CMOS Micromechanical Resonator Oscillator
... Oscillation builds up until either some form of nonlinearity or a designed automatic-level control circuit limits the amplitude. For oscillators controlled by quartz crystals, the nonlinearity usually appears in the sustaining circuit, where transistors enter the triode region at large voltage ampli ...
... Oscillation builds up until either some form of nonlinearity or a designed automatic-level control circuit limits the amplitude. For oscillators controlled by quartz crystals, the nonlinearity usually appears in the sustaining circuit, where transistors enter the triode region at large voltage ampli ...
Single-output and dual-output power supplies TOE 8840 – up to 160
... reliable and precise adjustment of the output voltage and current even after many years of service. ...
... reliable and precise adjustment of the output voltage and current even after many years of service. ...
Technologies for Seventh Generation High Performance, High Ruggedness Power Chips
... and newly optimized profiles in the backside doping layer. 1. Seventh generation IGBT The first to third generation IGBTs were of the planar type structure, and their performance was improved by applying the conventional finer cell-pitch patterning technology. The fourth and later generations adopte ...
... and newly optimized profiles in the backside doping layer. 1. Seventh generation IGBT The first to third generation IGBTs were of the planar type structure, and their performance was improved by applying the conventional finer cell-pitch patterning technology. The fourth and later generations adopte ...
HYDRA-X10 User Manual - Active-Semi
... Copyright © 2012-2013 Active-Semi, Inc. All rights reserved. All information provided in this document is subject to legal disclaimers. Active-Semi reserves the right to modify its products, circuitry or product specifications without notice. Active-Semi products are not intended, designed, warrante ...
... Copyright © 2012-2013 Active-Semi, Inc. All rights reserved. All information provided in this document is subject to legal disclaimers. Active-Semi reserves the right to modify its products, circuitry or product specifications without notice. Active-Semi products are not intended, designed, warrante ...
DRV135 数据资料 dataSheet 下载
... A driver/receiver balanced-pair (such as the DRV134 and INA137) rejects the voltage differences between the grounds at each end of the cable, which can be caused by ground currents, supply variations, etc. In addition to proper bypassing, the suggestions below should be followed to achieve optimal O ...
... A driver/receiver balanced-pair (such as the DRV134 and INA137) rejects the voltage differences between the grounds at each end of the cable, which can be caused by ground currents, supply variations, etc. In addition to proper bypassing, the suggestions below should be followed to achieve optimal O ...
adj5034 - Arecibo Observatory
... Each input and output module has an "enable" jumper on its (narrow) top side. If this jumper is plugged in, the module can (and must) be electrically enabled/disabled by applying resp. voltages to the +F/-F lines. This function is not used for this application. The enable jumper must be removed. ...
... Each input and output module has an "enable" jumper on its (narrow) top side. If this jumper is plugged in, the module can (and must) be electrically enabled/disabled by applying resp. voltages to the +F/-F lines. This function is not used for this application. The enable jumper must be removed. ...
Battery Cabinet Hardware v1.0 Author: Pierluigi Sarti, Technical Lead, Power
... be lowered accordingly so as to not exceed the C/5 recharge current. Circuit breakers with updated ratings can be replaced accordingly. • By instituting a (4+1) redundancy scheme. One battery string is used only in the event of battery failure elsewhere in the cabinet. Higher power levels can be ach ...
... be lowered accordingly so as to not exceed the C/5 recharge current. Circuit breakers with updated ratings can be replaced accordingly. • By instituting a (4+1) redundancy scheme. One battery string is used only in the event of battery failure elsewhere in the cabinet. Higher power levels can be ach ...
P84394
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
MC33811, Solenoid Monitor Integrated Circuit
... The Solenoid Monitor Input is connected to the solenoid coil at the output driver. It monitors the current waveform through the solenoid coil as it appears as a voltage across the output driver MOSFET. ...
... The Solenoid Monitor Input is connected to the solenoid coil at the output driver. It monitors the current waveform through the solenoid coil as it appears as a voltage across the output driver MOSFET. ...
Optimal placement of shunt connected facts device in a series long
... voltages (10 kV to 800 kV). The distribution networks generally operate below 100 kV while the bulk power is transmitted at higher voltages. The lines operating at different voltages are connected through transformers which operate at high efficiency. Traditionally, AC lines have no provision for th ...
