ECE 431 Electric Machines Lab Manual
... 2. Safety ......................................................................................................................................... 6 2.1 Safety Precautions ............................................................................................................. 6 2.2 Summary of ...
... 2. Safety ......................................................................................................................................... 6 2.1 Safety Precautions ............................................................................................................. 6 2.2 Summary of ...
MAX17502 60V, 1A, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
... The device uses a peak-current-mode control scheme. An internal transconductance error amplifier generates an integrated error voltage. The error voltage sets the duty cycle using a PWM comparator, a high-side current-sense amplifier, and a slope-compensation generator. At each rising edge of the cl ...
INSTALLATION INSTRUCTIONS - Macromatic Industrial Controls
... independently selectable & adjustable ON & OFF times. Switches C & D are used to select the time range for t1. Switches E & F are used to select the time range for t2. Using the table above, set Switches C, D, E & F to ON or THR-3856U only OFF to select the time range for t1 & t2. Then adjust within ...
... independently selectable & adjustable ON & OFF times. Switches C & D are used to select the time range for t1. Switches E & F are used to select the time range for t2. Using the table above, set Switches C, D, E & F to ON or THR-3856U only OFF to select the time range for t1 & t2. Then adjust within ...
DMN65D8LDW Product Summary Features
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
M5100-EX Instructions
... More detailed information is available at www.panamax.com If you have any questions regarding these requirements, please contact Panamax Customer Relations ...
... More detailed information is available at www.panamax.com If you have any questions regarding these requirements, please contact Panamax Customer Relations ...
LMH6551 Differential, High Speed Op Amp
... mode as well as driving the V+ and V− outputs to be equal magnitude and opposite phase, even when only one of the two input channels is driven. The common mode feedback circuit allows single ended to differential operation. The LMH6551 is a voltage feedback amplifier with gain set by external resist ...
... mode as well as driving the V+ and V− outputs to be equal magnitude and opposite phase, even when only one of the two input channels is driven. The common mode feedback circuit allows single ended to differential operation. The LMH6551 is a voltage feedback amplifier with gain set by external resist ...
MART-02:
... Consecutive record by message linking method Messages are recorded consecutively from the beginning of memory; they compose an entirety which, when playback, is treated as a single record. • Apply H-level voltage to address inputs A1, A4, A6 and A7; the remaining address inputs to be at L-level volt ...
... Consecutive record by message linking method Messages are recorded consecutively from the beginning of memory; they compose an entirety which, when playback, is treated as a single record. • Apply H-level voltage to address inputs A1, A4, A6 and A7; the remaining address inputs to be at L-level volt ...
Link to pdf of brochure on Lithium Batteries for Automotive
... The TLM-battery is very safe due to the chemical system and internal composition. The anode is far from being as reactive as the lithium metal usually used in nonrechargeable lithium batteries. The electrolyte is moderately flammable. The battery develops less heat if it is short-circuited and there ...
... The TLM-battery is very safe due to the chemical system and internal composition. The anode is far from being as reactive as the lithium metal usually used in nonrechargeable lithium batteries. The electrolyte is moderately flammable. The battery develops less heat if it is short-circuited and there ...
Unit 39: Electrical Principles in Building Services
... Learners should clearly appreciate that each aspect and topic form a stage in the overall process of understanding the principle of how electricity works and its application and relevance to plant, equipment and machinery that is used in both the electrical and building engineering services sector. ...
... Learners should clearly appreciate that each aspect and topic form a stage in the overall process of understanding the principle of how electricity works and its application and relevance to plant, equipment and machinery that is used in both the electrical and building engineering services sector. ...
General Description Features
... the MAX1531 includes five linear regulator controllers for supplying logic and LCD bias voltages. A programmable startup sequence enables easy control of the regulators. The MAX1530/MAX1531 include soft-start functions to limit inrush current during startup. An internal stepdown converter current-li ...
... the MAX1531 includes five linear regulator controllers for supplying logic and LCD bias voltages. A programmable startup sequence enables easy control of the regulators. The MAX1530/MAX1531 include soft-start functions to limit inrush current during startup. An internal stepdown converter current-li ...
