NX3L1T3157 1. General description Low-ohmic single-pole double-throw analog switch
... The NX3L1T3157 is a low-ohmic single-pole double-throw analog switch suitable for use as an analog or digital 2:1 multiplexer/demultiplexer. It has a digital select input (S), two independent inputs/outputs (Y0 and Y1) and a common input/output (Z). Schmitt trigger action at the digital input makes ...
... The NX3L1T3157 is a low-ohmic single-pole double-throw analog switch suitable for use as an analog or digital 2:1 multiplexer/demultiplexer. It has a digital select input (S), two independent inputs/outputs (Y0 and Y1) and a common input/output (Z). Schmitt trigger action at the digital input makes ...
Cutler-Hammer Instructions for 36" Wide Vacuum-Break
... environmentally-immune coil shell, which also contains a full-wave silicon diode rectifier. An AC or DC source can be connected to terminals A and B on the coil shell. When an AC source is applied, the rectifier converts the AC to unfiltered DC to excite the magnet. When a DC source is applied, only ...
... environmentally-immune coil shell, which also contains a full-wave silicon diode rectifier. An AC or DC source can be connected to terminals A and B on the coil shell. When an AC source is applied, the rectifier converts the AC to unfiltered DC to excite the magnet. When a DC source is applied, only ...
SERIES 18H AC Flux Vector Control
... Operation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... Operation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Andrzej M. Trzynadlowski-Control of Induction Motors (Electrical and
... An electric motor driving a mechanical load, directly or through a gearbox or a V-belt transmission, and the associated control equipment such as power converters, switches, relays, sensors, and microprocessors, constitute an electric drive system. It should be stressed that, as of today, most induc ...
... An electric motor driving a mechanical load, directly or through a gearbox or a V-belt transmission, and the associated control equipment such as power converters, switches, relays, sensors, and microprocessors, constitute an electric drive system. It should be stressed that, as of today, most induc ...
Enhanced Poly-Phase High-Performance Wide-Span Energy Metering IC M90E32AS
... BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and products descriptions at any time without notice. Atmel does not ma ...
... BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and products descriptions at any time without notice. Atmel does not ma ...
Chapter 2 FAULT IMPEDANCE LOOPS AND OVERHEAD LINE
... auto-reclose sequence. This phenomenon is discussed again in Chapter 5 during protection relay operation analysis. Figure 2.3 depicts a two phase-to-earth fault with possible fault impedances existing between phases and phase-to-earth. It will be used to identify the different voltage and current co ...
... auto-reclose sequence. This phenomenon is discussed again in Chapter 5 during protection relay operation analysis. Figure 2.3 depicts a two phase-to-earth fault with possible fault impedances existing between phases and phase-to-earth. It will be used to identify the different voltage and current co ...
ZLM4 OEM Technical Manual Version 3, June 2014
... The ZLM4 is a 4 zone low voltage electric fence monitor. The ZLM4 may be used by itself or in conjunction with a number of high voltage security electric fence energisers. The ZLM4 monitors up to 4 loops of fence wire, each up to several hundred meters long, to detect someone tampering with the fenc ...
... The ZLM4 is a 4 zone low voltage electric fence monitor. The ZLM4 may be used by itself or in conjunction with a number of high voltage security electric fence energisers. The ZLM4 monitors up to 4 loops of fence wire, each up to several hundred meters long, to detect someone tampering with the fenc ...
SIMULATIONS AND PRACTICAL DESIGNS OF FLYBACK
... waveforms often need to be attenuated by dampers. The output voltage now includes the capacitor ESR contribution, an effect of the current discontinuity at the switch opening. The reflected voltage includes the diode forward drop, as it sums up with the output voltage on the secondary side upper ter ...
... waveforms often need to be attenuated by dampers. The output voltage now includes the capacitor ESR contribution, an effect of the current discontinuity at the switch opening. The reflected voltage includes the diode forward drop, as it sums up with the output voltage on the secondary side upper ter ...
LEEP System 1000® Workstation
... with LEEP Electrosurgical Accessories. DO NOT use this equipment for any purpose other than that for which it has been designed. See warnings and caution statements throughout this manual. ...
... with LEEP Electrosurgical Accessories. DO NOT use this equipment for any purpose other than that for which it has been designed. See warnings and caution statements throughout this manual. ...
section 261300 - medium voltage outdoor metal clad
... Drawings and general provisions of the Subcontract apply to this Section. ...
... Drawings and general provisions of the Subcontract apply to this Section. ...
Cleco electric service standards.
... Added Fig. V-1A Multiple Occupancy Structures-Underground with up to 6 Service Laterals277/480V and Fig. V-3A Multiple Occupancy Structures-Overhead with up to 6 Service Laterals-277/480V. The following Sections were modified: 7.20, 8.14, and A4. Modified wording to have customer provide and install ...
