J. Lu, D.J. Perreault, D. Otten, and K.K. Afridi, “Impedance Control Network Resonant Converter for Wide-Range High-Efficiency Operation,” IEEE Transactions on Power Electronics , (to appear).
... inverter leg start to turn off at large currents. Also, as outphasing is increased further, the transistors in the lagging inverter leg lose ZVS turn-on capability. These factors result in extra losses and lead to lower converter efficiency at partial loads, and consequently to poor design tradeoffs ...
... inverter leg start to turn off at large currents. Also, as outphasing is increased further, the transistors in the lagging inverter leg lose ZVS turn-on capability. These factors result in extra losses and lead to lower converter efficiency at partial loads, and consequently to poor design tradeoffs ...
EMI Conducted Interference
... Where MIL-STD-461D, E or F is a system requirement, it is important to recognize any problems early in the design since correcting them will involve adding components as suggested above. You can find these documents at http://quicksearch.dla. mil. The stability problem due to a 50 µhenry inductor in ...
... Where MIL-STD-461D, E or F is a system requirement, it is important to recognize any problems early in the design since correcting them will involve adding components as suggested above. You can find these documents at http://quicksearch.dla. mil. The stability problem due to a 50 µhenry inductor in ...
Reset Circuit for the TMS320C6000 DSP
... This document describes two solutions used to provide a reset circuit to the Texas Instruments (TI™) TMS320C6000 digital signal processor (DSP). One solution sets a supply voltage supervisor, such as the TI TLC7733 and TLC7725, on each of the supply voltages, DVdd and CVdd. Another solution monitors ...
... This document describes two solutions used to provide a reset circuit to the Texas Instruments (TI™) TMS320C6000 digital signal processor (DSP). One solution sets a supply voltage supervisor, such as the TI TLC7733 and TLC7725, on each of the supply voltages, DVdd and CVdd. Another solution monitors ...
- Macquarie University ResearchOnline
... A DC-DC converter performs the same function for DC signals as a step-up or stepdown transformer does in case of AC signals, i.e. of increasing or decreasing voltage level at the output relative the input. Converters which have capability to output voltage lower than input are called Buck converters ...
... A DC-DC converter performs the same function for DC signals as a step-up or stepdown transformer does in case of AC signals, i.e. of increasing or decreasing voltage level at the output relative the input. Converters which have capability to output voltage lower than input are called Buck converters ...
Thermo-Flo™
... About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on all models of Flowline Thermo‐Flo™ Flow Switches: FT10 and GT10 series. Please refer to the part number located on the switch label to verify the exact mo ...
... About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on all models of Flowline Thermo‐Flo™ Flow Switches: FT10 and GT10 series. Please refer to the part number located on the switch label to verify the exact mo ...
Artificial Neural Network Based Fault Locator for Single Line
... Transmission line is used to deliver bulk amount of power from power stations to load centers and large industrial consumers. To increase transmission capacity and enhance reliability parallel transmission lines have been widely adopted in modern power systems. In double circuit transmission line, t ...
... Transmission line is used to deliver bulk amount of power from power stations to load centers and large industrial consumers. To increase transmission capacity and enhance reliability parallel transmission lines have been widely adopted in modern power systems. In double circuit transmission line, t ...
Introductory Circuit Analysis, Tenth Edition
... 4. How much charge is deposited on the plates of a 0.05-mF capacitor if 45 V are applied across the capacitor? 5. Find the electric field strength between the plates of a parallel plate capacitor if 100 mV are applied across the plates and the plates are 2 mm apart. 6. Repeat Problem 5 if the plates ...
... 4. How much charge is deposited on the plates of a 0.05-mF capacitor if 45 V are applied across the capacitor? 5. Find the electric field strength between the plates of a parallel plate capacitor if 100 mV are applied across the plates and the plates are 2 mm apart. 6. Repeat Problem 5 if the plates ...
Room Controller applications for additional occupancy sensors
... Applications that require more than one occupancy sensor can easily exceed the maximum allowable current output from the Room Controller low voltage accessory ports, which is 90mA. It is possible to connect additional occupancy sensors by using a Greengate switchpack to provide the necessary power. ...
... Applications that require more than one occupancy sensor can easily exceed the maximum allowable current output from the Room Controller low voltage accessory ports, which is 90mA. It is possible to connect additional occupancy sensors by using a Greengate switchpack to provide the necessary power. ...
An ultralow-energy adc for smart dust - Solid
... Prototypes of this mote (without the accelerometer) have previously been demonstrated [5]. The ADC design specifications can be roughly grouped into two categories. There are certain system-level constraints based on the construction of the sensor node itself, and applicationlevel constraints that a ...
