BDTIC I S O F A C E
... The IC contains 2 galvanic isolated voltage domains that are independent from each other. The input interface is supplied at VCC and the output stage is supplied at Vbb. The different voltage domains can be switched on at different time. The output stage is only enabled once the input stage enters a ...
... The IC contains 2 galvanic isolated voltage domains that are independent from each other. The input interface is supplied at VCC and the output stage is supplied at Vbb. The different voltage domains can be switched on at different time. The output stage is only enabled once the input stage enters a ...
BDTIC www.BDTIC.com/infineon ® Version 2.1a, 11 Jan 2012
... CoolSET®-F3R 650V version (ICE3BRxx65J). It is particular good for high voltage margin low power SMPS application such as auxiliary power supply for PC and server. The major characteristics are that the IC is developed with 800V CoolMOS® with start up cell, having adjustable brownout feature, runnin ...
... CoolSET®-F3R 650V version (ICE3BRxx65J). It is particular good for high voltage margin low power SMPS application such as auxiliary power supply for PC and server. The major characteristics are that the IC is developed with 800V CoolMOS® with start up cell, having adjustable brownout feature, runnin ...
ADR525 数据手册DataSheet 下载
... references, housed in ultrasmall SC70 and SOT-23-3 packages. These references feature low temperature drift of 40 ppm/°C, an initial accuracy of better than ±0.2%, and ultralow output noise of 14 μV p-p. Available in output voltages of 2.048 V, 2.5 V, 3.0 V, 4.096 V, and 5.0 V, the advanced design o ...
... references, housed in ultrasmall SC70 and SOT-23-3 packages. These references feature low temperature drift of 40 ppm/°C, an initial accuracy of better than ±0.2%, and ultralow output noise of 14 μV p-p. Available in output voltages of 2.048 V, 2.5 V, 3.0 V, 4.096 V, and 5.0 V, the advanced design o ...
Calculating AC Line Voltage Drop for S230
... the microinverter is located at the array, and the point of common coupling (PCC) is generally at the site load center, the distance from the microinverter AC output to the PCC could be substantial. All components within system wiring contribute to resistance and must be considered when calculating ...
... the microinverter is located at the array, and the point of common coupling (PCC) is generally at the site load center, the distance from the microinverter AC output to the PCC could be substantial. All components within system wiring contribute to resistance and must be considered when calculating ...
Design Optimization of High Frequency Transformer for Dual
... leakage inductance and the phase-shifted angle between its terminal square wave voltages. As a result, there is always a trade-off between the leakage inductance and the phaseshifted angle when maximizing the power conversion. Additionally, at high switching frequency, high AC losses in the HFT wind ...
... leakage inductance and the phase-shifted angle between its terminal square wave voltages. As a result, there is always a trade-off between the leakage inductance and the phaseshifted angle when maximizing the power conversion. Additionally, at high switching frequency, high AC losses in the HFT wind ...
Issues to Consider when Substituting Large Power Transformers in
... of UT (rated voltages, rated MVA, impedance, and over-excitation) by portraying graphically their effect under various operation conditions. While this method is mainly dedicated to a new plant project, it may be also used in case of a substitute transformer. A typical graph (Fig. 2) shows the chang ...
... of UT (rated voltages, rated MVA, impedance, and over-excitation) by portraying graphically their effect under various operation conditions. While this method is mainly dedicated to a new plant project, it may be also used in case of a substitute transformer. A typical graph (Fig. 2) shows the chang ...
a battery energy storage system based on a multilevel cascade pwm
... B. Transformerless System A transformer-based system seems more practical at present. Nevertheless, a transformerless system may also be viable in the next 5-10 years, in which the cascade number and the dc-link voltage would be higher than those in the transformer-based system. Their optimization w ...
... B. Transformerless System A transformer-based system seems more practical at present. Nevertheless, a transformerless system may also be viable in the next 5-10 years, in which the cascade number and the dc-link voltage would be higher than those in the transformer-based system. Their optimization w ...
LIGHTNING IMPULSE TESTS ON AIR
... work using FEMM simulation. The air breakdown voltages between the electrodes (point and plane) are measured by conducting the air breakdown voltage experiment in high voltage laboratory and corresponding electrical field strength. The electrodes gap distances are being varied to 5 different gaps wh ...
... work using FEMM simulation. The air breakdown voltages between the electrodes (point and plane) are measured by conducting the air breakdown voltage experiment in high voltage laboratory and corresponding electrical field strength. The electrodes gap distances are being varied to 5 different gaps wh ...
chapter 2 switched reluctance motor and its application
... below rated speed. Base speed (ωb) is defined as the highest speed at which maximum current can be supplied to the motor (Imax) at rated voltage, with fixed switching angles. There is, of course, a family of characteristics for varying supply voltages. At a given speed the flux is proportional to th ...
... below rated speed. Base speed (ωb) is defined as the highest speed at which maximum current can be supplied to the motor (Imax) at rated voltage, with fixed switching angles. There is, of course, a family of characteristics for varying supply voltages. At a given speed the flux is proportional to th ...
Model 2290 10 kV Power Supply
... Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. T ...
... Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. T ...
