Bip Transistor 100V, 4A NPN TP/TP-FA
... Any and all SANYO Semiconductor Co.,Ltd. products described or contained herein are, with regard to "standard application", intended for the use as general electronics equipment. The products mentioned herein shall not be intended for use for any "special application" (medical equipment whose purpos ...
... Any and all SANYO Semiconductor Co.,Ltd. products described or contained herein are, with regard to "standard application", intended for the use as general electronics equipment. The products mentioned herein shall not be intended for use for any "special application" (medical equipment whose purpos ...
Specification for Impulse Voltage Generator
... Contractor supervision during installation. Indication must be stated regarding the delivery and installation time of equipment. Operating and maintenance manuals to be supplied with all equipment. OEM / Contractor to provide training of Rotek test staff to conduct impulse voltage testing, u ...
... Contractor supervision during installation. Indication must be stated regarding the delivery and installation time of equipment. Operating and maintenance manuals to be supplied with all equipment. OEM / Contractor to provide training of Rotek test staff to conduct impulse voltage testing, u ...
LT1784 - 2.5MHz, Over-The-Top Low Power, Rail-to-Rail Input and Output Op Amp in SOT-23
... unique feature of this device is its Over-The-Top® operation capabilitity with either or both of its inputs above the positive rail. The inputs handle 18V both differential and common mode, independent of supply voltage. The input stage incorporates phase reversal protection to prevent false outputs ...
... unique feature of this device is its Over-The-Top® operation capabilitity with either or both of its inputs above the positive rail. The inputs handle 18V both differential and common mode, independent of supply voltage. The input stage incorporates phase reversal protection to prevent false outputs ...
Variable Tap Transformer
... OLTCs (or voltage regulators) can be directly included in the power flow equations by modifying the Ybus entries; that is by scaling the terms by 1, 1/t or 1/t^2 as appropriate If t is fixed then there is no change in the number of equations If t is variable, such as to enforce a voltage equality, t ...
... OLTCs (or voltage regulators) can be directly included in the power flow equations by modifying the Ybus entries; that is by scaling the terms by 1, 1/t or 1/t^2 as appropriate If t is fixed then there is no change in the number of equations If t is variable, such as to enforce a voltage equality, t ...
Schottky diode I-V Characteristics
... • Typical metals used are molybdenum, platinum, chromium or tungsten; and the semiconductor would typically be N-type silicon. • The metal side acts as the anode and N-type semiconductor acts as the cathode of the diode. This Schottky barrier results in both very fast switching and low forward volta ...
... • Typical metals used are molybdenum, platinum, chromium or tungsten; and the semiconductor would typically be N-type silicon. • The metal side acts as the anode and N-type semiconductor acts as the cathode of the diode. This Schottky barrier results in both very fast switching and low forward volta ...
Series One Programmable Controllers Series One/One Plus User`s
... With Removable Terminal Board IC610MDLllZ ...
... With Removable Terminal Board IC610MDLllZ ...
FM50 - uri=media.digikey
... driving a P-channel load. Available current is typically 50μA to ground. Series resistance is typically 7kΩ, charging and 2kΩ, discharging through a capacitor connected from VOUT to ground. ...
... driving a P-channel load. Available current is typically 50μA to ground. Series resistance is typically 7kΩ, charging and 2kΩ, discharging through a capacitor connected from VOUT to ground. ...
Our low carbon challenge
... 10,000 days of good 10-minute data At transformer and head of each feeder, per phase + neutral Value of monitoring within LVNS ...
... 10,000 days of good 10-minute data At transformer and head of each feeder, per phase + neutral Value of monitoring within LVNS ...
Raychem Ground Fault Protection Devices Additional Reference
... number or a “W1” suffix to the Westinghouse part number (example: QOB120EPD2100 is a 20 A, 120 V breaker with bell alarm contacts). ...
... number or a “W1” suffix to the Westinghouse part number (example: QOB120EPD2100 is a 20 A, 120 V breaker with bell alarm contacts). ...
DFM600FXM18-A000
... This is the most tentative form of information and represents a very preliminary specification. No actual work on the product has been started. ...
