MAX8867/MAX8868 Low-Noise, Low-Dropout, 150mA Linear Regulators in SOT23 _______________General Description
... dropout voltages and low quiescent currents in batterypowered systems. Power-supply rejection is 63dB at low frequencies and rolls off above 10kHz. See the Power-Supply Rejection Ratio Frequency graph in the Typical Operating Characteristics. When operating from sources other than batteries, improve ...
... dropout voltages and low quiescent currents in batterypowered systems. Power-supply rejection is 63dB at low frequencies and rolls off above 10kHz. See the Power-Supply Rejection Ratio Frequency graph in the Typical Operating Characteristics. When operating from sources other than batteries, improve ...
Low-Noise, Regulated, Negative Charge-Pump Power Supplies for GaAsFET Bias _______________General Description ____________________________Features
... Use capacitors with low effective series resistance (ESR) to maintain a low dropout voltage (VIN - |VOUT|). The overall dropout voltage is a function of the charge pump’s output resistance and the voltage drop across the linear regulator (N-channel pass transistor). At the 100kHz switching frequency ...
... Use capacitors with low effective series resistance (ESR) to maintain a low dropout voltage (VIN - |VOUT|). The overall dropout voltage is a function of the charge pump’s output resistance and the voltage drop across the linear regulator (N-channel pass transistor). At the 100kHz switching frequency ...
AN-7536 FCS Fast Body Diode MOSFET for Phase-Shifted ZVS PWM Full
... current switching topologies allow for high frequency switching while minimizing the switching loss. The ZVS topology operating at high frequency can improve the efficiency and reduce the size and cost of the power supply resulting in higher power densities. ZVS also reduces the stress on the semico ...
... current switching topologies allow for high frequency switching while minimizing the switching loss. The ZVS topology operating at high frequency can improve the efficiency and reduce the size and cost of the power supply resulting in higher power densities. ZVS also reduces the stress on the semico ...
SG723T - Microsemi
... the suitability of its products and services for any particular purpose, nor does Microsemi assume any liability whatsoever arising out of the application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have been subject to limited testing and s ...
... the suitability of its products and services for any particular purpose, nor does Microsemi assume any liability whatsoever arising out of the application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have been subject to limited testing and s ...
Fundamentals of Applied Electromagnetics
... Example 5.1 Air Line An air line is a transmission line for which air is the dielectric material present between the two conductors, which renders G’ = 0. In addition, the conductors are made of a material with high conductivity so that R’ ≈0. For an air line with characteristic impedance of 50 and ...
... Example 5.1 Air Line An air line is a transmission line for which air is the dielectric material present between the two conductors, which renders G’ = 0. In addition, the conductors are made of a material with high conductivity so that R’ ≈0. For an air line with characteristic impedance of 50 and ...
PUB-NP-279 Q. Describe Newfoundland Power’s protective relaying criteria (standard design
... entering an electrical node must exactly equal the amount of electricity leaving the node. For substation buses, if this rule fails because the electricity flow on transmission lines into the substation bus does not match the electricity flow through to the distribution feeders then it is assumed th ...
... entering an electrical node must exactly equal the amount of electricity leaving the node. For substation buses, if this rule fails because the electricity flow on transmission lines into the substation bus does not match the electricity flow through to the distribution feeders then it is assumed th ...
HECO News - OutBack Power Systems
... Frequency Ride-Through; all others are grid-dependent (other grid-interactive multi-mode inverters are only approved for TrOV-1, and remain blanks for the rest). These HECO test results prove the benefits of OutBack’s products and technologies in providing consistent and stable performance to both a ...
... Frequency Ride-Through; all others are grid-dependent (other grid-interactive multi-mode inverters are only approved for TrOV-1, and remain blanks for the rest). These HECO test results prove the benefits of OutBack’s products and technologies in providing consistent and stable performance to both a ...
DARLINGTON TRANSISTOR ARRAYS
... transistor arrays. Each consists of seven npn Darlington pairs that feature high-voltage outputs with common-cathode clamp diodes for switching inductive loads. The collector-current rating of a single Darlington pair is 500 mA. The Darlington pairs may be paralleled for higher current capability. A ...
... transistor arrays. Each consists of seven npn Darlington pairs that feature high-voltage outputs with common-cathode clamp diodes for switching inductive loads. The collector-current rating of a single Darlington pair is 500 mA. The Darlington pairs may be paralleled for higher current capability. A ...
Presentation Title Here
... the input bias current can increase tremendously This may limit the use of this type of operational amplifier as a comparator ...
