MAX6340/ MAX6421–MAX6426 Low-Power, SC70/SOT µP Reset Circuits with Capacitor-Adjustable Reset Timeout Delay
... When VCC falls below 1V, RESET/RESET current-sinking (sourcing) capabilities decline drastically. In the case of the MAX6421/MAX6424, high-impedance CMOS-logic inputs connected to RESET can drift to undetermined voltages. This presents no problems in most applications, since most µPs and other circu ...
... When VCC falls below 1V, RESET/RESET current-sinking (sourcing) capabilities decline drastically. In the case of the MAX6421/MAX6424, high-impedance CMOS-logic inputs connected to RESET can drift to undetermined voltages. This presents no problems in most applications, since most µPs and other circu ...
CMOS VLSI Design: A Circuits and Systems Perspective
... Cover Printer: Lehigh-Phoenix Color/Hagerstown ...
... Cover Printer: Lehigh-Phoenix Color/Hagerstown ...
70B-ROP-2002-Recommended Practice for Electrical
... diagrams discussed in the following paragraphs are some of those in common use. 4-2.3.1. Single-line diagrams show the electrical circuitry down to, and often including, the major items of utilization equipment. They should show all electrical equipment in the power system and give all pertinent rat ...
... diagrams discussed in the following paragraphs are some of those in common use. 4-2.3.1. Single-line diagrams show the electrical circuitry down to, and often including, the major items of utilization equipment. They should show all electrical equipment in the power system and give all pertinent rat ...
64-0007 Rev E - Magnum Dimensions
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
Electrical Engineering Objective Type Questions
... (b) the brushes of same polarity should track each other (c) brush position has no effect on the commutator grooving Ans: a 79. The following constitute short-circuit in the armature winding. (a) Insulation failure between two com-mutator bars (6) Insulation failure between two turns of a coil (c) T ...
... (b) the brushes of same polarity should track each other (c) brush position has no effect on the commutator grooving Ans: a 79. The following constitute short-circuit in the armature winding. (a) Insulation failure between two com-mutator bars (6) Insulation failure between two turns of a coil (c) T ...
Unidrive SP UserGuide
... Control Techniques is committed to minimising the environmental impacts of its manufacturing operations and of its products throughout their life cycle. To this end, we operate an Environmental Management System (EMS) which is certified to the International Standard ISO 14001. Further information on ...
... Control Techniques is committed to minimising the environmental impacts of its manufacturing operations and of its products throughout their life cycle. To this end, we operate an Environmental Management System (EMS) which is certified to the International Standard ISO 14001. Further information on ...
MS Series Owner`s Manual
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
MAX6826 Dual Ultra-Low-Voltage SOT23 µP Supervisors with Manual Reset and Watchdog Timer
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
- Magnum Dimensions
... To prevent a spark at the battery and reduce the chance of explosion, always connect the cables to the batteries first. Then connect the cables to the inverter. ...
... To prevent a spark at the battery and reduce the chance of explosion, always connect the cables to the batteries first. Then connect the cables to the inverter. ...
Applications for SIPROTEC Protection Relays
... Switchover with redundant incoming feeders means investment. However, by considering the behavior in case of outages of equipment, the system topology, the protection concepts, the system capacity utilization (supply and loads) and the method of operation, even more reliable and safe system operatio ...
... Switchover with redundant incoming feeders means investment. However, by considering the behavior in case of outages of equipment, the system topology, the protection concepts, the system capacity utilization (supply and loads) and the method of operation, even more reliable and safe system operatio ...
Field Control I/O Modules User`s Manual
... only one wire, there are five extra tie point terminals for each I/O module position. The maximum current through any one terminal is 10 Amps. (These extra terminals are not available with the barrier-style I/O Terminal Block, which can accommodate up to two wires per terminal). ...
... only one wire, there are five extra tie point terminals for each I/O module position. The maximum current through any one terminal is 10 Amps. (These extra terminals are not available with the barrier-style I/O Terminal Block, which can accommodate up to two wires per terminal). ...
PowerNet MIB Reference Guide
... The original of this agreement has been written in English. The parties hereto waive any statute, law, or regulation that might provide an alternative law or forum or to have this agreement written in any language other than English. Any translation of this agreement to a language other than English ...
... The original of this agreement has been written in English. The parties hereto waive any statute, law, or regulation that might provide an alternative law or forum or to have this agreement written in any language other than English. Any translation of this agreement to a language other than English ...
PVI 23TL PVI 28TL INSTALLATION AND OPERATION MANUAL
... with ungrounded (floating) PV arrays only. By following this manual the inverter can be installed and operated safely. This installation guide is used as a reference for commissioning and as a guideline on how to use the inverter most effectively. Feeding power back to the grid involves conversion o ...
... with ungrounded (floating) PV arrays only. By following this manual the inverter can be installed and operated safely. This installation guide is used as a reference for commissioning and as a guideline on how to use the inverter most effectively. Feeding power back to the grid involves conversion o ...
Intel® Atom™ Processor D400/D500 Series Datasheet, Vol. 1
... Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whats ...
... Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whats ...
ECODRIVE03 Drive Controllers
... Storable energy in the bus ....................................................................................................... 5-9 Mains supply options ............................................................................................................. 5-10 Allowed DC bus Peak Power ... ...
... Storable energy in the bus ....................................................................................................... 5-9 Mains supply options ............................................................................................................. 5-10 Allowed DC bus Peak Power ... ...
64-0032 Rev B (MS-PAE Series).indd
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
... This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is ...
Sure Cross DXM100-Bx Wireless Controller Instruction Manual
... 4.4 Modbus Registers - Internal Local Registers (Modbus Slave 199) ...
... 4.4 Modbus Registers - Internal Local Registers (Modbus Slave 199) ...
64-0071 Rev A (ME-G Series).indd
... • This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. • Use insulated tools to reduce the chance of electrical shock or accidental short circuits. • There are no user-serviceable parts contained in this product. • This ...
... • This product is designed for indoor/compartment installation. It must not be exposed to rain, snow, moisture, or liquids of any type. • Use insulated tools to reduce the chance of electrical shock or accidental short circuits. • There are no user-serviceable parts contained in this product. • This ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.