... voltages (10 kV to 800 kV). The distribution networks generally operate below 100 kV while the bulk power is transmitted at higher voltages. The lines operating at different voltages are connected through transformers which operate at high efficiency. Traditionally, AC lines have no provision for th ...
64WKS_Installation_en-UK_RevA
... If necessary, up to three devices can be connected in parallel to boost performance, with one master taking over control and synchronization. This device enables the generation of a highly dynamic speed or torque/current control circuit. The actual speed is measured either by the electronic rectific ...
... If necessary, up to three devices can be connected in parallel to boost performance, with one master taking over control and synchronization. This device enables the generation of a highly dynamic speed or torque/current control circuit. The actual speed is measured either by the electronic rectific ...
- Nottingham ePrints
... as 60%. This characteristic makes the matrix converter a suitable topology for specific applications such as wind-diesel topologies, distributed generation applications, emergency vehicles, military and aerospace applications, external elevators for building construction and skin pass mills [2], [7] ...
... as 60%. This characteristic makes the matrix converter a suitable topology for specific applications such as wind-diesel topologies, distributed generation applications, emergency vehicles, military and aerospace applications, external elevators for building construction and skin pass mills [2], [7] ...
Universal Input Dual Lamp Ballast Parallel Configuration
... Our simplified critical conduction mode power factor control circuitry has only four pins: VBUS which senses the output voltage from the PFC boost converter, COMP which is the error amplifier compensation pin, ZX which senses the inductor current and PFC which is the PFC FET gate driver. No current ...
... Our simplified critical conduction mode power factor control circuitry has only four pins: VBUS which senses the output voltage from the PFC boost converter, COMP which is the error amplifier compensation pin, ZX which senses the inductor current and PFC which is the PFC FET gate driver. No current ...
Performance Optimization of Induction Motors During Voltage
... keep the current constant at the preset value during starting period. Current in the third line can be deduced from the two signals by the C. These will then be used for protection purposes against overload, unbalanced operation, and faults. The three line-to-line voltage signals are used only for z ...
... keep the current constant at the preset value during starting period. Current in the third line can be deduced from the two signals by the C. These will then be used for protection purposes against overload, unbalanced operation, and faults. The three line-to-line voltage signals are used only for z ...
Fault Identification in a Radial Power System Using Fuzzy Logic
... the faults must be detected very quickly in order to start necessary actions as soon as possible and isolate the faulted parts of the system so that the outages are prevented or minimized. The reliability of a power system is based upon its continuity while in operation. The continuity depends on pr ...
... the faults must be detected very quickly in order to start necessary actions as soon as possible and isolate the faulted parts of the system so that the outages are prevented or minimized. The reliability of a power system is based upon its continuity while in operation. The continuity depends on pr ...
BDTIC www.BDTIC.com/infineon ICB2FL02G
... LSGD (Low-side Gate drive, Pin 2) The Gate of the low-side MOSFET in a halfbridge inverter topology is controlled by this pin. There is an active L-level during UVLO (under voltage lockout) and a limitation of the max Hlevel at 11.0 V during normal operation. In order to turn-on the MOSFET softly (w ...
... LSGD (Low-side Gate drive, Pin 2) The Gate of the low-side MOSFET in a halfbridge inverter topology is controlled by this pin. There is an active L-level during UVLO (under voltage lockout) and a limitation of the max Hlevel at 11.0 V during normal operation. In order to turn-on the MOSFET softly (w ...
High Brightness LED Controller using the MC9RS08KA2
... A fixed frequency step-down (buck) DC to DC converter is implemented with the KA2 for usage in high brightness LED driving applications. The KA2 consists of all active functions required to directly implement a step-down converter with a minimum number of external components. The KA2 enables control ...
... A fixed frequency step-down (buck) DC to DC converter is implemented with the KA2 for usage in high brightness LED driving applications. The KA2 consists of all active functions required to directly implement a step-down converter with a minimum number of external components. The KA2 enables control ...
RF5626 Proposed
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
DAC7613 - Texas Instruments
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
... TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous mater ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.