• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TA3020 STEREO 300W (4Ω) CLASS-T DIGITAL AUDIO AMPLIFIER
TA3020 STEREO 300W (4Ω) CLASS-T DIGITAL AUDIO AMPLIFIER

... voltage Protection section in the Application Information for a detailed discussion of the internal circuit operation and external component selection. Main overvoltage and undervoltage sense resistor for the positive supply (VPP). Please refer to the Electrical Characteristics Section for the trip ...
INFLUENCE OF A SOLAR MODULE`S FILL FACTOR ON THE
INFLUENCE OF A SOLAR MODULE`S FILL FACTOR ON THE

... parameters for a c-Si model with a fill factor of 72%. Alternatively, parameters for a thin film model with a fill factor of 57.6% are provided. As mentioned under section 1, a fill factor of 72% is not representative for modern c-Si modules. Also, a fill factor of 57.6% is too low for many thin fil ...
MAX3386E 3.0V, ±25kV ESD-Protected RS-232 Transceiver for PDAs and Cell Phones General Description
MAX3386E 3.0V, ±25kV ESD-Protected RS-232 Transceiver for PDAs and Cell Phones General Description

... is a communications interface with low power requirements, high data-rate capabilities, and enhanced electrostatic discharge (ESD) protection. The MAX3386E has two receivers and three transmitters. All RS-232 inputs and outputs are protected to ±25kV using the IEC 1000-4-2 Air-Gap Discharge method, ...
modelling of electric field distribution for partial discharges in air
modelling of electric field distribution for partial discharges in air

... overhead line conductors, assuming the electric field strength on their surface has sufficient value for the impact ionization and development of electron avalanches. Initial corona field strength is typically determined from an empirical Peek formula [3], which takes into account the radius of the ...
A METHOD FOR CHARACTERIZATION OF THREE
A METHOD FOR CHARACTERIZATION OF THREE

... recommendations. The method is based on the well-proven theory of symmetrical components. The primary result of the method is a so-called "characteristic magnitude" which corresponds to the magnitude (remaining voltage) as used for the existing methods to characterize dips experienced by single-phas ...
AAT4672 数据资料DataSheet下载
AAT4672 数据资料DataSheet下载

... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
RF5385 2.4GHz TO 2.5GHz, 802.11b/g/n WiFi FRONT END MODULE Features
RF5385 2.4GHz TO 2.5GHz, 802.11b/g/n WiFi FRONT END MODULE Features

... Product Description The RF5385 provides an integrated front-end solution for WiFi 802.11b/g/n and Bluetooth® systems. The ultra small form factor package and integrated matching greatly reduces the number of external components and layout area in the customer application. This simplifies the total F ...
Precision, 20MHz, 0.9pA, Low-Noise, RRIO, CMOS Op Amp with
Precision, 20MHz, 0.9pA, Low-Noise, RRIO, CMOS Op Amp with

... SBOS513E – AUGUST 2010 – REVISED JUNE 2013 ...
PDF
PDF

... converter. Therefore, the cost of implementation a matrix converter is larger than a conventional dc-link converter of the similar ratings. Finally, the amplitude of the output voltages generated by a matrix converter is narrow to 0.866 of the input voltage amplitude for the most standard modulation ...
March 2009 - How to Choose a Voltage Reference
March 2009 - How to Choose a Voltage Reference

... the supply voltage and load current do not vary much. If either, or both, may change substantially, then the resistor must be chosen to accommodate this variance, often forcing the circuit to dissipate significantly more power than required for the nominal case. It can be considered to function like ...
G. Hassan, D.J. Perreault, and T.A. Keim, “Design of Dual-Output Alternators with Switched-Mode Rectification,” IEEE Transactions on Power Electronics , Vol. 20, No. 1, Jan. 2005, pp. 164-172.
G. Hassan, D.J. Perreault, and T.A. Keim, “Design of Dual-Output Alternators with Switched-Mode Rectification,” IEEE Transactions on Power Electronics , Vol. 20, No. 1, Jan. 2005, pp. 164-172.

