• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet Fundamental impedance identification method for grid-connected voltage source inverters
Aalborg Universitet Fundamental impedance identification method for grid-connected voltage source inverters

... improve the transient and steady-state performance of the systems. Basing on the above analysis, we can denote that line fundamental impedance, together with several modified strategies such as droop control, virtual active and reactive power frame transformation [17,18,19], and adaptive droop coeff ...
1 AP240E Data Analysis Program Bulletin CW-E
1 AP240E Data Analysis Program Bulletin CW-E

... time due to the occurrence of a large inrush current, for example, when a motor is started. Voltage increases instantaneously, for example, when lightning occurs or when a power line with a heavy load is turned ON/OFF. Power supply is stopped instantaneously or for a short/long time, for example, wh ...
Specification Sheet
Specification Sheet

... Low voltage cut-off prevents battery damage and ensures positive charge acceptance following an extensive discharge ...
Pdf - Text of NPTEL IIT Video Lectures
Pdf - Text of NPTEL IIT Video Lectures

... the inter polar region 0 the other will be at 2 pi by p, but the number of coils connected in series between these two brushes will be 2 pi by a, where a is the number of parallel paths. So, 2 pi by a e c d theta, e c which is equal to 2 omega n z by 4 pi integral 0 to 2 pi by a B r l d theta. Now, ...
How to correctly Phase Bulova Accutrons for
How to correctly Phase Bulova Accutrons for

High Efficiency, Versatile Bidirectional Power Converter for Energy
High Efficiency, Versatile Bidirectional Power Converter for Energy

Loop Calibration and Maintenance with a Fluke Loop Calibrator
Loop Calibration and Maintenance with a Fluke Loop Calibrator

... signal conditioners Fluke loop calibrators are ideal for calibrating many 4-20 mA signal conditioners using their precision current sourcing and simulation capabilities. However, there are many signal conditioners that require a precision voltage source for proper calibration. Using a simple precisi ...
R.P. Pilawa-Podgurski, W. Li, I. Celanovic and D.J. Perreault, “Integrated CMOS Energy Harvesting Converter with Digital Maximum Power Point Tracking for a Portable Thermophotovoltaic Power Generator,” IEEE Journal of Emerging and Selected Topics in Power Electronics , Vol. 3, No. 4, pp. 1021-1035, August 2015.
R.P. Pilawa-Podgurski, W. Li, I. Celanovic and D.J. Perreault, “Integrated CMOS Energy Harvesting Converter with Digital Maximum Power Point Tracking for a Portable Thermophotovoltaic Power Generator,” IEEE Journal of Emerging and Selected Topics in Power Electronics , Vol. 3, No. 4, pp. 1021-1035, August 2015.

... converter. Moreover, since our proposed MPPT converter provides maximization of its input power, there is no inadvertent coupling between parallel MPPT converters. The shared output battery shown in Figure 3c further mitigates any such concerns, as it acts as a large (shared) fixed output voltage fo ...
AD421: Loop-Powered 4-20 mA DAC Data Sheet
AD421: Loop-Powered 4-20 mA DAC Data Sheet

... 0.01 µF to VCC, the regulated voltage is nominally 3.3 V. With LV connected to VCC the regulated voltage, VCC, is 3 V nominal. DAC Latch Input. Logic Input. A rising edge of the LATCH signal loads the data from the serial input shift register to the DAC latch and hence updates the output of the DAC. ...
CAS-FEST 2010: Mitigating Variability in Near
CAS-FEST 2010: Mitigating Variability in Near

... improved by more aggressive pipelining. Therefore, this technique is mostly used for the designs with relaxed performance constraints such as sensing systems [6], [8]. One potential solution to address delay variability while minimizing performance overhead is to use a type of soft-edge flip-flop (S ...
Electronics (2001)
Electronics (2001)

... • The first diode in the previous Figure is a semiconductor diode which could be a small signal diode. Notice the straight bar end has the letter “k”, this denotes the “cathode” while the “a” denotes anode. • Current only flows from anode to cathode and not in the reverse direction, hence the “arrow ...
Manual - MultiPlus 3k with 50A transfer switch 120V
Manual - MultiPlus 3k with 50A transfer switch 120V

