MAX9634 Evaluation Kit Evaluates: General Description Features
... The load current is measured as a voltage drop (VSENSE) across an external sense resistor. This voltage is then amplified by the current-sense amplifier and presented at the VOUT pad. Like all differential amplifiers, the output voltage has two components of error (an offset error and a gain error). ...
... The load current is measured as a voltage drop (VSENSE) across an external sense resistor. This voltage is then amplified by the current-sense amplifier and presented at the VOUT pad. Like all differential amplifiers, the output voltage has two components of error (an offset error and a gain error). ...
Because a Picture is Worth Billions of Photons
... All partial discharges then are current flows. In the case of corona discharge it is the current flow in air, from a discharge electrode under high voltage. High voltages cause air ionization and creates a plasma around the electrode. A plasma is a region of ionized matter, sometimes described as a ...
... All partial discharges then are current flows. In the case of corona discharge it is the current flow in air, from a discharge electrode under high voltage. High voltages cause air ionization and creates a plasma around the electrode. A plasma is a region of ionized matter, sometimes described as a ...
Document
... and lower THD. This paper has presented a novel PWM switching scheme for the proposed multilevel inverter. It utilizes three reference signals and a triangular carrier signal to generate PWM switching signals. The behavior of the proposed multilevel inverter was analyzed in detail. By controlling th ...
... and lower THD. This paper has presented a novel PWM switching scheme for the proposed multilevel inverter. It utilizes three reference signals and a triangular carrier signal to generate PWM switching signals. The behavior of the proposed multilevel inverter was analyzed in detail. By controlling th ...
Introduction to Circuit Analysis
... Use a meter scale with a maximum value higher than the quantity you are measuring. If you do not have a good idea of what the quantity will be, start at the highest scale and work down until you have a good measurement. Some meters have autoscaling, which is a convenient feature that does this autom ...
... Use a meter scale with a maximum value higher than the quantity you are measuring. If you do not have a good idea of what the quantity will be, start at the highest scale and work down until you have a good measurement. Some meters have autoscaling, which is a convenient feature that does this autom ...
Load, Switch, and Commutation Considerations
... loads include electrical machines, transformers, solenoids, and relays. High-current in-rush occurs with loads such as incandescent lamps, pulse-forming networks, snubbers, and motors. Incandescent lamps are essentially resistive, but the cold resistive in-rush current during turn-on is 12 to 18 tim ...
... loads include electrical machines, transformers, solenoids, and relays. High-current in-rush occurs with loads such as incandescent lamps, pulse-forming networks, snubbers, and motors. Incandescent lamps are essentially resistive, but the cold resistive in-rush current during turn-on is 12 to 18 tim ...
CSSJournals_ManuscriptPreparationGuidelines
... input of the microcontroller by using a potentiometer. The output voltage of the tachogenerator is scaled to 5V as the microcontroller ADC inputs are 5V supported. As earlier a range of voltages are set for the fixed duty cycle, so when the new value of voltage will be sensed by the microcontroller ...
... input of the microcontroller by using a potentiometer. The output voltage of the tachogenerator is scaled to 5V as the microcontroller ADC inputs are 5V supported. As earlier a range of voltages are set for the fixed duty cycle, so when the new value of voltage will be sensed by the microcontroller ...
MAX16814 Integrated, 4-Channel, High-Brightness LED Driver with High-Voltage DC-DC Controller EVALUATION KIT AVAILABLE
... The MAX16814 consists of four identical linear current source channels to drive four strings of HB LEDs. The channel current is adjustable from 20mA to 150mA with an accuracy of ±3% using an external resistor. The external resistor sets all 4-channel currents to the same value. The device allows con ...
... The MAX16814 consists of four identical linear current source channels to drive four strings of HB LEDs. The channel current is adjustable from 20mA to 150mA with an accuracy of ±3% using an external resistor. The external resistor sets all 4-channel currents to the same value. The device allows con ...
AN51 - Power Conditioning for Notebook and Palmtop Systems
... C4 forms the dominant loop pole with a loop zero added by R1. C5 forms a higher frequency loop pole to control switching ripple at the VC pin. A floating 5V power supply for the switcher is generated by D2 and C3 which peak detect the output voltage during switch “off” time. This is a very efficient ...
... C4 forms the dominant loop pole with a loop zero added by R1. C5 forms a higher frequency loop pole to control switching ripple at the VC pin. A floating 5V power supply for the switcher is generated by D2 and C3 which peak detect the output voltage during switch “off” time. This is a very efficient ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.4, pp. 1850-1855
... Whenever a fault occurs, the protective devices will disconnect power sources from multilevel inverter system. Downtime of manufacturing equipment results in huge loss. Many engineers and researchers have focused on incipient fault detection and preventive maintenance to avoid inverter and motor fau ...
... Whenever a fault occurs, the protective devices will disconnect power sources from multilevel inverter system. Downtime of manufacturing equipment results in huge loss. Many engineers and researchers have focused on incipient fault detection and preventive maintenance to avoid inverter and motor fau ...
a 750 MHz, 3.8 mA 10 ns Switching Multiplexers AD8180/AD8182*
... The AD8180 and AD8182 video multiplexers are designed for fast-switching (10 ns) and wide bandwidth (> 750 MHz). This performance is attained with low power dissipation (3.8 mA per active channel) through the use of proprietary circuit techniques and a dielectrically-isolated complementary bipolar p ...
... The AD8180 and AD8182 video multiplexers are designed for fast-switching (10 ns) and wide bandwidth (> 750 MHz). This performance is attained with low power dissipation (3.8 mA per active channel) through the use of proprietary circuit techniques and a dielectrically-isolated complementary bipolar p ...
A Three Phase Based Four Switch Inverter for Renewable Energy
... Micro grid research has gained prime interest in the domain of power system research due to the reduced consumption of fossil fuel. Renewable energy is also penetrating into modern power grids to reduce the global carbon footprints. Three phase micro grids are receiving significant importance in the ...
... Micro grid research has gained prime interest in the domain of power system research due to the reduced consumption of fossil fuel. Renewable energy is also penetrating into modern power grids to reduce the global carbon footprints. Three phase micro grids are receiving significant importance in the ...
DEVELOPMENT OF AN AUDIO EVOKED RESPONSE SYSTEM TO FACILITATE ANAESTHESIA MONITORING
... means, Standard deviations, RMS value and integrals of these FFT values were then obtained. Then ratios of each of these values obtained for the above two frequency ranges were computed for all the data sets (20 each). Subjecting the results through statistical T-tests, it was found that the ratio o ...
... means, Standard deviations, RMS value and integrals of these FFT values were then obtained. Then ratios of each of these values obtained for the above two frequency ranges were computed for all the data sets (20 each). Subjecting the results through statistical T-tests, it was found that the ratio o ...
TSM104W TSM104WA QUAD OPERATIONAL AMPLIFIER AND PROGRAMMABLE VOLTAGE REFERENCE
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
Functional Specifications
... This document is intended for the faculty and senior Electrical Engineering students of the School of Engineering at the University of Portland, as well as the industry representative overseeing this project. A general introduction to fluorescent lights and electronic ballasts is first presented in ...
... This document is intended for the faculty and senior Electrical Engineering students of the School of Engineering at the University of Portland, as well as the industry representative overseeing this project. A general introduction to fluorescent lights and electronic ballasts is first presented in ...
Band Gap
... speed. Due to large amount of digital data we will design serializer and phased locked loop. • We would like to take part in January MPW run. ...
... speed. Due to large amount of digital data we will design serializer and phased locked loop. • We would like to take part in January MPW run. ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.