... the normalized number of stator winding turns for a conventional 120-A 14-V alternator geometry. (The winding normalization is such that 1 represents the number of turns on a conventional 120-A 14-V alternator design.) It can be seen that at idle speed, there is no remarkable change in the output cu ...
Basic Circuit Elements
Basic Circuit Elements

... Now, we will have circuit components, which are physical items, whose behavior is very much like the behavior of combinations of the elements we are going to describe. We will model these circuit components with our circuit elements. The mindset you want to develop though, should be clear; we are ap ...
AP7311
AP7311

... Fast transient response LDOs can extend battery life. TDMA-based cell phone protocols such as Global System for Mobile Communications (GSM) have a transmit/receive duty factor of only 12.5 percent, enabling power savings by putting much of the baseband circuitry into standby mode in between transmit ...
Methods for detecting ground faults in medium-voltage
Methods for detecting ground faults in medium-voltage

... Without timely correction, these faults can be hazardous to human lives and property. There have been a number of documented cases of costly litigation as a result of damages from undetected downed power conductors. HIFs on multigrounded distribution systems are difficult to detect at the substation ...
Complete PDF Edition (762 KB)
Complete PDF Edition (762 KB)

... the manufacturing technologies available in 1978, an element life of 1 ~ 2 years was considered acceptable. Lower protection levels also require arrestors to absorb the energy of switching surges associated with circuit breaker activity and power-frequency temporary overvoltage (TOV) associated with ...
16230 Emergency Generator
16230 Emergency Generator

... field, with amortisseur windings, with direct drive centrifugal blower for proper cooling and minimum noise, with temperature compensated solid-state voltage regulator, with brushless rotating rectifier exciter system. Brushes will not be allowed. Generator shall be directly connected to engine flyw ...
Power MOSFET Basics
Power MOSFET Basics

... A control device is subjected to a double pulse. The current ramps in the lower control device, and freewheels through the DUT body diode when the control device turns off. When it is turned on again by the second pulse, the DUT body diode must recover before the control FET voltage can drop. During ...
2.5A - SynQor
2.5A - SynQor

... connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is ...
Dynamic Characteristics of Mho Distance Relays
Dynamic Characteristics of Mho Distance Relays

... condition than it does steady-state, and it does not operate under either dynamic or steady-state conditions. (2) Load Flow in Tripping Direction Fig. 16 shows the effect of load flow in the tripping direction, using the same system conditions as in Fig. 10. Consider the R1 relay and the F4 fault l ...
Battery Cell Identification and SOC Estimation Using String Terminal Voltage Measurements
Battery Cell Identification and SOC Estimation Using String Terminal Voltage Measurements

... state of health (SOH), failure status, and life-expectancy prediction [2]–[6]. To accomplish this, existing approaches require individual cell’s voltage and current data for internal state estimation and system identification [7]–[9], with high costs for sensors and packaging, and substantial reliab ...
NRD1-6_Rev.0110 - pes-psrc
NRD1-6_Rev.0110 - pes-psrc

... identified by the amount of difference between the currents entering the bus and those exiting the bus. (PC37.234) [6059] Differential current. The sum of all currents entering and leaving a section of the electrical system; measured with consistent polarity. Also referred to as an operating current ...
A Generalized Form of Tellegen`s Theorem
A Generalized Form of Tellegen`s Theorem

DH34667671
DH34667671

Aalborg Universitet
Aalborg Universitet

... continuously updating and becoming more stringent. In addition, the demands on various power level and costumer needs are extending. These bring the absolute interest of having a flexible system which can be adapted with varied situation as it can reduce the cost of the system significantly. This pa ...
LM2675 SIMPLE SWITCHER Power Converter High Efficiency 1A Step-Down Voltage Regulator
LM2675 SIMPLE SWITCHER Power Converter High Efficiency 1A Step-Down Voltage Regulator

... 260 kHz, thus allowing smaller sized filter components than what would be needed with lower frequency switching regulators. Because of its very high efficiency ( > 90%), the copper traces on the printed circuit board are the only heat sinking needed. A family of standard inductors for use with the L ...
< 1 ... 271 272 273 274 275 276 277 278 279 ... 717 >

Distribution management system

In the recent years, utilization of electrical energy increased exponentially and customer requirement and quality definitions of power were changed enormously. As the electric energy became an essential part of the daily life, its optimal usage and reliability became important. Real-time network view and dynamic decisions have become instrumental for optimizing resources and managing demands, thus making a distribution management system which could handle proper work flows, very critical.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report