MAX17582 Dual-Phase, Quick-PWM Controller for IMVP-6.5 CPU Core Power Supplies General Description
... VCC, VDD, V3P3 to GND ...........................................-0.3V to +6V D0–D6 to GND..........................................................-0.3V to +6V PGDIN, DPRSLPVR, PSI to GND..............................-0.3V to +6V SLOW to GND ......................................................... ...
... VCC, VDD, V3P3 to GND ...........................................-0.3V to +6V D0–D6 to GND..........................................................-0.3V to +6V PGDIN, DPRSLPVR, PSI to GND..............................-0.3V to +6V SLOW to GND ......................................................... ...
Schneider Telemechanique Altivar 71 Installation Manual (0.37kW
... capacitors will be reduced. • If it is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. It is recommended that the drive is not connected directly to the line voltage. The voltage should be ...
... capacitors will be reduced. • If it is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. It is recommended that the drive is not connected directly to the line voltage. The voltage should be ...
Evaluates: MAX1407/MAX1408/MAX1409/MAX1414 MAX1407 Evaluation Kit/Evaluation System General Description Features
... the Start menu. The program automatically downloads KIT1407.c32 to the module. Once the download has successfully completed, the main application window appears. To ensure that the system is working properly, select the Clock control panel and press Synchronize with PC button. The MAX1407 real-time ...
... the Start menu. The program automatically downloads KIT1407.c32 to the module. Once the download has successfully completed, the main application window appears. To ensure that the system is working properly, select the Clock control panel and press Synchronize with PC button. The MAX1407 real-time ...
Klystrons
... transition pieces. This is in contrast to the tests at DESY, Orsay and KEK where a complete pair of couplers must be tested. On this bench one can determine the gas load from the “device under test” and evaluate which parts of the coupler are contributing to multipactor or long conditioning. They pl ...
... transition pieces. This is in contrast to the tests at DESY, Orsay and KEK where a complete pair of couplers must be tested. On this bench one can determine the gas load from the “device under test” and evaluate which parts of the coupler are contributing to multipactor or long conditioning. They pl ...
AN109 - Interfacing RF I/Q Modulators with Popular D/A Converters
... output noise level of the modulator at this frequency, due to the noise of the LT1565-31, is then 84.2nV/√Hz. Given an RF system impedance of 50Ω, this is 45.5dB above kTB, or –128.5dBm/Hz. Note, however, that this elevation of noise level occurs only within the passband of the active filter. So the ...
... output noise level of the modulator at this frequency, due to the noise of the LT1565-31, is then 84.2nV/√Hz. Given an RF system impedance of 50Ω, this is 45.5dB above kTB, or –128.5dBm/Hz. Note, however, that this elevation of noise level occurs only within the passband of the active filter. So the ...
BDTIC
... out of band compression. Another problem occurs when the FM transmitter is sending signals. The power amplifiers output signal levels can be up to 10 dBm. In a 50Ohm environment this wouldn’t be an issue but in mobile handsets it is. The FM transmitter must not use an external antenna instead it has ...
... out of band compression. Another problem occurs when the FM transmitter is sending signals. The power amplifiers output signal levels can be up to 10 dBm. In a 50Ohm environment this wouldn’t be an issue but in mobile handsets it is. The FM transmitter must not use an external antenna instead it has ...
S2000C
... • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels • Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling ...
... • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels • Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling ...
LVDT SELECTION, HANDLING AND INSTALLATION GUIDELINES APPLICATION NOTE Preamble
... possible, and/or the use of low-capacitance cables is strongly recommended. For DC LVDTs it is a different matter. The length of the cable affects the amount of noise superimposed onto the DC output voltage and generated by the EMI (Electro-Magnetic Interference) waves, function of the electromagnet ...
... possible, and/or the use of low-capacitance cables is strongly recommended. For DC LVDTs it is a different matter. The length of the cable affects the amount of noise superimposed onto the DC output voltage and generated by the EMI (Electro-Magnetic Interference) waves, function of the electromagnet ...
.3Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS
... relay settings meet these requirements. Suncor needs at least 2 years to meet this Standard to do the following: ...
... relay settings meet these requirements. Suncor needs at least 2 years to meet this Standard to do the following: ...
Skyworks Capacitor Model for ESD Applications
... New York, USA, three models are based on where the charge is stored, including human body model (HBM), machine model (MM), and charged device model (CDM) [3]. In the handset industry, HBM is considered the most important model and employed by most production ESD tests as well as in this paper. The c ...
... New York, USA, three models are based on where the charge is stored, including human body model (HBM), machine model (MM), and charged device model (CDM) [3]. In the handset industry, HBM is considered the most important model and employed by most production ESD tests as well as in this paper. The c ...
LM2576 3.0 A, 15 V, Step−Down Switching Regulator
... components to simplify the power supply design. Standard series of inductors optimized for use with the LM2576 are offered by several different inductor manufacturers. Since the LM2576 converter is a switch−mode power supply, its efficiency is significantly higher in comparison with popular three−te ...
... components to simplify the power supply design. Standard series of inductors optimized for use with the LM2576 are offered by several different inductor manufacturers. Since the LM2576 converter is a switch−mode power supply, its efficiency is significantly higher in comparison with popular three−te ...