• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
kk010 - installing of generator protection2009-08
kk010 - installing of generator protection2009-08

... 2. Overload on a small lapse of time that short should not cause the equipment to work. 3. Protection must be working, even though the overload occurs a small but long enough so that they can cause overheating in the series conveyor. ...
Design and construction of a polygon
Design and construction of a polygon

... implemented in a voltage source inverter which is mostly fed from the six-pulse diode bridge rectifier. Insulated gate bipolar transistors (IGBT’s) are employed as the VSI switches. The most important drawback of the six-pulse diode-bridge rectifier is its poor power factor injection of current harm ...
3.4 Metering Functions
3.4 Metering Functions

... The motor and energy management system shall consist of a Current/Voltage Measurement Module and a Main CPU Module. The motor and energy managements system shall have a current operating range of 0.1 and 2000 amperes. The motor and energy management system shall provide current, voltage, power and t ...
Aalborg Universitet Distributed Active Synchronization Strategy for Microgrid Seamless Reconnection to
Aalborg Universitet Distributed Active Synchronization Strategy for Microgrid Seamless Reconnection to

... DR units and dispersed loads, which can operate in both gridconnected and islanded modes [1]. In order to guarantee uninterruptible and reliable power supply, a smooth transition from islanded to grid-connected modes is required. To achieve this goal, it is necessary to synchronize microgrid voltage ...
EVB-EN5367QI User Guide
EVB-EN5367QI User Guide

C706 Alternator Troubleshooting Guide
C706 Alternator Troubleshooting Guide

Week 13-14-Transf-SAB2032
Week 13-14-Transf-SAB2032

RA01L9595M 数据资料DataSheet下载
RA01L9595M 数据资料DataSheet下载

... effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, w ...
Testing Application Notes
Testing Application Notes

... When the CT’s are mounted on the transformer primary windings, the user needs to install jumpers on the secondary windings to eliminate the Turns-Ratio reading errors Typical CT’s on the Delta windings is shown here Secondary windings are shorted (X bushings are shorted) ...
±5V, 250mA Dual Output Power Supply (Rev. A)
±5V, 250mA Dual Output Power Supply (Rev. A)

... 8.3.1.1 Switching Frequency (VPOS) The boost converter switching frequency may vary slightly as the operating conditions change, but is typically around 1.7 MHz for most operating conditions. 8.3.1.2 Output Voltage (VPOS) The boost converter's output voltage is factory-programmed to 5.0 V ±1.0% and ...
LTC6360 - Very Low Noise Single-Ended SAR ADC Driver with True Zero Output
LTC6360 - Very Low Noise Single-Ended SAR ADC Driver with True Zero Output

... The LTC6360 is a low noise amplifier suitable for driving single-ended high performance successive approximation register (SAR) ADCs. The LTC6360 uses a single amplifier with negative charge pump topology as shown in the Block Diagram. The output can swing from –0.48V to 4.91V. The amplifier is desi ...
MAX1637 Miniature, Low-Voltage, Precision Step-Down Controller General Description
MAX1637 Miniature, Low-Voltage, Precision Step-Down Controller General Description

... (SMPS) controller designed primarily for buck-topology regulators in battery-powered applications where high efficiency and low quiescent supply current are critical. Light-load efficiency is enhanced by automatic idlemode operation—a variable-frequency, pulse-skipping mode that reduces transition a ...
Insulation coordination studies
Insulation coordination studies

... serves as a basis for the actual overvoltage calculations. Based on the possible operating scenarios, a number of simulation cases are defined, differing among others in aspects like switching topology (e.g. normal operation or operating with contingencies), operating point (e.g. underexcited versus ...
APEJ-2014-06-0438
APEJ-2014-06-0438

MAX16936 36V, 220kHz to 2.2MHz Step-Down Converter with 28µA Quiescent Current General Description
MAX16936 36V, 220kHz to 2.2MHz Step-Down Converter with 28µA Quiescent Current General Description

... The MAX16936 is a 2.5A current-mode step-down converter with integrated high-side and low-side MOSFETs designed to operate with an external Schottky diode for better efficiency. The low-side MOSFET enables fixed-frequency forced-PWM (FPWM) operation under light-load applications. The device operates ...
Problems With Assistance, Module 4, Problem 1
Problems With Assistance, Module 4, Problem 1

... © Brooks/Cole Publishing Co. ...
VCM TCM LCM Data Sheet/Manual PDF
VCM TCM LCM Data Sheet/Manual PDF

... VAC Triac outputs. Due to protective suppression circuits connected in parallel with Triacs, these outputs have a high OFF-State Leakage current, which, if unloaded, is sufficient to keep a VCM in the ON condition continuously. The TCM incorporates a current bias that offsets output leakage currents ...
Find the Right Fuse!
Find the Right Fuse!

three-phase bridge rectifiers (b6)
three-phase bridge rectifiers (b6)

... the three-phase midpoint rectifier (M3). An additional investment in power devices and in the control circuits is justified if we take into account the M3 rectifier disadvantages and the advantages of the full bridge rectifiers. 2. Three-phase bridge rectifier (B6) with current filter In most applic ...
FDMS3615S  PowerTrench Power Stage
FDMS3615S PowerTrench Power Stage

... part to operate well within the breakdown voltage limits. This eliminates the need to have an external snubber circuit in most cases. If the designer chooses to use an RC snubber, it should be placed close to the part between the PHASE pad and S2 pins to dampen the high-frequency ringing. 5. The dri ...
General Specification for ION7350 Power Meter : msword
General Specification for ION7350 Power Meter : msword

... o Can record any parameter, either measured or derived. o Enabled and triggered manually or through internal operating conditions, including periodic timer or setpoint activity. o The number of records (depth) of each data recorder, and the overflow conditions (stop-when-full or circular) is program ...
MAX15023 Wide 4.5V to 28V Input, Dual-Output Synchronous Buck Controller General Description
MAX15023 Wide 4.5V to 28V Input, Dual-Output Synchronous Buck Controller General Description

... The MAX15023’s adaptive synchronous rectification eliminates the need for external freewheeling Schottky diodes. The device also utilizes the external low-side MOSFET’s on-resistance as a current-sense element, eliminating the need for a current-sense resistor. This protects the DCDC components from ...
HOW TO SPECIFY THE OPTIMUM NON-GAPPED LINE ARRESTERS (NGLA)
HOW TO SPECIFY THE OPTIMUM NON-GAPPED LINE ARRESTERS (NGLA)

NCP5006 Compact Backlight LED Boost Driver
NCP5006 Compact Backlight LED Boost Driver

... This pin is the power side of the external inductor and must be connected to the external Schottky diode. It provides the output current to the load. Since the boost converter operates in a current loop mode, the output voltage can range up to +24 V but shall not extend this limit. However, if the v ...
Al-Balqa` Applied University Faculty of Engineering Technology
Al-Balqa` Applied University Faculty of Engineering Technology

... 1-Connect the motor electrical power circuit 2- Set the stator windings voltage to nominal value, V1LN  400V 3- Set the rotor windings added resistance to zero, R 2ad 0  4- For different values of load torque fill the following table: Star connection of stator windings V1LN  400V , ...
< 1 ... 424 425 426 427 428 429 430 431 432 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report