• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
P83933
P83933

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can rad ...
ABB drives - Technical guide No. 5 - Bearing currents in modern AC
ABB drives - Technical guide No. 5 - Bearing currents in modern AC

... the three phases always equals zero. Thus, it is normal that the neutral is at zero volts. However, this is not the case with a PWM switched three-phase power supply, where a dc voltage is converted into three phase voltages. Even though the fundamental frequency components of the output voltages ar ...
Quadruple Line Receiver (Rev. B)
Quadruple Line Receiver (Rev. B)

... and for level translators. Operation is normally from a single 5-V supply; however, a built-in option allows operation from a 12-V supply without the use of additional components. The output is compatible with most TTL circuits when either supply voltage is used. In normal operation, the threshold-c ...
Fast Track Troubleshooting
Fast Track Troubleshooting

... measure any of the high voltages --this includes the filament voltage of the magnetron. High voltage is present during any cook cycle. Before touching any components or wiring, always unplug the oven and discharge the ...
NFPA 70E and Electrical Testing Safety
NFPA 70E and Electrical Testing Safety

Inter-system Ground Noise: Causes and Effects
Inter-system Ground Noise: Causes and Effects

... It may be apparent that the source of all of these problems is the ground loop caused by the electrical safety ground. In many cases, disconnection of this ground at one piece of equipment may prevent problems. However, ground wire disconnection should never be performed because it is illegal and pr ...
TPS51117 Single Synchronous Step-Down
TPS51117 Single Synchronous Step-Down

... Figure 1. PWM Supply Current vs Junction Temperature ...
Technical Specification PQ60120QEx25 35-75V
Technical Specification PQ60120QEx25 35-75V

... REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). ...
parameters which affect real and reactive power flow
parameters which affect real and reactive power flow

... Fig. 7 Direction of real and reactive power flow Reactive power flows from the sender to the receiver, and 1000 kvar are absorbed in the transmission line during transit. As can be seen, reactive power flows from the high-voltage to the low-voltage side. Sender and receiver voltages are the same, bu ...
Current Source Inverter
Current Source Inverter

... In the previous six (5.1-5.6) lessons in this module, the circuit and operation of single-phase and three-phase Voltage Source Inverters (VSI), with waveforms, were described in detail. Also, the presence of harmonics in voltage waveforms, along with its reduction mainly by Pulse Width Modulation (P ...
To read a diagram, we must understand a circuit. Here is Dictionary
To read a diagram, we must understand a circuit. Here is Dictionary

... The numbers correspond with wires in the motor. The lines going to them from outside the circle are wires coming from the control box, or going to the brake. The start windings are numbers 8 and 5. The diagram should show a connection between the two as they are connected by a motor centrifugal sta ...
8-Channel ESD Protection Array
8-Channel ESD Protection Array

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
Harmonics and IEEE 519
Harmonics and IEEE 519

... problems of voltage distortion and telephone interference. A parallel resonant circuit can amplify harmonic current levels to a point where equipment can fail. Series resonant circuits can concentrate the flow of harmonic currents in specific lines or feeders to a point where telephone interference ...
EHV AC Substations : Layout, Equipment, Bus arrangements
EHV AC Substations : Layout, Equipment, Bus arrangements

... Provides low impedance path to fault currents to ensure prompt and consistent operation of protective device ...
Open-End-Winding PMSG for Wind Energy Conversion System with
Open-End-Winding PMSG for Wind Energy Conversion System with

... they do not consume reactive power, diode rectifiers at generator side followed by dc-dc boost stage and a grid tied two-level voltage source converter have also been adopted in industry as a cost effective and higher power density solution. Multiple three phase winding PMSG have also become popular ...
New Efficient Bridgeless Cuk Rectifiers for PFC Applications
New Efficient Bridgeless Cuk Rectifiers for PFC Applications

... generating losses is reduced by essentially eliminating the fullbridge input diode rectifier. A bridgeless PFC rectifier allows the current to flow through a minimum number of switching devices compared to the conventional PFC rectifier. Accordingly, the converter conduction losses can be significan ...
PDF
PDF

... phase shift between its two sets of output terminals. Instead of accepting these tradeoffs as limitations, a nineswitch power conditioner is proposed here that virtually “converts” most of these topological short comings into interesting performance advantages. Aiming further to reduce its switching ...
SIGC186T170R3E
SIGC186T170R3E

... systems and/or automotive, aviation and aerospace applications or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support, automotive, aviation and aerospace device or system or to a ...
Chapter 7 – Troubleshooting
Chapter 7 – Troubleshooting

... width. Therefore, you can shorten the factor analysis time. In addition, the alarm output voltage can be easily measured by connecting a 1.3 KΩ resistor in series between the IPM alarm terminal and the cathode terminal of the alarming photodiode. ...
MAX9180 400Mbps, Low-Jitter, Low-Noise LVDS Repeater in an SC70 Package General Description
MAX9180 400Mbps, Low-Jitter, Low-Noise LVDS Repeater in an SC70 Package General Description

... Note 1: All devices are 100% tested at TA = +25°C. Limits over temperature are guaranteed by design and characterization. Note 2: Current into a pin is defined as positive. Current out of a pin is defined as negative. All voltages are referenced to ground except VTH, VTL, VOD, and ∆VOD. Note 3: Guar ...
ADM1181A 数据手册DataSheet 下载
ADM1181A 数据手册DataSheet 下载

... Charge-Pump DC-to-DC Voltage Converter The charge-pump voltage converter consists of a 200 kHz oscillator and a switching matrix. The converter generates a ±10 V supply from the input 5 V level. This is done in two stages, using a switched capacitor technique, as illustrated in Figure 6 and Figure 7 ...
Faculty Websites
Faculty Websites

File - Des Moines Modelaires
File - Des Moines Modelaires

LL XX MM GG 11 66 22 66 -- 11 22 -- 66 44
LL XX MM GG 11 66 22 66 -- 11 22 -- 66 44

Tesla Coil Tuning - hot
Tesla Coil Tuning - hot

... From Figure 3 it can be easily seen that the maximum V2 value is now reached with T=1, regardless of the value of m (anyway, m has to be an integer as seen before). In practice, on a real Tesla Coil the secondary winding cannot be easily modified but the primary tap can be moved with no problem. At ...
< 1 ... 581 582 583 584 585 586 587 588 589 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report