LT1809/LT1810 - Single/Dual 180MHz, 350V/µs Rail-to-Rail Input and Output Low Distortion Op Amps
... The LT®1809/LT1810 are single/dual low distortion rail-torail input and output op amps with a 350V/μs slew rate. These amplifiers have a –3dB bandwidth of 320MHz at unity-gain, a gain-bandwidth product of 180MHz (AV ≥ 10) and an 85mA output current to fit the needs of low voltage, high performance sig ...
... The LT®1809/LT1810 are single/dual low distortion rail-torail input and output op amps with a 350V/μs slew rate. These amplifiers have a –3dB bandwidth of 320MHz at unity-gain, a gain-bandwidth product of 180MHz (AV ≥ 10) and an 85mA output current to fit the needs of low voltage, high performance sig ...
LTC6403-1 - 200MHz, Low Noise, Low Power Fully Differential Input
... Note 2: The inputs +IN, –IN are protected by a pair of back-to-back diodes. If the differential input voltage exceeds 1.4V, the input current should be limited to less than 10mA. Input pins (+IN, –IN, VOCM, and SHDN) are also protected by steering diodes to either supply. If the inputs should exceed ...
... Note 2: The inputs +IN, –IN are protected by a pair of back-to-back diodes. If the differential input voltage exceeds 1.4V, the input current should be limited to less than 10mA. Input pins (+IN, –IN, VOCM, and SHDN) are also protected by steering diodes to either supply. If the inputs should exceed ...
Single-Chip HID USB to SMBus Master Bridge CP2112 Data Sheet
... 3. SMBus has a maximum requirement of 50 µs for Clock High Period. Operating frequencies lower than 40 kHz will be longer than 50 µs. I2C can support periods longer than 50 µs. ...
... 3. SMBus has a maximum requirement of 50 µs for Clock High Period. Operating frequencies lower than 40 kHz will be longer than 50 µs. I2C can support periods longer than 50 µs. ...
Power system protection
... maintenance costs. Protection costs are considered high when considered alone, but they should be evaluated in the light of the higher cost of the equipment they are protecting, and the cost of an outage or loss of the protected equipment through improper protection. ...
... maintenance costs. Protection costs are considered high when considered alone, but they should be evaluated in the light of the higher cost of the equipment they are protecting, and the cost of an outage or loss of the protected equipment through improper protection. ...
ADS808: 12-Bit, 70MHz Sampling Analog-to
... The ADS808 input structure allows it to be driven either single-ended or differentially. Differential operation of the ADS808 requires an input signal that consists of an in-phase and a 180° out-of-phase component simultaneously applied to the inputs (IN, IN). Differential signals offer a number of ...
... The ADS808 input structure allows it to be driven either single-ended or differentially. Differential operation of the ADS808 requires an input signal that consists of an in-phase and a 180° out-of-phase component simultaneously applied to the inputs (IN, IN). Differential signals offer a number of ...
UM10393 UBA2024P DIP8 13 W demo board User manual
... Conducted emissions have been measured in neutral and line wires using a pre-compliance test setup and considering the limits for lighting applications, i.e. EN55015. The measurements have been performed at 230 V (AC) line voltage. The results are shown in Figure 8 and Figure 9. The emission level i ...
... Conducted emissions have been measured in neutral and line wires using a pre-compliance test setup and considering the limits for lighting applications, i.e. EN55015. The measurements have been performed at 230 V (AC) line voltage. The results are shown in Figure 8 and Figure 9. The emission level i ...
Tutorial Problems
... 1. A 6MW 3 Phase 11 KV, star connected 6 pole 50 Hz 0.9 lagging power factor synchronous motor has synchronous reactance equal to 9Ω and armature resistance equal to 0Ω. The rated field current is 50 A. The machine is controlled by variable frequency control at constant V/F ratio up to the base spee ...
... 1. A 6MW 3 Phase 11 KV, star connected 6 pole 50 Hz 0.9 lagging power factor synchronous motor has synchronous reactance equal to 9Ω and armature resistance equal to 0Ω. The rated field current is 50 A. The machine is controlled by variable frequency control at constant V/F ratio up to the base spee ...
Micropower Electrochemical Gas Sensor
... may hit the rail before the maximum sensor current is achieved. If this incident occurs, proper sensor bias voltage is no longer maintained, the resulting readings are incorrect, and sensor damage is also possible. TI recommends to additionally monitor the CE drive voltage during operation to make s ...
... may hit the rail before the maximum sensor current is achieved. If this incident occurs, proper sensor bias voltage is no longer maintained, the resulting readings are incorrect, and sensor damage is also possible. TI recommends to additionally monitor the CE drive voltage during operation to make s ...
OPA2822 Dual, Wideband, Low-Noise Operational Amplifier FEATURES
... DISCHARGE SENSITIVITY Electrostatic discharge can cause damage ranging from performance degradation to complete device failure. Texas Instruments recommends that all integrated circuits be handled and stored using appropriate ESD protection methods. ESD damage can range from subtle performance degra ...
... DISCHARGE SENSITIVITY Electrostatic discharge can cause damage ranging from performance degradation to complete device failure. Texas Instruments recommends that all integrated circuits be handled and stored using appropriate ESD protection methods. ESD damage can range from subtle performance degra ...
SERVICE MANUAL
... 1- Use only original spare parts. Only use components with the same specifications for replacement. 2- Original fuse value only should be used. 3- Main leads and connecting leads should be checked for external damage before connection. Check the insulation. 4- Parts contributing to the safety of the ...
