SR2 Modules are designed for interconnection via CSInet which
... SR2 Distributed Network monitoring modules Remote power via PoE - reliable and redundant function modules - targeted monitoring Connect via CSInet or direct LAN connection for local monitoring Individual dedicated function modules are retrofitted/installed in power devices, HVAC, Fire Suppress ...
... SR2 Distributed Network monitoring modules Remote power via PoE - reliable and redundant function modules - targeted monitoring Connect via CSInet or direct LAN connection for local monitoring Individual dedicated function modules are retrofitted/installed in power devices, HVAC, Fire Suppress ...
Electrical Test Probe Station
... Figure 12. Data saving and CV measurement 16. The probe station is also capable of measuring capacitance as a function of biased voltage. The measurement setting can be selected from my favorite setup, the CVSweep (Figure 12). In the test parameters, input the measurement frequency (75 kHz to 30 MHz ...
... Figure 12. Data saving and CV measurement 16. The probe station is also capable of measuring capacitance as a function of biased voltage. The measurement setting can be selected from my favorite setup, the CVSweep (Figure 12). In the test parameters, input the measurement frequency (75 kHz to 30 MHz ...
Series and Parallel Resistors
... • To learn to connect components correctly according to a circuit diagram and then to make valid current and voltage measurements with ammeters and voltmeters. • To compare the predicted and measured currents and voltages for three circuits. ...
... • To learn to connect components correctly according to a circuit diagram and then to make valid current and voltage measurements with ammeters and voltmeters. • To compare the predicted and measured currents and voltages for three circuits. ...
DS1834/A/D Dual EconoReset with Pushbutton FEATURES PIN ASSIGNMENT
... All versions of the DS1834 can maintain valid outputs as long as one input remains above 1.2 volts. However, the RST outputs on the DS1834 use a push-pull output structure which can maintain a valid output below 1.2 volts. To sink current below 1.2 volts a resistor can be connected from RST to GND ( ...
... All versions of the DS1834 can maintain valid outputs as long as one input remains above 1.2 volts. However, the RST outputs on the DS1834 use a push-pull output structure which can maintain a valid output below 1.2 volts. To sink current below 1.2 volts a resistor can be connected from RST to GND ( ...
K - thermengr.com
... that this high current value produces sufficient slope variations from device-to-device to make calibration necessary on each individual diode, and that the calibration has to be repeated each time the current value changes. The Dual Current Method overcomes these issues by using separate currents f ...
... that this high current value produces sufficient slope variations from device-to-device to make calibration necessary on each individual diode, and that the calibration has to be repeated each time the current value changes. The Dual Current Method overcomes these issues by using separate currents f ...
VI-HAM™, VE-HAM
... Figure 10 — Required HAM filter, Vicor part # 30205 For applications using HAMD + BAMD or where the user desires to construct a custom HAM filter, the filter should be designed following Figure 10, the schematic of Vicor’s P/N 30205 filter. The current carrying capability of the inductors must be sc ...
... Figure 10 — Required HAM filter, Vicor part # 30205 For applications using HAMD + BAMD or where the user desires to construct a custom HAM filter, the filter should be designed following Figure 10, the schematic of Vicor’s P/N 30205 filter. The current carrying capability of the inductors must be sc ...
BDTIC www.BDTIC.com/infineon Industrial Power Control
... Advance Design System™ (ADS) of Agilent Technologies, AMBA™, ARM™, MULTI-ICE™, KEIL™, PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigatio ...
... Advance Design System™ (ADS) of Agilent Technologies, AMBA™, ARM™, MULTI-ICE™, KEIL™, PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigatio ...
Synchronous machine/Excitation system
... The operation of the excitation system begins with the peak detector, which computes the peak value of the fundamental component of both the voltage and current waveforms. This control is depicted in Figure 2. Therein, and throughout this work, variables of the form x and x̂ denote measured and esti ...
... The operation of the excitation system begins with the peak detector, which computes the peak value of the fundamental component of both the voltage and current waveforms. This control is depicted in Figure 2. Therein, and throughout this work, variables of the form x and x̂ denote measured and esti ...
NAS3XXX SMT Non-Isolated Point-of
... This NAS non-isolated point-of-load (POL) dc-dc converter delivers up to 9A current or 60W power in an industry standard SMT package with high efficiency and unparalleled thermal performance. The high input voltage allows it to be used in applications where traditionally isolated converter has to be ...