... the input bias current can increase tremendously This may limit the use of this type of operational amplifier as a comparator ...
Evaluates: MAX1832–MAX1835 MAX1833 Evaluation Kit General Description Features
... MAX1833 high-efficiency, step-up DC-DC converter for portable hand-held devices. The EV kit accepts a positive input voltage between 1.5V to VOUT and converts it to a 3.3V output for currents up to 150mA. The EV kit provides ultra-low quiescent current and high efficiency for maximum battery life. T ...
... MAX1833 high-efficiency, step-up DC-DC converter for portable hand-held devices. The EV kit accepts a positive input voltage between 1.5V to VOUT and converts it to a 3.3V output for currents up to 150mA. The EV kit provides ultra-low quiescent current and high efficiency for maximum battery life. T ...
Basic Electronics to Test Fixtures
... you hit a bell, it resonates at a frequency depending on the properties of the bell. When radiated energy (photons) hit an atom, the atom resonates at a frequency (or frequencies) also. There is a narrow band of frequencies that we can see from about 400 nm to 700 nm in wavelength. Below this freque ...
... you hit a bell, it resonates at a frequency depending on the properties of the bell. When radiated energy (photons) hit an atom, the atom resonates at a frequency (or frequencies) also. There is a narrow band of frequencies that we can see from about 400 nm to 700 nm in wavelength. Below this freque ...
TT11 Circuit Breakers Name How Circuit Breakers Work by Tom
... running through the circuit always passes through an appliance, which acts as a resistor. In this way, the electrical resistance in appliances limits how much charge can flow through a circuit (with a constant voltage and a constant resistance, the current must also be constant). Appliances are desi ...
... running through the circuit always passes through an appliance, which acts as a resistor. In this way, the electrical resistance in appliances limits how much charge can flow through a circuit (with a constant voltage and a constant resistance, the current must also be constant). Appliances are desi ...
To Pot or Not Two common types of electrical testing are easily
... Also called a “dielectric strength test”, a high‐pot test is just that. It is concerned with the strength of insulation, its ability to withstand voltage stress, rather than with its measurement. Some high‐pots do indeed include meters that indicate current or resista ...
... Also called a “dielectric strength test”, a high‐pot test is just that. It is concerned with the strength of insulation, its ability to withstand voltage stress, rather than with its measurement. Some high‐pots do indeed include meters that indicate current or resista ...
Transformers - Electrical Devices, Instrumentation And
... recommended with certain transformer installations even if fire and dielectric breakdown potentials are low. See the requirements for askarel, LFLI and large oil units in Table 1. A lesser level of protection against high energy faults is that provided by differential relays used with circuit breake ...
... recommended with certain transformer installations even if fire and dielectric breakdown potentials are low. See the requirements for askarel, LFLI and large oil units in Table 1. A lesser level of protection against high energy faults is that provided by differential relays used with circuit breake ...
Analog Devices Welcomes Hittite Microwave Corporation
... noise phase-locked loop applications for inputs from 10 to 1300 MHz. Its combination of high frequency of operation along with its ultra low phase noise floor make possible synthesizers with wide loop bandwidth and low N resulting in fast switching and very low phase noise. When used in conjunction ...
... noise phase-locked loop applications for inputs from 10 to 1300 MHz. Its combination of high frequency of operation along with its ultra low phase noise floor make possible synthesizers with wide loop bandwidth and low N resulting in fast switching and very low phase noise. When used in conjunction ...
MV Switchgear 5kVMetal-Clad Indoor
... A. Where indicated on the drawings, each utility metering vertical section shall contain or provide provisions for current transformers, voltage transformers and any relays as specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by t ...
... A. Where indicated on the drawings, each utility metering vertical section shall contain or provide provisions for current transformers, voltage transformers and any relays as specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by t ...
L1 Science 2010
... examples include: metal elements and alloys, carbon and many metal salts dissolved in water. ...
... examples include: metal elements and alloys, carbon and many metal salts dissolved in water. ...
DNBT8105 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
QS6U22
... Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to applicati ...
... Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to applicati ...
File u208b | allcomponents.ru
... or in the event of unsuccessful triggering. If it is necessary, another triggering pulse is generated after a time lapse of tpp = 4.5 tp and this is repeated until either the triac fires or the half cycle finishes. ...
... or in the event of unsuccessful triggering. If it is necessary, another triggering pulse is generated after a time lapse of tpp = 4.5 tp and this is repeated until either the triac fires or the half cycle finishes. ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".