PWM, Step-Down DC-to-DC Controller with Margining and Tracking ADP1822
... PWM, Step-Down DC-to-DC Controller with Margining and Tracking ADP1822 The ADP1822 regulated output can track another power supply and can be dynamically adjusted up or down with the controller’s margining-control inputs, making it ideal for high reliability applications. It is well suited for a wid ...
... PWM, Step-Down DC-to-DC Controller with Margining and Tracking ADP1822 The ADP1822 regulated output can track another power supply and can be dynamically adjusted up or down with the controller’s margining-control inputs, making it ideal for high reliability applications. It is well suited for a wid ...
Difference Amplifier Forms Heart of Precision
... 3 Detecting Human Falls with a 3-Axis Digital Accelerometer 1 0 Measuring Noise of Low-Fixed-Gain Differential Amplifiers 1 1 The Basics of Video Decoders in Supervision and Inspection 1 4 How to Apply Low-Dropout Regulators Successfully ...
... 3 Detecting Human Falls with a 3-Axis Digital Accelerometer 1 0 Measuring Noise of Low-Fixed-Gain Differential Amplifiers 1 1 The Basics of Video Decoders in Supervision and Inspection 1 4 How to Apply Low-Dropout Regulators Successfully ...
MAX5974A Evaluation Kit Evaluates: General Description Features
... The EV kit is a galvanically isolated 25W DC-DC converter using the active-clamped, current-mode PWM controller in a forward, coupled-inductor feedback topology. The EV kit receives power from an IEEE 802.3af/at-compliant PSE and a UTP cable connected to the EV kit’s RJ45 MagJack. The EV kit uses a ...
... The EV kit is a galvanically isolated 25W DC-DC converter using the active-clamped, current-mode PWM controller in a forward, coupled-inductor feedback topology. The EV kit receives power from an IEEE 802.3af/at-compliant PSE and a UTP cable connected to the EV kit’s RJ45 MagJack. The EV kit uses a ...
MAX6397/MAX6398 Overvoltage Protection Switch/Limiter Controllers Operate Up to 72V General Description
... output load or limit the output voltage during an input overvoltage condition. These devices are ideal for applications that must survive high-voltage transients such as those found in automotive and industrial applications. The MAX6397/MAX6398 monitor the input or output voltages and control an ext ...
... output load or limit the output voltage during an input overvoltage condition. These devices are ideal for applications that must survive high-voltage transients such as those found in automotive and industrial applications. The MAX6397/MAX6398 monitor the input or output voltages and control an ext ...
MAX15090/MAX15090A Evaluate: MAX15090/MAX15090A Evaluation Kits General Description
... Note: Indicate that you are using the MAX15090 when contacting these component suppliers. ...
... Note: Indicate that you are using the MAX15090 when contacting these component suppliers. ...
494-148
... electronics. Due to extensive use of power control devices, an increasing deviation of the system voltage and current waveforms is observed. The presence of harmonics in the power lines results in greater power losses and excessive heating of electrical equipment in the power distribution system. An ...
... electronics. Due to extensive use of power control devices, an increasing deviation of the system voltage and current waveforms is observed. The presence of harmonics in the power lines results in greater power losses and excessive heating of electrical equipment in the power distribution system. An ...
2.1 materials
... Interior Daylight sensor: A Photosensor mounted on or near the interior of the framing system to measure the amount of light coming through electrochromic glazing; used for automatic control of tint level to achieve consistent daylighting. ...
... Interior Daylight sensor: A Photosensor mounted on or near the interior of the framing system to measure the amount of light coming through electrochromic glazing; used for automatic control of tint level to achieve consistent daylighting. ...
MAX9890 Audio Click-Pop Suppressor General Description Features
... The MAX9890A features a 200ms switch turn-on time, enabling the use of up to 100µF coupling capacitors at the output for applications requiring only a limited lowfrequency response and a rapid turn-on time. The MAX9890B features a 330ms switch turn-on time, enabling the use of >100µF coupling capaci ...
... The MAX9890A features a 200ms switch turn-on time, enabling the use of up to 100µF coupling capacitors at the output for applications requiring only a limited lowfrequency response and a rapid turn-on time. The MAX9890B features a 330ms switch turn-on time, enabling the use of >100µF coupling capaci ...
13-14 thru 13-26
... amount that one shaft turns is equal to the difference between the amounts that the other two turn. The differential selsyn is named according to the two functions it performs. If the shaft of the differential selsyn serves to indicate the difference in shafts positions of two other selsyns, the oth ...
... amount that one shaft turns is equal to the difference between the amounts that the other two turn. The differential selsyn is named according to the two functions it performs. If the shaft of the differential selsyn serves to indicate the difference in shafts positions of two other selsyns, the oth ...