... This NAS non-isolated point-of-load (POL) dc-dc converter delivers up to 9A current or 60W power in an industry standard SMT package with high efficiency and unparalleled thermal performance. The high input voltage allows it to be used in applications where traditionally isolated converter has to be ...
2_marks_with_ans_fe28f - e
... If both the inputs are allowed to swing in both positive and negative directions, the operation is four quadrant multiplier operations. 7. In what way VCO is different from other oscillator (May/June 2012) Ans: 1.To adjust the output frequency to match (or perhaps be some exact multiple of) an accur ...
... If both the inputs are allowed to swing in both positive and negative directions, the operation is four quadrant multiplier operations. 7. In what way VCO is different from other oscillator (May/June 2012) Ans: 1.To adjust the output frequency to match (or perhaps be some exact multiple of) an accur ...
4-Channel, 1 MSPS, 12-Bit ADC with Sequencer in 16-Lead TSSOP AD7924-KGD
... the falling edge of CS and conversion is initiated at this point. There are no pipeline delays associated with the part. The AD7924-KGD uses advanced design techniques to achieve very low power dissipation at maximum throughput rates. At maximum throughput rates, the AD7924-KGD consumes 2 mA maximum ...
... the falling edge of CS and conversion is initiated at this point. There are no pipeline delays associated with the part. The AD7924-KGD uses advanced design techniques to achieve very low power dissipation at maximum throughput rates. At maximum throughput rates, the AD7924-KGD consumes 2 mA maximum ...
ELEC 120L Foundations of Electrical
... waves. The signal generated by a function generator is typically made available to the outside world via a coaxial cable connector, which consists of a center wire surrounded by insulation, which in turn is surrounded by a second metallic conductor, called a “shield.” As shown in the left-hand side ...
... waves. The signal generated by a function generator is typically made available to the outside world via a coaxial cable connector, which consists of a center wire surrounded by insulation, which in turn is surrounded by a second metallic conductor, called a “shield.” As shown in the left-hand side ...
MAX8710, MAX8711, MAX8712, MAX8761
... in LCD monitors and LCD TVs. All four devices include a high-performance AV DD linear regulator, a positive charge-pump regulator, a negative charge-pump regulator, and built-in power-up sequence control. The MAX8710/MAX8711/MAX8761 also include a high-current operational amplifier. Additionally, th ...
... in LCD monitors and LCD TVs. All four devices include a high-performance AV DD linear regulator, a positive charge-pump regulator, a negative charge-pump regulator, and built-in power-up sequence control. The MAX8710/MAX8711/MAX8761 also include a high-current operational amplifier. Additionally, th ...
Action PAK AP1690 ® AC Input, Field Configurable Limit Alarms
... reset only when the process falls below the HI deadband or rises above the low deadband (see figure 1). To reset a latched setpoint the signal must be in the safe region and the line power turned off for at least 5 seconds. For proper deadband operation, the HI setpoint must always be set above the ...
... reset only when the process falls below the HI deadband or rises above the low deadband (see figure 1). To reset a latched setpoint the signal must be in the safe region and the line power turned off for at least 5 seconds. For proper deadband operation, the HI setpoint must always be set above the ...
N-channel 900 V, 0.72 typ., 7 A MDmesh™ K5 Power MOSFET in a
... switching and diode recovery times ...
... switching and diode recovery times ...
IMPROVEMENT OF THD USING FUZZY LOGIC BASED PWM
... energy conversion modules. The matrix converter is an alternative to a inverter drive for a frequency control. The matrix converter is also known as an ‘all-silicon solution’. The matrix converter is a single stage converter which does not require any capacitor as the dc-link energy storage componen ...
... energy conversion modules. The matrix converter is an alternative to a inverter drive for a frequency control. The matrix converter is also known as an ‘all-silicon solution’. The matrix converter is a single stage converter which does not require any capacitor as the dc-link energy storage componen ...
Example Questions
... with gear gain Ng, which is the ratio of the velocity of shaft A to the velocity of shaft B. If the encoder is used to measure the angular position of shaft B, what is the angular displacement measurement resolution? If the encoder is used to measure the velocity of shaft B by counting the number of ...
... with gear gain Ng, which is the ratio of the velocity of shaft A to the velocity of shaft B. If the encoder is used to measure the angular position of shaft B, what is the angular displacement measurement resolution? If the encoder is used to measure the velocity of shaft B by counting the number of ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.