... protection is damaged, the product should be taken out of operation and prevented from accidentally being put into operation again; contact qualified maintenance personnel. Ensure that the connection cables are provided with fuses and circuit breakers. Never replace a protective device by a componen ...
SN65LVDS116 数据资料 dataSheet 下载
SN65LVDS116 数据资料 dataSheet 下载

... output logic state can be indeterminate when the differential input voltage is between –100 mV and 100 mV and within its recommended input common-mode voltage range. Hovever, TI LVDS receivers handle the open-input circuit situation differently. Open-circuit means that there is little or no input cu ...
LTC3892/ - 60V Low IQ, Dual, 2-Phase Synchronous Step
LTC3892/ - 60V Low IQ, Dual, 2-Phase Synchronous Step

... VFB1,2. The specification at 85°C is not tested in production and is assured by design, characterization and correlation to production testing at other temperatures (125°C for the LTC3892E/LTC3892E-1/LTC3892E-2 and LTC3892I/LTC3892I-1/LTC3892I-2, 150°C for the LTC3892H/LTC3892H-1/ LTC3892H-2 and LTC ...
OSHA Published First-Ever Arc Flash Protection
OSHA Published First-Ever Arc Flash Protection

... Safety in the Workplace®, were designed to reduce exposure to the hazards of shock, electrocution, arc flash, and arc blast while working on or near exposed electrical conductors or circuit parts that are or become energized. ...
MAX1515 Low-Voltage, Internal Switch, Step-Down/DDR Regulator General Description
MAX1515 Low-Voltage, Internal Switch, Step-Down/DDR Regulator General Description

... supply rail. The input of the power stage can be taken from the memory supply rail itself, resulting in an efficient power supply that returns the energy to the rail from which it was sourced. The MAX1515 includes a reference buffer that provides ±5mA of drive current. The MAX1515 uses a unique curr ...
So far, we have only considered DC analysis and only resistive drops
So far, we have only considered DC analysis and only resistive drops

LM5360x-Q1 5-V, 3.3-V, and Adjustable Synchronous-Buck 1
LM5360x-Q1 5-V, 3.3-V, and Adjustable Synchronous-Buck 1

... applications, providing an output voltage of 5 V, 3.3 V, or an adjustable output. Load current up to 650 mA is supported by the LM53600-Q1, while the LM53601-Q1 supports up to 1000 mA. Advanced high-speed circuitry allows the LM53600-Q1 and LM53601-Q1 devices to regulate from an input of 18 V to an ...
lighting control by strand electric
lighting control by strand electric

... voltage once more. However the thyristor is what is known as a controlled rectifier and regulation can be applied to the pair from a small dimmer lever in such a way that each passes less and less of its half cycle. In consequence the voltage averages at less and less until stopped off compl etely. ...
Waveform Relaxation Techniques for Simulation of Coupled
Waveform Relaxation Techniques for Simulation of Coupled

Load Surge Management
Load Surge Management

... ● Fault tolerant circuitry relies on two critical features ● Inverter is fast enough to current limit (switch off) and avoid being overloaded by excessive fault currents ● Static transfer switch can sustain enough current to clear the fault without damage ...
Millimetre Wave Generator G4-143g
Millimetre Wave Generator G4-143g

... Oscillator unit is made up of BWO and high voltage isolator. BWO intended to generate UHF oscillations. High voltage isolator intended to isolate the BWO’s cabinet being kept under high voltage, from grounded output waveguide. Control unit is based on PC microcomputer. It is used together with digit ...
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.

... be traced to the large armature synchronous inductances of the Lundell machine. Significant voltage drops occur across the synchronous inductances when current is drawn from the machine, and these drops increase with increasing output current and operating speed. Consequently, the Lundell alternator ...
Installation Testing Power
Installation Testing Power

... Section A of TP 76900MP shall be used in conjunction with this Section P. ...
High Voltage Ceramic Capacitors
High Voltage Ceramic Capacitors

... Each lead wire should be subjected to 5N of weight and bent 90˚ at the point of egress, in one direciton, then returned to its original position and bent 90˚ in the opposite direction at the rate of one bend in 2 to 3 sec. The lead wire of a capacitor should be dipped into a 25% methanol solution of ...
< 1 ... 320 321 322 323 324 325 326 327 328 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report