... Prototypes of this mote (without the accelerometer) have previously been demonstrated [5]. The ADC design specifications can be roughly grouped into two categories. There are certain system-level constraints based on the construction of the sensor node itself, and applicationlevel constraints that a ...
FEATURES GENERAL DESCRIPTION
... isolated, regulated 15 V output supply. Connect the return of the load to Pin 7 of J6. It is labeled GND ISO on the silkscreen and GND4 in the schematic. Side 2 is powered by the secondary isolated 15 V supply. The ADuM3471 internal low-dropout regulator converts this voltage to 5 V. The regulated 5 ...
... isolated, regulated 15 V output supply. Connect the return of the load to Pin 7 of J6. It is labeled GND ISO on the silkscreen and GND4 in the schematic. Side 2 is powered by the secondary isolated 15 V supply. The ADuM3471 internal low-dropout regulator converts this voltage to 5 V. The regulated 5 ...
MAX5090A/B/C 2A, 76V, High-Efficiency MAXPower Step-Down DC-DC Converters General Description
... The MAX5090A/B/C easy-to-use, high-efficiency, highvoltage step-down DC-DC converters operate from an input voltage up to 76V, and consume only 310µA quiescent current at no load. This pulse-width-modulated (PWM) converter operates at a fixed 127kHz switching frequency at heavy loads, and automatica ...
... The MAX5090A/B/C easy-to-use, high-efficiency, highvoltage step-down DC-DC converters operate from an input voltage up to 76V, and consume only 310µA quiescent current at no load. This pulse-width-modulated (PWM) converter operates at a fixed 127kHz switching frequency at heavy loads, and automatica ...
Three-phase Transformers
... Autotransformer (ต่อ) Fig.11c Single-phase autotransformer (one of a group of three) connecting a 700 kV, 3-phase, 60 Hz transmission line to an existing 300 kV system. The transformer ratio is 404 kV/173 kV, to give an output of 200/267/333 MVA per transformer, at a temperature rise of 55°C. Coolin ...
... Autotransformer (ต่อ) Fig.11c Single-phase autotransformer (one of a group of three) connecting a 700 kV, 3-phase, 60 Hz transmission line to an existing 300 kV system. The transformer ratio is 404 kV/173 kV, to give an output of 200/267/333 MVA per transformer, at a temperature rise of 55°C. Coolin ...
Nonisolated High Step-Up Stacked Converter Based on Boost
... remains [16]. Active clamping approaches also resolve these problems and reduce switching losses, but leads to a complex structure with increased number of switches [17], [18]. In this paper, to obtain a high step-up capability with high efficiency, an alternative structure based on isolated-type co ...
... remains [16]. Active clamping approaches also resolve these problems and reduce switching losses, but leads to a complex structure with increased number of switches [17], [18]. In this paper, to obtain a high step-up capability with high efficiency, an alternative structure based on isolated-type co ...
PAM2846 Description Pin Assignments
... Careful PCB layout is important for proper operation. Use the following guidelines for good PCB layout: 1) Minimize the area of the high current switching loop of the rectifier diode and output capacitor to avoid excessive switching noise. 2) Connect high-current input and output components with sho ...
... Careful PCB layout is important for proper operation. Use the following guidelines for good PCB layout: 1) Minimize the area of the high current switching loop of the rectifier diode and output capacitor to avoid excessive switching noise. 2) Connect high-current input and output components with sho ...
AHK3296 数据资料DataSheet下载
... The AHK3296 requires only one external component: one 1μF ceramic input capacitor (CIN). The AHK3296 can drive six constant output sinks (D1 to D6) each with a maximum current of up to 20.6mA which is set internally. Skyworks S2Cwire serial interface enables the AHK3296 and changes the current sink ...
... The AHK3296 requires only one external component: one 1μF ceramic input capacitor (CIN). The AHK3296 can drive six constant output sinks (D1 to D6) each with a maximum current of up to 20.6mA which is set internally. Skyworks S2Cwire serial interface enables the AHK3296 and changes the current sink ...
File - ELECTRICAL ENGINEERING DEPT, DCE
... Converters required at both end of the line, they are very expensive Converters absorb the reactive power which must be supplied locally Power control is fast and accurate as there is less inertia due to the absent of rotating synchronous machines DC line is restricted to point to point transmission ...
... Converters required at both end of the line, they are very expensive Converters absorb the reactive power which must be supplied locally Power control is fast and accurate as there is less inertia due to the absent of rotating synchronous machines DC line is restricted to point to point transmission ...