
Lokal fulltext - Chalmers tekniska högskola
... Oscillators (LOs), that can generate sufficient power to drive high frequency components. Conventional electronic, two terminal LOs are based on: impact-ionization avalanche transit-time (IMPATT) [6], and transferred-electron devices (TEDs) also known as Gunn diodes [7]. In the optical domain Quantu ...
... Oscillators (LOs), that can generate sufficient power to drive high frequency components. Conventional electronic, two terminal LOs are based on: impact-ionization avalanche transit-time (IMPATT) [6], and transferred-electron devices (TEDs) also known as Gunn diodes [7]. In the optical domain Quantu ...
attachment=3734
... machine gives rise to a steady temperature rise not exceeding the limit prescribed by the insulation class. Apart from the constant loss incurred in Alternators is the copper loss, occurring in the 3 -phase winding which depends on I2 R, the square of the current delivered by the generator. As the c ...
... machine gives rise to a steady temperature rise not exceeding the limit prescribed by the insulation class. Apart from the constant loss incurred in Alternators is the copper loss, occurring in the 3 -phase winding which depends on I2 R, the square of the current delivered by the generator. As the c ...
Dynamic Testing of Permanent Magnet Synchronous Machines
... (DTM). In contrast to traditional methods, the DTM tests machines without a brake or a locking mechanism for the test object's rotor. Instead, the moment of inertia of the rotor shaft limits the mechanical dynamics while a voltage source imposes torque producing currents on the stator windings of th ...
... (DTM). In contrast to traditional methods, the DTM tests machines without a brake or a locking mechanism for the test object's rotor. Instead, the moment of inertia of the rotor shaft limits the mechanical dynamics while a voltage source imposes torque producing currents on the stator windings of th ...
Kollmorgen S400 Servo Drive Manual
... Technical changes to improve the performance of the equipment may be made without notice ! Printed in the Federal Republic of Germany All rights reserved. No part of this work may be reproduced in any form (by photocopying, microfilm or any other method) or processed, copied or distributed by electr ...
... Technical changes to improve the performance of the equipment may be made without notice ! Printed in the Federal Republic of Germany All rights reserved. No part of this work may be reproduced in any form (by photocopying, microfilm or any other method) or processed, copied or distributed by electr ...
- IEEE Mentor
... appropriate, and are either single-phase or three-phase units. Because they are of tamper-resistant construction, they do not require fencing. Primary and secondary connections are made in compartments that are adjacent to each other but separated by barriers from the transformer and each other. Acc ...
... appropriate, and are either single-phase or three-phase units. Because they are of tamper-resistant construction, they do not require fencing. Primary and secondary connections are made in compartments that are adjacent to each other but separated by barriers from the transformer and each other. Acc ...
Chapter 6: Interfacing to Data Converters
... when the applied common-mode voltage changes, the amplifier input offset voltage and input bias current does also. In fact, when both current sources remain active throughout most of the entire input common-mode range, amplifier input offset voltage is the average offset voltage of the two pairs. In ...
... when the applied common-mode voltage changes, the amplifier input offset voltage and input bias current does also. In fact, when both current sources remain active throughout most of the entire input common-mode range, amplifier input offset voltage is the average offset voltage of the two pairs. In ...
Crompton Instruments Protector Trip Relays
... Allows direct connection from the SPR system protection relay to SCADA or PC based systems. ...
... Allows direct connection from the SPR system protection relay to SCADA or PC based systems. ...
medium-voltage switchgear
... AC control power shall be furnished from: [Pick one of the next two paragraphs. Delete the other. Then, make decisions within the remaining paragraph.] a. [An internally mounted dry-type transformer, including primary and secondary fuses. Control Power Transformer (CPT) shall be [15 kVA single phase ...
... AC control power shall be furnished from: [Pick one of the next two paragraphs. Delete the other. Then, make decisions within the remaining paragraph.] a. [An internally mounted dry-type transformer, including primary and secondary fuses. Control Power Transformer (CPT) shall be [15 kVA single phase ...
MAX5471/MAX5472/MAX5474/MAX5475 32-Tap, Nonvolatile, Linear-Taper Digital Potentiometers in SOT23 General Description
... potentiometer placed in standby without storing the latest wiper position. The factory-default wiper position is midscale. These devices can also be operated like a one-time programmable (OTP) device. Once the desired wiper position is trimmed and stored in nonvolatile memory, disable the serial int ...
... potentiometer placed in standby without storing the latest wiper position. The factory-default wiper position is midscale. These devices can also be operated like a one-time programmable (OTP) device. Once the desired wiper position is trimmed and stored in nonvolatile memory, disable the serial int ...