... This is the most tentative form of information and represents a very preliminary specification. No actual work on the product has been started. ...
Fan Transfer Function Lab Report
... voltage sensitivity (Hz/V). For the Voltage Sweep Graphs, the linear increase in speed shows The labview program in use performs a controlled voltage sweep from 5 to 12 volts through the DC motors. At the same time the fan speed is measured by how often the connection path between the infrared LED a ...
... voltage sensitivity (Hz/V). For the Voltage Sweep Graphs, the linear increase in speed shows The labview program in use performs a controlled voltage sweep from 5 to 12 volts through the DC motors. At the same time the fan speed is measured by how often the connection path between the infrared LED a ...
Galaxy 5500
... latest load requirements that include upstream harmonics management for a generator-friendly installation and flexible configurations due to the wide range of integrated options and auxiliary equipment. Complete front access allows for a spacesaving footprint, user-friendly graphical display with mu ...
... latest load requirements that include upstream harmonics management for a generator-friendly installation and flexible configurations due to the wide range of integrated options and auxiliary equipment. Complete front access allows for a spacesaving footprint, user-friendly graphical display with mu ...
Phet Parallel Circui..
... 1. Drag and drop one light bulb and one battery in the work area. Drag and drop wires to connect the battery to the light bulb. Once the circuit is completed, the bulb should light and you should see the flow of charge from positive to negative end of the battery through the circuit. This is circuit ...
... 1. Drag and drop one light bulb and one battery in the work area. Drag and drop wires to connect the battery to the light bulb. Once the circuit is completed, the bulb should light and you should see the flow of charge from positive to negative end of the battery through the circuit. This is circuit ...
Description The FC-33 is a DIN rail mount, selectable input / output
... with 1500VDC isolation between input and output and 1500VDC isolation from 24 volt power and input / output. The field configurable input/output types allow a wide ranging capability for 0 - 5V , 0 - 10V , 0 - 20mA , 4 - 20mA . ...
... with 1500VDC isolation between input and output and 1500VDC isolation from 24 volt power and input / output. The field configurable input/output types allow a wide ranging capability for 0 - 5V , 0 - 10V , 0 - 20mA , 4 - 20mA . ...
TS1003 Demo Board
... assembled and tested circuit board that can be used for evaluating the TS1003. The TS1003 is the industry’s first sub-1µA supply current, precision CMOS operational amplifier fully specified to operate over a supply voltage range from 0.8V to 5.5V. Fully specified at 1.8V, the TS1003 is optimized fo ...
... assembled and tested circuit board that can be used for evaluating the TS1003. The TS1003 is the industry’s first sub-1µA supply current, precision CMOS operational amplifier fully specified to operate over a supply voltage range from 0.8V to 5.5V. Fully specified at 1.8V, the TS1003 is optimized fo ...
Typical Causes of Winding Failuresin Three-Phase
... Thermal deterioration of insulation in one phase of the stator winding can result from unequal voltage between phases. Unequal voltages usually are caused by unbalanced loads on the power source, a poor connection at the motor terminal, or a high resistance contact (weak spring). Note: A one-percent ...
... Thermal deterioration of insulation in one phase of the stator winding can result from unequal voltage between phases. Unequal voltages usually are caused by unbalanced loads on the power source, a poor connection at the motor terminal, or a high resistance contact (weak spring). Note: A one-percent ...
S03-Switching Transients Abstract
... transient interaction. It suggests mitigation techniques. Several examples are provided. ...
... transient interaction. It suggests mitigation techniques. Several examples are provided. ...
D1213A-04TS Features Mechanical Data
... Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Inc ...
... Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Inc ...
CURRENT HARMONICS GENERATED BY LAMPS: A COMPARISON IN Claudio Cicala
... the limits for harmonic current emissions for equipment with an input current up to and including 16 A in specified test conditions [1] and define the measuring techniques [2]. The limits on harmonic distortion of the test voltage [2] are much more restrictive than the limits allowed in public distr ...
... the limits for harmonic current emissions for equipment with an input current up to and including 16 A in specified test conditions [1] and define the measuring techniques [2]. The limits on harmonic distortion of the test voltage [2] are much more restrictive than the limits allowed in public distr ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.