• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NODE ANALYSIS
NODE ANALYSIS

...  V1  V2  20[V ] V2 V1  20 V1 V * /10k  V1  V2  100[V ]  2  10mA  0 10k 10k adding : V2  60[V ] V1  100  V2  40[V ] TO COMPUTE THE POWER SUPPLIED BY VOLTAGE SOURCE WE MUST KNOW THE CURRENT THROUGH IT ...
Capacitors - La Favre home page
Capacitors - La Favre home page

IC Temp Sensor Provides Thermocouple Cold
IC Temp Sensor Provides Thermocouple Cold

Girard Awnings R
Girard Awnings R

... on both sides before attaching the top of the enclosure. 5. DO NOT TOUCH any part of the board at any time when it is energized. Note: Motor ground must be connected to maintain electrical safety. If the device does not operate as expected, verify that all wires are securely and correctly connected. ...
Basic Electrical Technology Prof. Dr. L. Umanand Department of
Basic Electrical Technology Prof. Dr. L. Umanand Department of

... Now the capacitor looks something like this in its most primitive form. It has two plates: there is one plate here (Refer Slide Time: 27:42) there is another plate here and in between there is a non-conducting dielectric material. So the charges……….. let us say there is a current flow so the charge ...
Design Considerations for Electrical Fast Transient (EFT)
Design Considerations for Electrical Fast Transient (EFT)

... amplitude (0.5 - 4 kV), short rise time, high repetition rate, and a low energy content. IEC 61000-4-4 also defines test levels based on the amplitude of the pulse waveform. Figure 2 shows the waveform shape as defined in the IEC 61000-4-4 specification. It consists of a burst of 75 pulses repeated ...
CHAPTER 2 : DC METERS
CHAPTER 2 : DC METERS

... The compass and conducting wire meter can be considered a fixed-conductor moving-magnet device since the compass is, in reality, a magnet that is allowed to move. The basic principle of this device is the interaction of magnetic fields: the field of the compass (a permanent magnet) and the field aro ...
View Attachment - Northeast Power Coordinating Council, Inc.
View Attachment - Northeast Power Coordinating Council, Inc.

... accordance with these recommended practices, cables may be routed within the substation in a conventional manner for electric power facilities, whereby instrument cabling is isolated from power cabling. Large facilities may require additional GPS receivers, distribution amplifiers, or fiber optic li ...
Product Guide, Generator protection REG650, IEC
Product Guide, Generator protection REG650, IEC

... language for signal and function engineering. • Minimized parameter setting based on default values and ABB's new global base value concept. You only need to set those parameters specific to your own application, such as the line data. • GOOSE messaging for horizontal communication. • Extended HMI f ...
medium-voltage switchgear
medium-voltage switchgear

... Manufacturer qualifications: The bidder must have at least 15 years experience in manufacturing medium voltage metal-clad switchgear and circuit breakers. The manufacturer of the metal-clad switchgear assembly shall also be the manufacturer of the circuit breakers. ...
Class 2000 Meter
Class 2000 Meter

... is used to bring in MAINS Power (voltage lines to power meter) and current sensor wiring. The 1/2” conduit opening located on the top of the enclosure is used to interface low voltage signals, such as the IDR interface and isolated pulse output. (Outdoor enclosures equipped with one 3/4” conduit ope ...
Datasheet - Infineon Technologies
Datasheet - Infineon Technologies

... output diode allows the designer to choose the most cost-effective solution. The output voltage can be tuned by enabling/disabling the V CC voltage regulator circuitry. Synchronous rectification circuitry is available for selection in the case of high-efficiency applications. Designers can choose to ...
LT3090 – 36V, 600mA Negative Linear
LT3090 – 36V, 600mA Negative Linear

... source load. Therefore, the device is tested while operating in dropout. This is the worst-case GND pin current. GND pin current decreases at higher input voltages. Note 9. The SET pin is clamped to OUT with diodes through 12k resistors. These resistors and diodes only carry current under transient ...
SP3239E 数据资料DataSheet下载
SP3239E 数据资料DataSheet下载

... such as notebook and palmtop computers. The SP3239E uses an internal high-efficiency, charge-pump power supply that requires only 0.1µF capacitors in 3.3V operation. This charge pump and Exar's driver architecture allow the SP3239E device to deliver compliant RS-232 performance from a single power s ...
S270-21-2 (Discontinued)
S270-21-2 (Discontinued)

... sectionalizer (downline fault) and this overcurrent must drop to zero (fault interrupted by the backup protective device). The pulse counter provides storage for up to three pulses. Depending upon the counts-to-open setting, the tripping circuit will turn on after one, two, or three count pulses hav ...
cascaded and hybrid multilevel inverters with reduced number of
cascaded and hybrid multilevel inverters with reduced number of

... require medium voltage and MW power level. For a medium voltage grid, it is troublesome to connect one power semiconductor switch directly [1-2]. High power and medium voltage inverter has recently become a research focus so far as known there are many problems in conventional two level inverter in ...
DC-AC Inverters - Samlex America
DC-AC Inverters - Samlex America

... Although your power inverter has the capacity to provide power output (excess current) equal to approximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous ...
PD166017T1F  Data Sheet INTELLIGENT POWER DEVICE
PD166017T1F Data Sheet INTELLIGENT POWER DEVICE

...  Shutdown with auto-restart on cooling Built-in diagnostic function  Proportional load current sensing  Defined fault signal in case of abnormal load condition Under voltage lock out Reverse battery protection by self turn on of N-ch MOSFET ...
Aalborg Universitet
Aalborg Universitet

... systems [1], [2]. The switching frequency of the semiconductor devices, used in medium/high power applications, is often limited [3]. Therefore, such systems may require large filter components to meet the stringent power quality requirements imposed by the utility [4]. The use of the large filter c ...
Power Factor and Generators
Power Factor and Generators

2 x 210 Watt STEREO DIGITAL AMPLIFIER
2 x 210 Watt STEREO DIGITAL AMPLIFIER

... PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. ...
Lightning on transmission line of the harm and prevention measures
Lightning on transmission line of the harm and prevention measures

... operation of the contradiction of the more prominent. Such as 500 kV line, the line running at full capacity, when the lightning tripping, due to the line with transfer to instantaneous load, will cause multiple substation of 220 kV and below power outages, the direct causes of the entire region's ...
LAE-2012-008-T - MIT Laboratory for Aviation and the Environment
LAE-2012-008-T - MIT Laboratory for Aviation and the Environment

MT-044: Op Amp Open Loop Gain and Open Loop
MT-044: Op Amp Open Loop Gain and Open Loop

... (VFB) op amps is quite high. Common values are 100,000 to 1,000,000, and 10 or 100 times these figures for high precision parts. Some fast op amps have appreciably lower open-loop gain, but gains of less than a few thousand are unsatisfactory for high accuracy use. Note also that open-loop gain isn' ...
Transponder power supply, a transponder and a method for
Transponder power supply, a transponder and a method for

... case). In other words, the voltage of the antenna input signal 102 is strongly dependent on the distance between transpon der and transponder reader. The voltage of the antenna input signal 102 may therefore be even below the above mentioned 5 V, but by using the transponder power supply 100 shown i ...
< 1 ... 111 112 113 114 115 116 117 118 119 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".