... Added Fig. V-1A Multiple Occupancy Structures-Underground with up to 6 Service Laterals277/480V and Fig. V-3A Multiple Occupancy Structures-Overhead with up to 6 Service Laterals-277/480V. The following Sections were modified: 7.20, 8.14, and A4. Modified wording to have customer provide and install ...
Business Practice Manual for Direct Telemetry Version
... Initial BPM submittal document Added requirement for data quality flag propagation as new Section 6.8, added requirement for preliminary revenue metering package to Section 10.2, removed unnecessary definitions from Section 4, and made changes to ISP circuit exceptions in Section 5.3 per BPM PRR 489 ...
... Initial BPM submittal document Added requirement for data quality flag propagation as new Section 6.8, added requirement for preliminary revenue metering package to Section 10.2, removed unnecessary definitions from Section 4, and made changes to ISP circuit exceptions in Section 5.3 per BPM PRR 489 ...
LTM4601A/LTM4601A-1 - 12A DC/DC uModules with PLL, Output Tracking and Margining
... above 2V and below INTVCC. See the Applications Information section. TRACK/SS (Pin A9): Output Voltage Tracking and SoftStart Pin. When the module is configured as a master output, then a soft-start capacitor is placed on this pin to ground to control the master ramp rate. A soft-start capacitor can ...
... above 2V and below INTVCC. See the Applications Information section. TRACK/SS (Pin A9): Output Voltage Tracking and SoftStart Pin. When the module is configured as a master output, then a soft-start capacitor is placed on this pin to ground to control the master ramp rate. A soft-start capacitor can ...
1 Introduction to 3 phase induction motors
... The squirrel cage rotor is made up of several thin electrical steel lamination (0.5mm) with evenly spaced bars , which are made up of aluminum or copper , along the periphery .In the most popular type of rotor (squirrel cage rotor) , these bars are connected at ends mechanically and electrically by ...
... The squirrel cage rotor is made up of several thin electrical steel lamination (0.5mm) with evenly spaced bars , which are made up of aluminum or copper , along the periphery .In the most popular type of rotor (squirrel cage rotor) , these bars are connected at ends mechanically and electrically by ...
Installation Manual
... Cleaning the Inverter ................................................................ 77 Checking the PV Plant for Earth Faults..................................... 77 Checking the Function of the Varistors..................................... 79 Replacing the Varistors ............................ ...
... Cleaning the Inverter ................................................................ 77 Checking the PV Plant for Earth Faults..................................... 77 Checking the Function of the Varistors..................................... 79 Replacing the Varistors ............................ ...
Catalog IC 10 · 2014 Chapter 5
... Low-voltage switchgear and controlgear, Special requirements for positivelydriven contacts ...
... Low-voltage switchgear and controlgear, Special requirements for positivelydriven contacts ...
Service Manual SUNNY BOY 1300TL / 1600TL / 2100TL SB13-21TL-SG-en-10 | Version 1.0 AMERICAN ENGLISH
... 2 Safety 2.1 Skills of Qualified Persons The tasks described in this document must only be performed by qualified persons. Qualified persons must have the following skills: • Knowledge of how an inverter works and is operated • Training in how to deal with the dangers and risks associated with insta ...
... 2 Safety 2.1 Skills of Qualified Persons The tasks described in this document must only be performed by qualified persons. Qualified persons must have the following skills: • Knowledge of how an inverter works and is operated • Training in how to deal with the dangers and risks associated with insta ...
Switch Mode Power Supply (15/25/35/50/75/100/150/200/350
... • Global Standards: Conforms to CE (all models), Approved for UL (all models) and CCC (15 to 150-W models). • Easy mounting to DIN Rails with Mounting Brackets. * Refer to Period and Terms of Warranty on page 39. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 36. ...
... • Global Standards: Conforms to CE (all models), Approved for UL (all models) and CCC (15 to 150-W models). • Easy mounting to DIN Rails with Mounting Brackets. * Refer to Period and Terms of Warranty on page 39. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 36. ...
TPS65982 USB Type-C and USB PD Controller, Power Switch and
... power. An additional bidirectional switch path provides USB PD power up to 3 A at a maximum of 20 V as either a source (host), sink (device), or source-sink. The TPS65982 is also an upstream-facing port (UFP), downstream-facing port (DFP), or dual-role port for data. The port data multiplexer passes ...
... power. An additional bidirectional switch path provides USB PD power up to 3 A at a maximum of 20 V as either a source (host), sink (device), or source-sink. The TPS65982 is also an upstream-facing port (UFP), downstream-facing port (DFP), or dual-role port for data. The port data multiplexer passes ...