MAX1692 Low-Noise, 5.5V-Input, PWM Step-Down Regulator General Description
... The device operates in one of four modes. Forced PWM mode operates at a fixed frequency regardless of the load. Synchronizable PWM mode allows an external switching frequency to control and minimize harmonics. Idle Mode™ (PWM/PFM) extends battery life by switching to a PFM pulse-skipping mode during ...
... The device operates in one of four modes. Forced PWM mode operates at a fixed frequency regardless of the load. Synchronizable PWM mode allows an external switching frequency to control and minimize harmonics. Idle Mode™ (PWM/PFM) extends battery life by switching to a PFM pulse-skipping mode during ...
full text pdf
... a single topology makes it challenging to understand all important circuit selection and operation aspects. The challenge does not disappear even if advanced numerical circuit simulations are deployed – simulation is not a substitute for sufficient understanding of this advanced circuit. The topolog ...
... a single topology makes it challenging to understand all important circuit selection and operation aspects. The challenge does not disappear even if advanced numerical circuit simulations are deployed – simulation is not a substitute for sufficient understanding of this advanced circuit. The topolog ...
PE4251
... Ground Connection. Traces should be physically short and connected to ground plane for best performance. ...
... Ground Connection. Traces should be physically short and connected to ground plane for best performance. ...
Guide to Motor Caravan Distributed Intelligence System
... The distributors are nodes through which the energy leading from the batteries is distributed via the Power-Links. The distributors subdivide the energy on the various loads connected to them extremely safely and they limit it to prevent hazards in the event of a short circuit. For this purpose non- ...
... The distributors are nodes through which the energy leading from the batteries is distributed via the Power-Links. The distributors subdivide the energy on the various loads connected to them extremely safely and they limit it to prevent hazards in the event of a short circuit. For this purpose non- ...
Qucs - A Tutorial
... As mentionned earlier, a particular attention will be placed on the DC study, since the overall current consumtion is a crucial point, and the noise factor that we could have. ...
... As mentionned earlier, a particular attention will be placed on the DC study, since the overall current consumtion is a crucial point, and the noise factor that we could have. ...
SFH655A - Vishay
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
MAX8732A/3A/4A DS - Maxim Integrated
... Continuous Power Dissipation (TA = +70°C) 28-Pin QSOP (derate 10.8mW/°C above +70°C).........860mW Operating Temperature Range ...........................-40°C to +85°C Junction Temperature ......................................................+150°C Storage Temperature Range ....................... ...
... Continuous Power Dissipation (TA = +70°C) 28-Pin QSOP (derate 10.8mW/°C above +70°C).........860mW Operating Temperature Range ...........................-40°C to +85°C Junction Temperature ......................................................+150°C Storage Temperature Range ....................... ...
General Description Features
... The MAX16833/MAX16833B–MAX16833D are peak current-mode-controlled LED drivers for boost, buckboost, SEPIC, flyback, and high-side buck topologies. A dimming driver designed to drive an external p-channel in series with the LED string provides wide-range dimming control. This feature provides extreme ...
... The MAX16833/MAX16833B–MAX16833D are peak current-mode-controlled LED drivers for boost, buckboost, SEPIC, flyback, and high-side buck topologies. A dimming driver designed to drive an external p-channel in series with the LED string provides wide-range dimming control. This feature provides extreme ...
Controls Training Course
... Select proper locations for the installation of electronic controls systems. Identify and describe the various types of wire and cable used for electronic control systems. Describe the proper way to install and terminate control wiring. List common sources of ”noise” and explain how to corre ...
... Select proper locations for the installation of electronic controls systems. Identify and describe the various types of wire and cable used for electronic control systems. Describe the proper way to install and terminate control wiring. List common sources of ”noise” and explain how to corre ...
cdv/dt induced turn-on in synchronous buck regulators
... is not to reduce the Cdv/dt induced voltage, but is instead intended to pull down the turn-off gate voltage at Q2 to below zero. This will shift the Cdv/dt induced voltage to below the threshold voltage. The corresponding waveforms after implementing the AC gate drive are demonstrated in Figure 10. ...
... is not to reduce the Cdv/dt induced voltage, but is instead intended to pull down the turn-off gate voltage at Q2 to below zero. This will shift the Cdv/dt induced voltage to below the threshold voltage. The corresponding waveforms after implementing the AC gate drive are demonstrated in Figure 10. ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.6, pp. 1917-1924
... Un-fortunately, these rectifiers drew non sinusoidal currents from the utility and led to harmonic pollution on the grid. To regulate these problems and maintain power quality, some recommended standards [2], [3], which listed the acceptable distortion levels for different utilities, were published ...
... Un-fortunately, these rectifiers drew non sinusoidal currents from the utility and led to harmonic pollution on the grid. To regulate these problems and maintain power quality, some recommended standards [2], [3], which listed the acceptable distortion levels for different utilities, were published ...
Battery Charge Regulator (BCR)
... as criterion for operation. As well as modern control procedure (for example: state of charge algorithm). The following standard govern the requirement of BCR, which is installed permanently in photovoltaic system, especially for small domestic power supply (Solar Home Systems, SHS). with system vol ...
... as criterion for operation. As well as modern control procedure (for example: state of charge algorithm). The following standard govern the requirement of BCR, which is installed permanently in photovoltaic system, especially for small domestic power supply (Solar Home Systems, SHS). with system vol ...
PLD Application Guide - Portable PA
... Loudspeaker power capacities............................................................................................................................................................................................................20 Application: Stereo passive tops and subs........................ ...
... Loudspeaker power capacities............................................................................................................................................................................................................20 Application: Stereo passive tops and subs........................ ...
High Frequency Induction Welding
... Mandrels • Used to treat inside weld bead shape or scarfing • Nonmagnetic Material like Austenitic SS (Impeders also needed) ...
... Mandrels • Used to treat inside weld bead shape or scarfing • Nonmagnetic Material like Austenitic SS (Impeders also needed) ...
138000 Volt Instrument Transformers
... rated for use on 138,000 volt systems with 650kV BIL. The unit is a station service voltage transformer with power and can be supplied with metering rated secondary winding(s). It provides a convenient and cost effective means of serving small power and/ or metering requirements directly from a tran ...
... rated for use on 138,000 volt systems with 650kV BIL. The unit is a station service voltage transformer with power and can be supplied with metering rated secondary winding(s). It provides a convenient and cost effective means of serving small power and/ or metering requirements directly from a tran ...
Megger PULSAR Equipment Specifications
... LINE SYNCHRONIZATION: PULSAR was designed to be completely independent of the line voltage and frequency. However, there may be applications where synchronizing to the line frequency may be desirable. With Line Synchronization activated, the output voltages and currents will be in phase with the inp ...
... LINE SYNCHRONIZATION: PULSAR was designed to be completely independent of the line voltage and frequency. However, there may be applications where synchronizing to the line frequency may be desirable. With Line Synchronization activated, the output voltages and currents will be in phase with the inp ...
CMOS Device Model
... 3.1-4 (Also, use google scholar to find one or two well cited papers on symmetric models of MOSFET, and quickly study them.) ...
... 3.1-4 (Also, use google scholar to find one or two well cited papers on symmetric models of MOSFET, and quickly study them.) ...