SMES Modeling Performance Analysis Michael
... It has been observed that energy storage can enhance the performance of a STACOM and possibly reduce the MVA ratings requirements of the STACOM operating alone. This is an important finding for cost/ benefit analysis of FACTS / Power Quality devices. Also the combination of other FACTS / Power Elect ...
... It has been observed that energy storage can enhance the performance of a STACOM and possibly reduce the MVA ratings requirements of the STACOM operating alone. This is an important finding for cost/ benefit analysis of FACTS / Power Quality devices. Also the combination of other FACTS / Power Elect ...
Voltage Regulator TAPCON® 230
... A "PARAM?" message appearing in the first line of the display indicates a negative result of the parameter verification that may be caused by interference above the permissible electromagnetic compatibility limit (see information on standardisation and verification in section 2). In this case, volta ...
... A "PARAM?" message appearing in the first line of the display indicates a negative result of the parameter verification that may be caused by interference above the permissible electromagnetic compatibility limit (see information on standardisation and verification in section 2). In this case, volta ...
Using the Latest Wolfspeed C3MTM SiC MOSFETs to Simplify
... value. So we have a gate charge for the SiC device that is an order of magnitude lower than what is seen for the other devices. Likewise, the Ciss is orders of magnitude smaller, as is the Coss. And the switching speed is significantly lower. What all those parameters mean is very short dead times a ...
... value. So we have a gate charge for the SiC device that is an order of magnitude lower than what is seen for the other devices. Likewise, the Ciss is orders of magnitude smaller, as is the Coss. And the switching speed is significantly lower. What all those parameters mean is very short dead times a ...
AT04296: Low Power Features of SAM L Series Devices
... responsiveness with power consumption. A standard low power technique is to limit the amount of time a device spends in active mode by increasing the time spent in low power sleep modes. The features described in this application note allows the device to perform tasks, while active or in a sleep mo ...
... responsiveness with power consumption. A standard low power technique is to limit the amount of time a device spends in active mode by increasing the time spent in low power sleep modes. The features described in this application note allows the device to perform tasks, while active or in a sleep mo ...
Old Company Name in Catalogs and Other Documents
... All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renes ...
... All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renes ...
SECTION 26 51 13 INTERIOR LIGHTING FIXTURES, LAMPS, AND
... Installer of Electronic Ballast Lighting System to coordinate a meeting of the mechanical and electrical engineer, mechanical and electrical contractor, lighting, window shade and HVAC equipment manufacturers. Include any designers and contractors for any other direct digital control system designed ...
... Installer of Electronic Ballast Lighting System to coordinate a meeting of the mechanical and electrical engineer, mechanical and electrical contractor, lighting, window shade and HVAC equipment manufacturers. Include any designers and contractors for any other direct digital control system designed ...
Article 555 Marinas and Boatyards
... Water level isn’t constant. Ocean tides rise and fall, while lakes and rivers vary in depth in response to rain. To provide power to a marina or boatyard, you must allow for these variations in water level between the point of use and the power source. Article 555 addresses this issue. This article ...
... Water level isn’t constant. Ocean tides rise and fall, while lakes and rivers vary in depth in response to rain. To provide power to a marina or boatyard, you must allow for these variations in water level between the point of use and the power source. Article 555 addresses this issue. This article ...
Bus Ele DS 5022 TPM TPMDS
... Voltage Directive (50-1000VAC, 75-1500VDC). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. ...
... Voltage Directive (50-1000VAC, 75-1500VDC). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. ...
PowerLogic™ DM6000 Series Digital Meters Quick Start Guide
... Turn off all power supplying the digital meter and the equipment in which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that all power is off. Before closing all covers and doors, inspect the work area for tools and objects that may have been lef ...
... Turn off all power supplying the digital meter and the equipment in which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that all power is off. Before closing all covers and doors, inspect the work area for tools and objects that may have been lef ...
PDF: 2.09MB
... With SiC, owing to the high dielectric breakdown, power loss is reduced and high-voltage is easier to achieve, it is possible to use Schottky Barrier Diodes (SBDs), which cannot be used with Si. SBDs can realize high-speed switching motion because they don't have accumulation carriers. As a result, ...
... With SiC, owing to the high dielectric breakdown, power loss is reduced and high-voltage is easier to achieve, it is possible to use Schottky Barrier Diodes (SBDs), which cannot be used with Si. SBDs can realize high-speed switching motion because they don't have accumulation carriers. As a result, ...
Wireless power and data transfer
... primary side and the pickup side plays an essential role in a well-designed WPT system. For instance, the functions such as output voltage feedback control, load detection, status monitoring, auto-tuning and multi-controllers synchronization are generally required in WPT systems [12-17], which can b ...
... primary side and the pickup side plays an essential role in a well-designed WPT system. For instance, the functions such as output voltage feedback control, load detection, status monitoring, auto-tuning and multi-controllers synchronization are generally required in WPT systems [12-17], which can b ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...
... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...