smaller physical size for a given series resistance, allowing the smallest overall ci ...
Stability Analysis of Single Machine Infinite Bus Power System
Stability Analysis of Single Machine Infinite Bus Power System

... Conventional TCSC is used in existing power system stabilizers is contribution in enhancing power system dynamic stability. The parameters of TCSC are determined based on linearized model of the power system around a nominal operating point where they can provide good performance. Since power system ...
ST-70 Base Line Testing
ST-70 Base Line Testing

... down to the best small lot used car salesman's tactics: Trust me! With so many modification options, and so many new folks arriving at the doorstep of our hobby daily, the plan of attack in restoring these units can be bewildering to say the least. I own a rather pristine, early model example of thi ...
Reduced wiring system (CC-Link compliant SI unit) EX140
Reduced wiring system (CC-Link compliant SI unit) EX140

... Operation at a range that exceeds the specifications can cause a fire, malfunction, or damage to the unit. Verify the specifications before use. ♦Do not use the product in an atmosphere containing combustible, explosive or corrosive gas. It can cause a fire, explosion or corrosion. The unit is not d ...
White Paper on
White Paper on

... If redundant I/O modules are desired to achieve availability and maintainability, then several methods utilizing terminations are possible. Each method and associated terminations offer various degrees of diagnostics, ease of use and costs. The levels discussed in this paper are based on the followi ...
Designing a Control System for High Availability
Designing a Control System for High Availability

... If redundant I/O modules are desired to achieve availability and maintainability, then several methods utilizing terminations are possible. Each method and associated terminations offer various degrees of diagnostics, ease of use and costs. The levels discussed in this paper are based on the followi ...
PAM2320 Description Pin Assignments
PAM2320 Description Pin Assignments

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
< 1 ... 273 274 275 276 277 278 279 280 281 ... 717 >

Distribution management system

In the recent years, utilization of electrical energy increased exponentially and customer requirement and quality definitions of power were changed enormously. As the electric energy became an essential part of the daily life, its optimal usage and reliability became important. Real-time network view and dynamic decisions have become instrumental for optimizing resources and managing demands, thus making a distribution management system which could handle proper work flows, very critical.