Complete ECE 112 Manual
... turned off, use only one hand when working on it. This will prevent a circuit from being going through your heart, which could be potentially fatal. ...
... turned off, use only one hand when working on it. This will prevent a circuit from being going through your heart, which could be potentially fatal. ...
MAX3388E/MAX3389E 2.5V, ±15kV ESD-Protected RS-232 Transceivers for PDAs and Cell Phones General Description
... The MAX3388E/MAX3389E are 2.5V-powered EIA/TIA232 and V.28/V.24 communications interfaces with low power requirements, high data-rate capabilities, and enhanced electrostatic discharge (ESD) protection. The MAX3388E/MAX3389E have two receivers and three transmitters. All RS-232 inputs and outputs ar ...
... The MAX3388E/MAX3389E are 2.5V-powered EIA/TIA232 and V.28/V.24 communications interfaces with low power requirements, high data-rate capabilities, and enhanced electrostatic discharge (ESD) protection. The MAX3388E/MAX3389E have two receivers and three transmitters. All RS-232 inputs and outputs ar ...
theory and technology of instrument transformers
... The purpose of instrument transformers is to reduce the voltage and current of an electrical network to a standardized non hazardous level. They prevent any direct connection between instruments and high voltage circuits which would be dangerous to operators and would need instrument panels with spe ...
... The purpose of instrument transformers is to reduce the voltage and current of an electrical network to a standardized non hazardous level. They prevent any direct connection between instruments and high voltage circuits which would be dangerous to operators and would need instrument panels with spe ...
P84233
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ra ...
TFT - Bahnhof
... Good sensitivity (contact imaging). Reduced resolution due to light scattering. Simpler structure and materials. ...
... Good sensitivity (contact imaging). Reduced resolution due to light scattering. Simpler structure and materials. ...
5 HP – 30 HP Single-Phase to Three
... digital phase converter for operating three-phase electrical equipment from a singlephase source. The converter shall deliver balanced, sine-wave voltages with high efficiency, electronic power factor correction and high momentary overload currents for starting motors. Protection from under-voltage ...
... digital phase converter for operating three-phase electrical equipment from a singlephase source. The converter shall deliver balanced, sine-wave voltages with high efficiency, electronic power factor correction and high momentary overload currents for starting motors. Protection from under-voltage ...
Microwave Generator For Scientific And Medical Applications
... Technical University of Cluj-Napoca, 28 Memorandumului, 400114, Cluj-Napoca, Romania Abstract. Nowadays power microwave radiation is widely used in medical applications as hyperthermia, diathermy or ablation and for scientific applications such as plasma generation, digestion, or as a catalyst in gr ...
... Technical University of Cluj-Napoca, 28 Memorandumului, 400114, Cluj-Napoca, Romania Abstract. Nowadays power microwave radiation is widely used in medical applications as hyperthermia, diathermy or ablation and for scientific applications such as plasma generation, digestion, or as a catalyst in gr ...
PDF
... and ground planes (i.e. the di/dt noise, also known as power /ground bounce). It is a critical and challenging design task to control the amount of inductive noise that is inserted into the power planes. Package pins, bonding wires, and on chip IC interconnections all have parasitic inductance. When ...
... and ground planes (i.e. the di/dt noise, also known as power /ground bounce). It is a critical and challenging design task to control the amount of inductive noise that is inserted into the power planes. Package pins, bonding wires, and on chip IC interconnections all have parasitic inductance. When ...
AND9408 - Basic Principles of LLC Resonant Half Bridge
... When Compared to fs=fr1, the waveforms of fs>fr1 are a little different. The major difference is that at heavy load, the resonant current is of higher magnitude than the magnetizing current when the high side or low side is turning−off. With this condition, when phase node switches high or low, the ...
... When Compared to fs=fr1, the waveforms of fs>fr1 are a little different. The major difference is that at heavy load, the resonant current is of higher magnitude than the magnetizing current when the high side or low side is turning−off. With this condition, when phase node switches high or low, the ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.