User Manual V1.03 - Scavenger Transmitter Module STM
... are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOc ...
... are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOc ...
EZ-PD™ CCG2 Datasheet USB Type
... VCONN pins on a Type-C plug of a cable or VCONN-powered accessory. Each of these inputs support operation over 4.0 to 5.5 V. An internal isolation between VCONN1 and VCONN2 pins is provided allowing them to be at different levels simultaneously. CCG2 can be used in EMCA applications with only one or ...
... VCONN pins on a Type-C plug of a cable or VCONN-powered accessory. Each of these inputs support operation over 4.0 to 5.5 V. An internal isolation between VCONN1 and VCONN2 pins is provided allowing them to be at different levels simultaneously. CCG2 can be used in EMCA applications with only one or ...
SIPROTEC Compact 7SD80, 7SJ80, 7SJ81, 7SK80, 7SK81, 7RW80
... sector, but it can of course also be used for other applications such as high-voltage switchgear, for example. The outstanding feature of the SIPROTEC Compact series is the compact design offering, at the same time, a high functional density and user friendliness. In the development of the SIPROTEC ...
... sector, but it can of course also be used for other applications such as high-voltage switchgear, for example. The outstanding feature of the SIPROTEC Compact series is the compact design offering, at the same time, a high functional density and user friendliness. In the development of the SIPROTEC ...
Ch4. LLC Resonant Converter
... voltage increases, the converter is working at higher frequency away from resonant frequency. As frequency increases, the impedance of the resonant tank is increased. This means more and more energy is circulating in the resonant tank instead of transferred to output. From simulation waveforms, at 3 ...
... voltage increases, the converter is working at higher frequency away from resonant frequency. As frequency increases, the impedance of the resonant tank is increased. This means more and more energy is circulating in the resonant tank instead of transferred to output. From simulation waveforms, at 3 ...
Harmonic management of transmission and distribution systems
... computer power supplies and battery chargers[10-12]. For example, standard industrial variable speed drives use the dc or induction motor with thyristor or rectifier respectively. The converters which produce a high frequency supply will b e c o m e more c o m m o n to be used for lighting systems d ...
... computer power supplies and battery chargers[10-12]. For example, standard industrial variable speed drives use the dc or induction motor with thyristor or rectifier respectively. The converters which produce a high frequency supply will b e c o m e more c o m m o n to be used for lighting systems d ...
IP4786CZ32S
... high-speed Transition-Minimized Differential Signaling (TMDS) lines to simplify routing and help reduce impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA over ...
... high-speed Transition-Minimized Differential Signaling (TMDS) lines to simplify routing and help reduce impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA over ...
Chapter 2 - Automation Direct
... • The Instruction List window displays all available CLICK PLC instructions, allows you to drag and drop the instruction into your ladder logic program, and then enter any values and/or parameters required for the particular instruction. • You can add Subroutine and Interrupt programs separately f ...
... • The Instruction List window displays all available CLICK PLC instructions, allows you to drag and drop the instruction into your ladder logic program, and then enter any values and/or parameters required for the particular instruction. • You can add Subroutine and Interrupt programs separately f ...
1395 Digital DC Drive
... contamination of printed circuit boards (PCB), and connections that are damaged or improperly seated, etc., can cause serious malfunctions to occur in the 1395 drive. An attempt should be made to correct any of these environmental conditions prior to installing new components. ...
... contamination of printed circuit boards (PCB), and connections that are damaged or improperly seated, etc., can cause serious malfunctions to occur in the 1395 drive. An attempt should be made to correct any of these environmental conditions prior to installing new components. ...
All about ignition coils - BERU® by Federal
... fuel / air mixture must be ignited at the right time with the optimum ignition energy so that complete combustion occurs. To reduce fuel consumption and emissions and to increase the efficiency, engine technologies are constantly developed further – and thus also the BERU ignition systems. In partic ...
... fuel / air mixture must be ignited at the right time with the optimum ignition energy so that complete combustion occurs. To reduce fuel consumption and emissions and to increase the efficiency, engine technologies are constantly developed further – and thus also the BERU ignition systems. In partic ...
Agilent 34401A Digital Multimeter
... any unauthorized modification to the product. Return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained. Ground the Instrument If your product is provided with a grounding-type power plug, the instrument chassis and co ...
... any unauthorized modification to the product. Return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained. Ground the Instrument If your product is provided with a grounding-type power plug, the instrument chassis and co ...
70B-ROP-2002-Recommended Practice for Electrical
... on of a successful EPM program. No EPM program can operate without them, and their importance cannot be overemphasized. The diagrams discussed in the following paragraphs are some of those in common use. 4-2.3.1. Single-line diagrams show the electrical circuitry down to, and often including, the ma ...
... on of a successful EPM program. No EPM program can operate without them, and their importance cannot be overemphasized. The diagrams discussed in the following paragraphs are some of those in common use. 4-2.3.1. Single-line diagrams show the electrical circuitry down to, and often including, the ma ...
“FAULT TOLERANT VECTOR CONTROL OF FIVE-PHASE PERMANENT MAGNET MOTORS”
... Under faulty conditions, appropriate reference currents of a five-phase BLDC machine have oscillating dynamics both in phase and rotating reference frames. As a result, the implemented current controllers under these conditions should be robust and fast. Predictive deadbeat controllers are also prop ...
... Under faulty conditions, appropriate reference currents of a five-phase BLDC machine have oscillating dynamics both in phase and rotating reference frames. As a result, the implemented current controllers under these conditions should be robust and fast. Predictive deadbeat controllers are also prop ...
74HC4851; 74HCT4851 1. General description 8-channel analog multiplexer/demultiplexer with
... The 74HC4851; 74HCT4851 are high-speed Si-gate CMOS devices and are specified in compliance with JEDEC standard no. 7A. The 74HC4851; 74HCT4851 are 8-channel analog multiplexers/demultiplexers with three digital select inputs (S0 to S2), an active-LOW enable input (E), eight independent inputs/outpu ...
... The 74HC4851; 74HCT4851 are high-speed Si-gate CMOS devices and are specified in compliance with JEDEC standard no. 7A. The 74HC4851; 74HCT4851 are 8-channel analog multiplexers/demultiplexers with three digital select inputs (S0 to S2), an active-LOW enable input (E), eight independent inputs/outpu ...
Distribution Dry-Type Transformers — Low Voltage
... Inrush current: The initial high peak of current that occurs in the first few cycles of energization, which can be 30 to 40 times the rated current. ...
... Inrush current: The initial high peak of current that occurs in the first few cycles of energization, which can be 30 to 40 times the rated current. ...
STM1810
... Supply current vs. temperature (no load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Normalized reset time-out period (trec) vs. temperature - VOD = VTH – VCC . . . . . . . . . . . 13 VCC-to-reset output delay vs. temperature - VOD = VTH – VCC . . . . . . . . . . . ...
... Supply current vs. temperature (no load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Normalized reset time-out period (trec) vs. temperature - VOD = VTH – VCC . . . . . . . . . . . 13 VCC-to-reset output delay vs. temperature - VOD = VTH – VCC . . . . . . . . . . . ...
IP4786CZ32S DVI and HDMI interface ESD and overcurrent
... high-speed Transition-Minimized Differential Signaling (TMDS) lines to simplify routing and help reduce impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA over ...
... high-speed Transition-Minimized Differential Signaling (TMDS) lines to simplify routing and help reduce impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA over ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.