Fourth Edition, last update January 1, 2004 - Iznogood
... Different types of numbers find different application in the physical world. Whole numbers work well for counting discrete objects, such as the number of resistors in a circuit. Integers are needed when negative equivalents of whole numbers are required. Irrational numbers are numbers that cannot be ...
... Different types of numbers find different application in the physical world. Whole numbers work well for counting discrete objects, such as the number of resistors in a circuit. Integers are needed when negative equivalents of whole numbers are required. Irrational numbers are numbers that cannot be ...
The thyristor switched and conventionally switched harmonic filter
... shall be equipped with an internal hinged protective barrier door to guard against inadvertent entry to the terminals of the load-interrupter switch. Access to any portion of the air disconnect switch shall be blocked by the protective door while allowing access to the air disconnect switch and main ...
... shall be equipped with an internal hinged protective barrier door to guard against inadvertent entry to the terminals of the load-interrupter switch. Access to any portion of the air disconnect switch shall be blocked by the protective door while allowing access to the air disconnect switch and main ...
PSoC® 4 Hardware Design Considerations
... PSoC 4100/4200 has two oscillators: an internal main oscillator (IMO), which drives the high-frequency clock (HFCLK), and an internal low-speed oscillator (ILO), which drives the low-frequency clock (LFCLK). The IMO is rated at ±2 percent accuracy. If you need better accuracy, you can bring in a pre ...
... PSoC 4100/4200 has two oscillators: an internal main oscillator (IMO), which drives the high-frequency clock (HFCLK), and an internal low-speed oscillator (ILO), which drives the low-frequency clock (LFCLK). The IMO is rated at ±2 percent accuracy. If you need better accuracy, you can bring in a pre ...
A DC-DC conversion powering scheme for the CMS Phase
... modules, which are very similar to the future ones. AC PIX V8 DC-DC converters provided the required 3.0 V and 2.4 V. Eight DC-DC converters were plugged into a small version of the prototype bus board. The original pixel power supplies and supply cables were used, and the cabling between the DC-DC ...
... modules, which are very similar to the future ones. AC PIX V8 DC-DC converters provided the required 3.0 V and 2.4 V. Eight DC-DC converters were plugged into a small version of the prototype bus board. The original pixel power supplies and supply cables were used, and the cabling between the DC-DC ...
TM 11-6625-828-45 DEPARTMENT OF THE ARMY TECHNICAL
... current (de) output from rectifier V11, filtered by a singlesection choke-input filter, consisting of choke L121 and capacitor C158, is connected in series with series regulator V114. The load current through V114 is dependent on TM 11-6625-4$’ 45 the grid bias applied to ...
... current (de) output from rectifier V11, filtered by a singlesection choke-input filter, consisting of choke L121 and capacitor C158, is connected in series with series regulator V114. The load current through V114 is dependent on TM 11-6625-4$’ 45 the grid bias applied to ...
Datasheet - STMicroelectronics
... When VCC falls below 1 V, the RST (STM809/811) output no longer sinks current, but becomes an open circuit. In most systems this is not a problem, as most MCUs do not operate below 1 V. However, in applications where RST output must be valid down to 0 V, a pull-down resistor may be added to hold the ...
... When VCC falls below 1 V, the RST (STM809/811) output no longer sinks current, but becomes an open circuit. In most systems this is not a problem, as most MCUs do not operate below 1 V. However, in applications where RST output must be valid down to 0 V, a pull-down resistor may be added to hold the ...
NI423 - VeriSTAR
... or pipe, which is placed, in a cathodic protection system, between an anode and adjacent cathode to minimize the risk of hydrogen damage to the latter and to improve current distribution • doubler plate: additional plate used to provide extra strength at a point of anode attachment to a structure • ...
... or pipe, which is placed, in a cathodic protection system, between an anode and adjacent cathode to minimize the risk of hydrogen damage to the latter and to improve current distribution • doubler plate: additional plate used to provide extra strength at a point of anode attachment to a structure • ...
Mounting Instruction
... POSIDRIVE® are electrical components of power electronics for the regulation of energy flow in high-voltage systems. They are exclusively designed to power servo (MDS) and asynchronous (FDS, MDS) machines. Utilization, installation, operation and maintenance are only permitted under observation and ...
... POSIDRIVE® are electrical components of power electronics for the regulation of energy flow in high-voltage systems. They are exclusively designed to power servo (MDS) and asynchronous (FDS, MDS) machines. Utilization, installation, operation and maintenance are only permitted under observation and ...
Microprocessor Supervisory Circuit in 4-Lead SC70 ADM6384
... unconnected. An external push-button switch can be connected between MR and ground so that the user can generate a reset. Debounce circuitry for this purpose is integrated on-chip. Noise immunity is provided on the MR input, and fast, negative-going transients of up to 100 ns (typical) are ignored. ...
... unconnected. An external push-button switch can be connected between MR and ground so that the user can generate a reset. Debounce circuitry for this purpose is integrated on-chip. Noise immunity is provided on the MR input, and fast, negative-going transients of up to 100 ns (typical) are ignored. ...
ASSA ABLOY Door Security Solutions
... 600 lbs. holding force Magnalock with automatic dual voltage. This model offers a built-in wire access chamber and bracket mount design for a unique and simplified method of installation. Recommended for applications where physical assault on the door is not expected, like access controlled interior ...