... 1- Use only original spare parts. Only use components with the same specifications for replacement. 2- Original fuse value only should be used. 3- Main leads and connecting leads should be checked for external damage before connection. Check the insulation. 4- Parts contributing to the safety of the ...
Second Order Circuits I
... 3) For both the inductor current and voltage, determine their initial values, the initial values of their derivatives, and their final values. The capacitor has 9 J of stored energy before the ...
... 3) For both the inductor current and voltage, determine their initial values, the initial values of their derivatives, and their final values. The capacitor has 9 J of stored energy before the ...
Downloaded
... of static voltage stability limits of induction generators and the need for reactive power compensation to allow for introduction of large-scale wind power production in the presence of grid limitations [11]–[14]. Dynamic stability limits and transient stability of induction machines has also been i ...
... of static voltage stability limits of induction generators and the need for reactive power compensation to allow for introduction of large-scale wind power production in the presence of grid limitations [11]–[14]. Dynamic stability limits and transient stability of induction machines has also been i ...
I=V/R
... quiz (extra credit) We saw that if a magnet gets dropped through a pipe made of conducting material, it fall is slowed due to the opposing induced magnetic force. If the pipe was cooled, the velocity of the magnet was even further reduced because current could flow more easily through the pipe and ...
... quiz (extra credit) We saw that if a magnet gets dropped through a pipe made of conducting material, it fall is slowed due to the opposing induced magnetic force. If the pipe was cooled, the velocity of the magnet was even further reduced because current could flow more easily through the pipe and ...
UBA20271/2 350 V and 600 V Power ICs for dimmable compact
... oscillating at fbridge(max). The circuit enters the preheat state as soon as the capacitor on the CP pin is charged to a voltage level higher than Vth(CP)max. To remain oscillating, the VDD voltage must remain higher than VDD(stop) and lower than the upper limit VDD(clamp). In addition, the typical ...
... oscillating at fbridge(max). The circuit enters the preheat state as soon as the capacitor on the CP pin is charged to a voltage level higher than Vth(CP)max. To remain oscillating, the VDD voltage must remain higher than VDD(stop) and lower than the upper limit VDD(clamp). In addition, the typical ...
UM6K33N
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
Mostofa 09221122, Ahmed 09221145, Pia 09221072, Megna 09221136
... The Metal- Semiconductor Field-Effect-Transistor (MESFET) is used as a paragon in RF amplifier due to its lower stray capacitance and immense radiation hardness. It is imperative to develop rigorous IN characteristic models for nanometer size MESFETs. Therefore, we consider two types of MESFETs, GaA ...
... The Metal- Semiconductor Field-Effect-Transistor (MESFET) is used as a paragon in RF amplifier due to its lower stray capacitance and immense radiation hardness. It is imperative to develop rigorous IN characteristic models for nanometer size MESFETs. Therefore, we consider two types of MESFETs, GaA ...
SEW-EURODRIVE Movitrac B
... Frequency inverters are devices for stationary installation in control cabinets. Adhere to all instructions referring to the technical data and the permissible conditions where the unit is operated. Do not start up the unit (take it into operation in the designated fashion) until you have verified t ...
... Frequency inverters are devices for stationary installation in control cabinets. Adhere to all instructions referring to the technical data and the permissible conditions where the unit is operated. Do not start up the unit (take it into operation in the designated fashion) until you have verified t ...
SN74LVTH32374-EP 数据资料 dataSheet 下载
... and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s te ...
... and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s te ...
MAX5099 Dual, 2.2MHz, Automotive Synchronous Buck Converter with 80V Load-Dump Protection General Description
... n-channel MOSFET. When an overvoltage or loaddump condition occurs, the series protection MOSFET absorbs the high voltage transient to prevent damage to lower voltage components. The DC-DC converter operates over a wide 4.5V to 19V operating voltage range. The MAX5099 operates 180° out-of-phase with ...
... n-channel MOSFET. When an overvoltage or loaddump condition occurs, the series protection MOSFET absorbs the high voltage transient to prevent damage to lower voltage components. The DC-DC converter operates over a wide 4.5V to 19V operating voltage range. The MAX5099 operates 180° out-of-phase with ...
Board 3S SKYPER 32 PRO R Gold
... monitored. When the circuit works correctly under rated operation conditions, short-circuit testing may be done, starting again with low collector voltage. It is important to feed any errors back to the control circuit and to switch off the device immediately in failure events. Repeated turn-on of t ...
... monitored. When the circuit works correctly under rated operation conditions, short-circuit testing may be done, starting again with low collector voltage. It is important to feed any errors back to the control circuit and to switch off the device immediately in failure events. Repeated turn-on of t ...
Publication : Design of Full Adder circuit using Double Gate
... The need of designing low power VLSI circuits has been increased immensely due to increased demand of portable devices like palmtops, cellular and mobiles. Further to integrate more number of devices on chip, scaling of device size is required. But there are number of problems in scaling of bulk MOS ...
... The need of designing low power VLSI circuits has been increased immensely due to increased demand of portable devices like palmtops, cellular and mobiles. Further to integrate more number of devices on chip, scaling of device size is required. But there are number of problems in scaling of bulk MOS ...
Design of a 48 V three-phase inverter
... and enable more efficient and advanced functions as heating, ventilation and air conditioning in the car [2]. Car generators of today are usually based on a multiphase electrically magnetized synchronous generator connected to a passive diode rectifier, where the field current is used to regulate th ...
... and enable more efficient and advanced functions as heating, ventilation and air conditioning in the car [2]. Car generators of today are usually based on a multiphase electrically magnetized synchronous generator connected to a passive diode rectifier, where the field current is used to regulate th ...
Surge protector

A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".