Product Data Sheet09/22/2015
... temperature-compensated linear in dB control voltage characteristic. This voltage controlled attenuator is controlled by a single positive control voltage with on chip DC conditioning circuitry. The slope polarity of the control voltage versus gain is selectable. The RFSA2033 draws a very low 2.5mA ...
... temperature-compensated linear in dB control voltage characteristic. This voltage controlled attenuator is controlled by a single positive control voltage with on chip DC conditioning circuitry. The slope polarity of the control voltage versus gain is selectable. The RFSA2033 draws a very low 2.5mA ...
SP334 数据资料DataSheet下载
... SP334CT-L........................................................................... 0°C to +70°C..............................................................................................28-pin WSOIC SP334CT-L/TR..................................................................... 0°C to +70°C.. ...
... SP334CT-L........................................................................... 0°C to +70°C..............................................................................................28-pin WSOIC SP334CT-L/TR..................................................................... 0°C to +70°C.. ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
... (2) The legal owner of a generating unit must determine the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value to determine the voltage ride through requirements for the genera ...
... (2) The legal owner of a generating unit must determine the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value to determine the voltage ride through requirements for the genera ...
Dual-band Power Amplifier for Wireless Communication
... several classes of operation have been proposed to shape the output voltage and current waveform so that DC power consumption can be minimized. Since output voltage and current waveform can be affected by the termination at both fundamental and harmonic frequencies, some operation modes use harmonic ...
... several classes of operation have been proposed to shape the output voltage and current waveform so that DC power consumption can be minimized. Since output voltage and current waveform can be affected by the termination at both fundamental and harmonic frequencies, some operation modes use harmonic ...
CA‐NLH‐037 NLH 2016 Capital Budget Application Page 1 of 1 Volume III, Tab 19 – Replace Protective Relays
... amplitude compensation can be made in the settings of microprocessor based relays, phase CTs used for protection systems specified in this standard will all be wye connected to the relays. Connecting CTs in wye configurations allow for residual current to be measured where required. The wye configur ...
... amplitude compensation can be made in the settings of microprocessor based relays, phase CTs used for protection systems specified in this standard will all be wye connected to the relays. Connecting CTs in wye configurations allow for residual current to be measured where required. The wye configur ...
SmartWinch - RC
... The recommended battery pack is 5 or 6 NiCad or NimH cells. Alternatively a 6V sealed lead acid gel battery may be used. These days with higher cell energy densities, AA size NiCad or NimH cells can have capacities of up to about 2000 mAh. With these high capacities it is also feasible to use AAA si ...
... The recommended battery pack is 5 or 6 NiCad or NimH cells. Alternatively a 6V sealed lead acid gel battery may be used. These days with higher cell energy densities, AA size NiCad or NimH cells can have capacities of up to about 2000 mAh. With these high capacities it is also feasible to use AAA si ...
Insulation monitoring Vigilohm Merlin Gerin
... c easy mounting in Prisma enclosures using the corresponding mounting plates and front plates that come with the appropriate cut-outs; c the devices are interconnected by shielded cables (double 0.75 mm2 twisted pairs). The resistance between the two most distant points must not exceed 12 Ω. The lea ...
... c easy mounting in Prisma enclosures using the corresponding mounting plates and front plates that come with the appropriate cut-outs; c the devices are interconnected by shielded cables (double 0.75 mm2 twisted pairs). The resistance between the two most distant points must not exceed 12 Ω. The lea ...
Guide to Low Voltage Busbar Trunking Systems Verified to
... A simple way to deal with this issue of additional heat in the conductors is to use a larger neutral conductor. This applies to the whole of the busbar system including affected tap-off units and associated protective devices with a neutral pole. Busbar trunking manufacturers may provide “oversized” ...
... A simple way to deal with this issue of additional heat in the conductors is to use a larger neutral conductor. This applies to the whole of the busbar system including affected tap-off units and associated protective devices with a neutral pole. Busbar trunking manufacturers may provide “oversized” ...
PM1200 power meter - Schneider Electric
... This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
... This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
UNIVERSITY OF ÇUKUROVA INSTITUTE OF NATURAL AND
... A power quality problem is any voltage, current deviations that results in failure or misoperation of customer equipment. There are two classes of power quality problems according to causes. The first class covers voltage sags/swells and momentary interruptions mostly caused by faults in the power s ...
... A power quality problem is any voltage, current deviations that results in failure or misoperation of customer equipment. There are two classes of power quality problems according to causes. The first class covers voltage sags/swells and momentary interruptions mostly caused by faults in the power s ...
Rectifier

A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.