... 600 lbs. holding force Magnalock with automatic dual voltage. This model offers a built-in wire access chamber and bracket mount design for a unique and simplified method of installation. Recommended for applications where physical assault on the door is not expected, like access controlled interior ...
On-Chip Transient Detection Circuit for System
... power-supply voltage. In order to increase the sensitivity of the detection circuit in Fig. 3(a) and (b) during fast electrical transient under the systemlevel ESD zapping, the device W/L ratios of latch should be well designed. In order to effectively pull down the voltage level at the node B, the ...
... power-supply voltage. In order to increase the sensitivity of the detection circuit in Fig. 3(a) and (b) during fast electrical transient under the systemlevel ESD zapping, the device W/L ratios of latch should be well designed. In order to effectively pull down the voltage level at the node B, the ...
ADM9690 数据手册DataSheet 下载
... The watchdog timer circuit monitors the activity of the microprocessor in order to check that it is not stalled in an infinite loop. An output line on the processor may be used to toggle the Watchdog Input (WDI) line. If this line is not toggled within the selected timeout period, both RESET outputs ...
... The watchdog timer circuit monitors the activity of the microprocessor in order to check that it is not stalled in an infinite loop. An output line on the processor may be used to toggle the Watchdog Input (WDI) line. If this line is not toggled within the selected timeout period, both RESET outputs ...
DS3881 Single-Channel Automotive CCFL Controller General Description Features
... step-up transformer and ground (see the Typical Operating Circuit). The transformer has a center tap on the primary side that is connected to a DC voltage supply. The DS3881 alternately turns on the two MOSFETs to create the high-voltage AC waveform on the secondary side. By varying the duration of ...
... step-up transformer and ground (see the Typical Operating Circuit). The transformer has a center tap on the primary side that is connected to a DC voltage supply. The DS3881 alternately turns on the two MOSFETs to create the high-voltage AC waveform on the secondary side. By varying the duration of ...
Live Tank Circuit Breakers Application Guide
... opening of the breaking units, can be carried out outdoors. However, although the maintenance is relatively simple, certain switching operations (e.g. switching of small inductive currents) require rather frequent maintenance. SF6 gas circuit breakers are superior to these earlier technologies as th ...
... opening of the breaking units, can be carried out outdoors. However, although the maintenance is relatively simple, certain switching operations (e.g. switching of small inductive currents) require rather frequent maintenance. SF6 gas circuit breakers are superior to these earlier technologies as th ...
Aalborg Universitet Sera, Dezso
... In order to detect partial shadows on PV panels, a method based on equivalent thermal voltage (Vt ) monitoring is proposed. Vt is calculated using the simplified three-parameter model, based on experimental curve. The main advantages of the method are the simple expression for Vt , high sensitivity ...
... In order to detect partial shadows on PV panels, a method based on equivalent thermal voltage (Vt ) monitoring is proposed. Vt is calculated using the simplified three-parameter model, based on experimental curve. The main advantages of the method are the simple expression for Vt , high sensitivity ...
Liebert® FS Flywheel Energy Storage System™
... OFF Mode to STARTUP Mode if all startup conditions are met. The DC Flywheel shall also enter OFF Mode at the end of a shutdown and shall transition automatically from SHUTDOWN Mode to OFF Mode. B. Startup Mode - In STARTUP Mode, the DC Flywheel shall charge (increase speed) up to the minimum operati ...
... OFF Mode to STARTUP Mode if all startup conditions are met. The DC Flywheel shall also enter OFF Mode at the end of a shutdown and shall transition automatically from SHUTDOWN Mode to OFF Mode. B. Startup Mode - In STARTUP Mode, the DC Flywheel shall charge (increase speed) up to the minimum operati ...
K9EQ AH-4 Universal Interface User`s Manual
... may not be necessary to adjust power output when tuning. (Note that this feature may or may not work reliably depending upon how stable the rig’s output is for a given audio level.) ...
... may not be necessary to adjust power output when tuning. (Note that this feature may or may not work reliably depending upon how stable the rig’s output is for a given audio level.) ...
ERP Protection Relays Test Technical Teaching Equipment
... Instrumentation, power supplies, power transformers, current transformers, voltage transformers and load resistors are incorporated in the unit and has an user-friendly desk space for users to work on. The relays are housed in modern, portable enclosures. The test unit will support up to two relays ...
... Instrumentation, power supplies, power transformers, current transformers, voltage transformers and load resistors are incorporated in the unit and has an user-friendly desk space for users to work on. The relays are housed in modern, portable enclosures. The test unit will support up to two relays ...
PHASE-COMPARISON CARRIER-PILOT RELAYS
... of internal fault current is reached on transmission lines with up to35 decibels attenuation tothe carrier current. Simultaneous tripping at all line terminals is obtained when the values of the CT secondary currents exceed those listed in Table IV. Refer to Section 03 to determine if tripping requi ...
... of internal fault current is reached on transmission lines with up to35 decibels attenuation tothe carrier current. Simultaneous tripping at all line terminals is obtained when the values of the CT secondary currents exceed those listed in Table IV. Refer to Section 03 to determine if tripping requi ...
Rectifier

A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.